Investigation of photoplethysmographic signals and blood oxygen saturation values on healthy volunteers during cuff-induced hypoperfusion using a multimode PPG/SpO2 sensor
Photoplethysmography (PPG) is a technique widely used to monitor volumetric blood changes induced by cardiac pulsations. Pulse oximetry uses the technique of PPG to estimate arterial oxygen saturation values (SpO2). In poorly perfused tissues, SpO2 readings may be compromised due to the poor quality of the PPG signals. A multimode finger PPG probe that operates simultaneously in reflectance, transmittance and a combined mode called “transreflectance”’ was developed, in an effort to improve the quality of the PPG signals in states of hypoperfusion. Experiments on 20 volunteers were conducted to evaluate the performance of the multimode PPG sensor and compare the results with a commercial transmittance pulse oximeter. A brachial blood pressure cuff was used to induce artificial hypoperfusion. Results showed that the amplitude of the transreflectance AC PPG signals were significantly different (p\0.05) than the AC PPG signals obtained from the other two conventional PPG sensors (reflectance and transmittance). At induced brachial pressures between 90 and 135 mmHg, the reflectance finger pulse oximeter failed 25 times (failure rate 42.2 %) to estimate SpO2 values, whereas the transmittance pulse oximeter failed 8 times (failure rate 15.5 %). The transreflectance pulse oximeter failed only 3 times (failure rate 6.8 %) and the commercial pulse oximeter failed 17 times (failure rate 29.4 %)
Recommended from our members
Investigation of pulse oximeter failure rates during artificial hypoperfusion utilising a custom made multimode pulse oximetery sensor
Pulse oximetry utilises the technique of photople-thysmography (PPG) to estimate arterial oxygen saturation values (SpO2). In poorly perfused tissues, SpO2 readings may be compromised due to the poor quality of the PPG signals. In order to investigate further the threshold where pulse oximetry fails to produce accurate SpO2 values, we have developed a custom made multimode finger pulse oximetry probe that operates in conventional, reflectance and transmittance mode independently and also in a combined mode called transreflectance. Experiments on twenty healthy volunteers undergoing induced artificial hypoperfusion utilising a brachial blood pressure cuff were performed in order to investigate the possible threshold of failure to accurately estimate SpO2 values from all pulse oximetry modes. The results suggest that the transreflectance pulse oximeter endures more in estimating accurately SpO2 values when compared with the other two custom made pulse oximeters and a commercial finger pulse oximeter
Recommended from our members
Evaluation of a multimode photoplethysmographic sensor during cuff-induced hypoperfusion
Abstract—Photoplethysmography (PPG) is a technique widely used to monitor volumetric blood changes induced by cardiac pulsations. Pulse oximetry uses the technique of PPG to estimate arterial oxygen saturation values(SpO2). In poorly perfused tissues, SpO2 readings may be compromised due to the poor quality of the PPG signals. We have developed a new multimode PPG measurement system which utilizes a reflectance PPG probe that operates in reflectance, transmittance and transreflectance mode simultaneously aiming to improve the quality of the PPG signals in cases of poor peripheral perfusion. In order to evaluate the performance of the probe, experiments were performed in healthy volunteers. A blood pressure cuff was used to induce systematic and controlled artificial hypoperfusion while PPG signals were recorded using all three modes. It was found that the amplitude of the transreflectance signal was significantly greater than the other two conventional PPG sensors at all occlusion pressures, suggesting the potential for improved signal acquisition in patients with peripheral hypoperfusion
Recommended from our members
Photoplethysmographic signals and blood oxygen saturation values during artificial hypothermia in healthy volunteers
Pulse oximetry utilizes the technique of photoplethysmography to estimate arterial oxygen saturation (SpO2) values. During hypothermia, the amplitude of the photoplethysmograph (PPG) is compromised which can lead to inaccurate estimation of SpO2. A new mutlimode PPG/pulse oximeter sensor was developed to investigate the behaviour of PPGs during conditions of induced hypothermia (hand immersed in an ice bath). PPG measurements from 20 volunteers were conducted and SpO2 values were estimated at all stages of the experiment. Good quality PPG signals were observed from the majority of the volunteers at almost all hand temperatures. At low temperature ranges, from 13 to 21 ◦C, the failure rate to estimate SpO2 values from the multimode transreflectance PPG sensor was 2.4% as compared to the commercial pulse oximeter with a failure rate of 70%
Recommended from our members
Accuracy of reflectance photoplethysmography on detecting cuff-induced vascular occlusions
Photoplethysmography (PPG) is a noninvasive optical technique, which can also be used to derive important parameters other than arterial oxygen saturation (SpO2). In this work, the accuracy of the technique on detecting changes in blood perfusion during different levels of vascular occlusions has been explored. A dual-wavelength, reflectance PPG probe was applied on the left forearm of 10 healthy volunteers and raw PPG signals were acquired by a research PPG processing system. The raw PPG signals were separated into pulsatile AC and continuous DC PPG components. The signals were used to estimate SpO2 and changes in concentration of oxygenated, deoxygenated, and total haemoglobin. Different levels of occlusions, from 20 mmHg to total occlusion were induced by a pressure-cuff on the left arm. The system was able to indicate all the occlusions. In particular, the haemoglobin concentration changes estimated from PPG were in high agreement with Near Infrared Spectroscopy measurements
Recommended from our members
Reflectance Photoplethysmography as Non-Invasive Monitoring of Tissue Blood Perfusion.
