8,277 research outputs found
Self-aligning fixture used in lathe chuck jaw refacing
Self-aligning tool positions and rigidly holds lathe chuck jaws for refacing and truing of the clamping surface. The jaws clamp the fixture in the manner of clamping a workpiece. The fixture can be modified to accommodate four-jawed checks
Variation propagation of bench vises in multi-stage machining processes
Comunicación presentada a MESIC 2019 8th Manufacturing Engineering Society International Conference (Madrid, 19-21 de Junio de 2019)Variation propagation has been successfully modeled by the Stream of Variation (SoV) approach in multistage machining processes. However, the SoV model basically supports 3-2-1 fixtures based on punctual locators and other workholding systems such as conventional vises are not considered yet. In this paper, the SoV model is expanded to include the fixture- and datum-induced variations on workholding devices such as bench vises. The model derivation is validated through assembly and machining simulations on Computer Aided Design software. The case study analyzed shows an average error of part quality prediction between the SoV model and the CAD simulations of 0.26%
Contact mechanics applied to the machining of thin rings
Precision machining of thin rings is of key importance in the performance of many mechanical components such as bearings, rings, turbines, etc. An important factor to take into account is to know the influence of the clamping forces values at different angular positions of the workpiece in the geometrical tolerances after machining. The lower the clamping force, better tolerances will be achieved, but with the disadvantage of reducing friction force and, therefore, increasing the risk of slipping. Therefore, achieving a minimum but safe clamping force is a key factor to control the process. This paper presents some contributions of contact mechanics to the determination of an optimum clamping force. A subsequent methodology is applied that takes into account model of bulk deformation and local contact stresses and experimental data with the object of obtain the optimum torque applied to the chuck.The authors would like to thank the Basque Government for supporting this work made under the ETORTEK Program within the MARGUNE CRC framework while the first author was a visiting professor at TECNUN
Terminal guidance sensor system
A system is described for guiding a claw to the proper distance and into the proper orientation in yaw and pitch, to engage a grappling fixture. The system includes four proximity sensors on the claw, that are arranged at corners of an imaginary square, which sense the distance to the top surface of the grappling fixture. If a pair of sensors at opposite corners of the square sense a different distance to the top surface of the grappling fixture, then it is known that the claw is rotated about a corresponding axis with respect to the plane of the grappling fixture
Fem and Von Mises analysis of OSSTEM ® dental implant structural components: evaluation of different direction dynamic loads
Abstract
PURPOSE:
The objective of this investigation is to study prosthodontics and internal components resistance to the masticatory stress and considering different force directions by using Finite Element Method analysis (FEM). The structural materials of the components are usually Titanium alloy grade 4 or 5 and thus, guarantee the integration of the fixture in the bone due to the osteointegration phenomena. Even if the long-term dental implant survival rate is easy to be obtained and confirmed by numerous researches, the related clinical success, due to the alteration of the mechanical and prosthodontics components is still controversial.
METHODS:
By applying engineering systems of investigations like FEM and Von Mises analyses, it has been investigated how dental implant material was held against the masticatory strength during the dynamic masticatory cycles. A three-dimensional system involved fixture, abutment and the connection screws, which were created and analyzed. The elastic features of the materials used in the study were taken from recent literature data.
RESULTS:
Data revealed a different response for both types of devices, although implant neck and dental abutment showed better results for all conditions of loading while the abutment screw represented aweak point of the system.
CONCLUSION:
The data of this virtual model showed all the features of different prosthetic retention systems under the masticatory load. Clinicians should find better prosthetic balance in order to better distribute the stress over the component and to guarantee patients' clinical long-term results
A ball trunnion capture latch
The Ball Trunnion Capture Latch described was developed and designed to restrain a spacecraft deployable appendage in three translational directions. The latch is capable of supporting an appendage during STS ascent and landing events and is capable of releasing and restowing an appendage distorted in three translational directions by thermal growth. The requirements, design, analyses, and tests conducted on a development unit of the latch are discussed
Use of long implants with distal anchorage in the skull base for treatment of extreme maxillary atrophy : the remote bone anchorage concept
The objectives of this study are to present a new concept of the bone anchorage using long implants in remote bone sites and to discuss four cases treated with this method. Our patients were treated with long implants with a distant anchorage in the skull bone. The planning procedure, the construction of the drill guide, and the surgical protocol are described. In the clinical cases described, all four patients were rehabilitated with the remote bone anchorage concept using long implants anchored in the skull base. Patients were followed for 5 - 12 years and the implants remained present and stable in these time periods. The skull base implant is a new concept of bone anchorage using long implants. It can be a solution for complicated clinical situations (often failed bone reconstructions and implant placements) or an alternative for bone grafting and maxillary augmentation procedures. There is effective implant retention in the skull base, an anatomical area that is often overlooked for implant placement
Stable fixation of an osseointegated implant system for above-the-knee amputees: titel RSA and radiographic evaluation of migration and bone remodeling in 55 cases.
Background and purposeRehabilitation of patients with transfemoral amputations is particularly difficult due to problems in using standard socket prostheses. We wanted to assess long-term fixation of the osseointegrated implant system (OPRA) using radiostereometric analysis (RSA) and periprosthetic bone remodeling.Methods51 patients with transfemoral amputations (55 implants) were enrolled in an RSA study. RSA and plain radiographs were scheduled at 6 months and at 1, 2, 5, 7, and 10 years after surgery. RSA films were analyzed using UmRSA software. Plain radiographs were graded for bone resorption, cancellization, cortical thinning, and trabecular streaming or buttressing in specifically defined zones around the implant.ResultsAt 5 years, the median (SE) migration of the implant was -0.02 (0.06) mm distally. The rotational movement was 0.42 (0.32) degrees around the longitudinal axis. There was no statistically significant difference in median rotation or migration at any follow-up time. Cancellization of the cortex (plain radiographic grading) appeared in at least 1 zone in over half of the patients at 2 years. However, the prevalence of cancellization had decreased by the 5-year follow-up.InterpretationThe RSA analysis for the OPRA system indicated stable fixation of the implant. The periprosthetic bone remodeling showed similarities with changes seen around uncemented hip stems. The OPRA system is a new and promising approach for addressing the challenges faced by patients with transfemoral amputations
Tensile strength testing device Patent
Tensile strength testing device having pulley guides for exerting multiple forces on test specime
- …