In the last decades Photoplethysmography (PPG) has been used as noninvasive technique for monitoring arterial oxygen saturation by Pulse Oximetry (PO), whereas Near Infrared Spectroscopy (NIRS) has been employed for monitoring tissue blood perfusion. While NIRS offers more parameters to evaluate oxygen delivery and consumption in deep tissues, PO only assesses the state of oxygen delivery. For a broader assessment of blood perfusion, this paper explores the utilization of dual-wavelength PPG by using the pulsatile (AC) and continuous (DC) PPG for the estimation of arterial oxygen saturation (SpO2) by conventional PO. Additionally, the Beer-Lambert law is applied to the DC components only for the estimation of changes in deoxy-hemoglobin (HHb), oxy-hemoglobin (HbO2) and total hemoglobin (tHb) as in NIRS. The system was evaluated on the forearm of 21 healthy volunteers during induction of venous occlusion (VO) and total occlusion (TO). A reflectance PPG probe and NIRS sensor were applied above the brachioradialis, PO sensors were applied on the fingers, and all the signals were acquired simultaneously. While NIRS and forearm SpO2 indicated VO, SpO2 from the finger did not exhibit any significant drop from baseline. During TO all the indexes indicated the change in blood perfusion. HHb, HbO2 and tHb changes estimated by PPG presented high correlation with the same parameters obtained by NIRS during VO (r2=0.960, r2=0.821 and r2 =0.974 respectively) and during TO (r2=0.988, r2=0.940 and r2=0.938 respectively). The system demonstrated the ability to extract valuable information from PPG signals for a broader assessment of tissue blood perfusion
Recommended from our members
Photoplethysmography for blood volumes and oxygenation changes during intermittent vascular occlusions
Photoplethysmography (PPG) is an optical technique that measures blood volume variations. The main application of dual-wavelength PPG is pulse oximetry, in which the arterial oxygen saturation (SpO[Formula: see text]) is calculated noninvasively. However, the PPG waveform contains other significant physiological information that can be used in conjunction to SpO[Formula: see text] for the assessment of oxygenation and blood volumes changes. This paper investigates the use of near infrared spectroscopy (NIRS) processing techniques for extracting relative concentration changes of oxygenated ([Formula: see text]HbO[Formula: see text]), reduced ([Formula: see text]HHb) and total haemoglobin ([Formula: see text]tHb) from dual-wavelength PPG signals during intermittent pressure-increasing vascular occlusions. A reflectance PPG sensor was attached on the left forearm of nineteen (n = 19) volunteers, along with a reference NIRS sensor positioned on the same forearm, above the left brachioradialis. The investigation protocol consisted of seven intermittent and pressure-increasing vascular occlusions. Relative changes in haemoglobin concentrations were obtained by applying the modified Beer-Lambert law to PPG signals, while oxygenation changes were estimated by the difference between red and infrared attenuations of DC PPGs (A[Formula: see text] = [Formula: see text]A[Formula: see text] - [Formula: see text]A[Formula: see text]) and by the conventional SpO[Formula: see text]. The [Formula: see text]HbO[Formula: see text], [Formula: see text]HHb, [Formula: see text]tHb from the PPG signals indicated significant changes in perfusion induced by either partial and complete occlusions (p < 0.05). The trends in the variables extracted from PPG showed good correlation with the same parameters measured by the reference NIRS monitor. Bland and Altman analysis of agreement between PPG and NIRS showed underestimation of the magnitude of changes by the PPG. A[Formula: see text] indicated significant changes for occlusion pressures exceeding 20 mmHg (p < 0.05) and correlation with tissue oxygenation changes measured by NIRS, while SpO[Formula: see text] had significant changes after 40 mmHg (p < 0.05). Relative changes in haemoglobin concentrations can be estimated from PPG signals and they showed a good level of accuracy in the detection of perfusion and oxygenation changes induced by different degrees of intermittent vascular occlusions. These results can open up to new applications of the PPG waveform in the detection of blood volumes and oxygenation changes
Recommended from our members
Intra-operative optical monitoring of bowel tissue viability based on photoplethysmography and laser doppler flowmetry
Determination of bowel viability in patients undergoing bowel resection is essential in gastrointestinal surgery. One of the most common operations in gastrointestinal surgery is bowel resection for patients who have different kinds of bowel cancer or any other occlusion in which anastomosis has to be carried out following the removal of an unhealthy segment of the bowel. Monitoring blood flow in abdominal surgery especially intraoperatively would be a valuable tool for prevention of a postoperative anastomosis complication (e.g. anastomotic leak, which is the main complication after colorectal resection).
The development of a continuous method for monitoring perfusion of bowel tissue would assist in early detection of inadequate blood supply which then help to reduce the occurrence of an anastomosis complication. Although various monitoring techniques have been proposed to assess intestinal viability intraoperatively, none of these techniques have proved to be reliable enough to replace visual observation. Therefore, to date there is no widely accepted and readily available intraoperative technique to reliably assess the viability of bowel tissue.
The aim of this study was to combine the established techniques, laser Doppler flowmetry (LDF) and Photoplethysmography (PPG), into one probe intended for assessment of perfusion in abdominal tissue during bowel resection intraoperatively. In PPG, changes in transmission of light through tissue due to pulsation of small arteries can be monitored whereas in LDF microcirculatory blood cell velocity and flux can be studied. Such a probe could alert the surgeon immediately of any compromise in blood flow so further investigation and, if necessary, therapeutic steps can be applied immediately to prevent severe consequences. Therefore, custom reflectance PPG along with LDF sensor was designed and built in the form of a probe to investigate the changes in blood volume, blood flow and arterial oxygen saturation in patients undergoing bowel resection.
The instrumentation was designed successfully and the data was saved for the further analysis. Twenty-four patients undergoing bowel resection were recruited for monitoring of perfusion and blood flowintraoperatively; twenty had undergone laparoscopy and the remainder had a laparotomy operation. Eight different measurements were performed during each trial. The results revealed that the probe could be an indicator of evaluating perfusion and blood flow changes at different stages of the surgery. The results also suggest that laser Doppler is more sensitive to artefact compared to PPG. Differences in amplitude of PPG between different measurements reveal that the sensor does detect changes in blood volume and flow confirming that it has the ability to verify that pulsatile flow is being preferentially preserved at the last step of the resection procedure (at the edges of the anastomosis sites after anastomosis is been constructed
Recommended from our members
In vivo investigations of photoplethysmograms and arterial oxygen saturation from the auditory canal in conditions of compromised peripheral perfusion
Pulse oximeters rely on the technique of photoplethysmography (PPG) to estimate arterial oxygen saturation (SpO2). In conditions of poor peripheral perfusion such as hypotension, hypothermia, and vasoconstriction, the PPG signals detected are often small and noisy, or in some cases unobtainable. Hence, pulse oximeters produce erroneous SpO2 readings in these circumstances. The problem arises as most commercial pulse oximeter probes are designed to be attached to peripheral sites such as the finger or toes, which are easily affected by vasoconstriction. In order to overcome this problem, the ear canal was investigated as an alternative site for measuring reliable SpO2 on the hypothesis that blood flow to this central site is preferentially preserved. Novel miniature ear canal PPG sensors were developed along with a state of the art PPG processing unit and a data acquisition system to allow for PPG measurements from different depths and surfaces of the ear canal. A preliminary in vivo investigation on seven healthy volunteers has revealed that good quality PPG signals with high amplitude can be obtained from the posterior surface of the outer ear canal. Based on these observations, a second prototype probe suitable for acquisition of PPGs from the posterior surface of the outer ear canal was developed. A pilot study was then carried out on 15 healthy volunteers to validate the feasibility of measuring PPGs and SpO2 from the ear canal in conditions of induced local peripheral vasoconstriction (right hand immersion in ice water). The PPG signals acquired from the ear canal probe were compared with those obtained simultaneously from finger probes attached to the left and the right index fingers. Significant drop (p 45%) and right (> 50%) index fingers during the ice water immersion, while good quality PPG signals with relatively constant amplitude were obtained from the ear canal. Also, the SpO2 values showed that the ear canal pulse oximeter performed better than the two finger pulse oximeters (mean failure rate 30%). A second in vivo investigation was carried out in 15 healthy volunteers, where hypoperfusion was induced more naturally by exposing the volunteer to cold temperatures of 10C for 10min. Normalised Pulse Amplitude (NPA) and SpO2 was calculated from the PPG signals acquired from the ear canal, the finger and the earlobe. By the end of the cold exposure, a mean drop of > 80% was found in the NPA of finger PPGs. The % drop in the NPA of red and infrared earlobe PPG signals was 20% and 26% respectively. Contrarily to both these sites, the NPA of the ear canal PPGs had only dropped by 0.2% and 13% respectively. The SpO2 estimated from the finger sensor was below 90% in 5 volunteers (failure) by the end of the cold exposure. The earlobe pulse oximeter failed in 3 volunteers. The ear canal sensor on the other hand had only failed in 1 volunteer. These results strongly suggest that the ear canal may be used as a suitable alternative site for reliable monitoring of PPGs and SpO2 in cases of compromised peripheral perfusion
Recommended from our members
Reflectance photoplethysmography for non-invasive monitoring of tissue perfusion
Monitoring blood perfusion and oxygenation changes is of vital importance and for this reason many different techniques have been developed over the decades. Photoplethysmography (PPG) is an optical technique that measures blood volume variations in vascular tissue and it is well known for its utilisation in pulse oximetry for the estimation of arterial blood oxygen saturation (SpO2). In pulse oximetry, mainly the pulsatile component of the signal (AC PPG) is used while the continuous DC component is mostly excluded. Near Infrared Spectroscopy (NIRS) is another optical technique that measures changes in the concentration of oxygenated (ΔHbO2), deoxygenated (ΔHHb), and total haemoglobin (ΔtHb) from the variations in light attenuations at different wavelengths.
The main motivation of this research is to explore the capability of Photoplethysmography in assessing tissue perfusion and oxygenation similarly as NIRS. The hypothesis underlining this research is that the DC component of the PPG signal contains information on the overall absorbed light and this part of the PPG signal, acquired at least two wavelengths, may be used to obtain ΔHbO2, ΔHHb, and ΔtHb as performed in NIRS. Therefore, DC PPG attenuations may be related to haemoglobin concentrations by the modified Beer-Lambert law (MBLL). In order to investigate this, novel reflectance, custom-made PPG sensors and measurement systems, including advanced signal processing algorithms, have been developed for the acquisition and analysis of raw PPG signals (AC + DC) from different anatomical locations.
Three in vivo studies on healthy volunteers were carried out in order to investigate if ΔHbO2, ΔHHb, and ΔtHb estimated from PPG could indicate changes in blood perfusion and oxygenation. The studies consisted of vascular occlusions on the forearm, negative bed tilting, and whole body cold exposure. Raw PPG signals were acquired from different locations such as the forearm, fingers, and forehead, whereas simultaneous NIRS signals were used as a reference. The results showed that ΔHbO2, ΔHHb, and ΔtHb could be effectively estimated from PPG signals. These parameters indicated the changes in blood volumes and/or oxygenation, whereas comparison with NIRS signals showed good levels of correlation and trending. These promising results showed that DC PPG signals could be used to monitor changes in blood perfusion and oxygenation, extending the range of applications of Photoplethysmography