75,233 research outputs found
Comparison between flying capacitor and modular multilevel inverter
The paper describes the operational principle of flying capacitor and modular multilevel inverters. The detailed discussions of dc link capacitors voltage balancing methods for both inverters are given in order to enable fair comparison. The causes of dc link capacitors voltage imbalance in flying capacitor multilevel inverter with more than three levels are highlighted. Computer simulation is used to compare the performance of both inverters under several operating conditions
Power loss investigation in HVDC for cascaded H-bridge multilevel inverters (CHB-MLI)
In the last decade, the use of voltage-source multilevel inverters in industrial and utility power applications has been increased significantly mainly due to the many advantages of multilevel inverters, compared to conventional two level inverters. These advantages include: 1) higher output voltage at low switching frequency, 2) low voltage stress (dv/dt), 3) lower total harmonic distortion (THD), 4) less electro-magnetic interference (EMI), 5) smaller output filter, and 6) higher fundamental output. However, the computation of multilevel inverter power losses is much more complicated compared to conventional two level inverters. This paper presents a detailed investigation of CHB-MLI losses for HVDC. Different levels, and IGBT switching devices have been considered in the study. The inverter has been controlled using selective harmonic elimination in which the switching angles were determined using the Genetic Algorithm (GA). MATLAB-SIMULINK is used for the modelling and simulation. This investigation should result in a deeper knowledge and understanding of the performance of CHB-MLI using different IGBT switching devices
Overview of three-phase inverter topologies for distributed generation purposes
The increasing presence of single-phase distributed generators and unbalanced loads in the electric power system may lead to unbalance of the three phase voltages, resulting in increased losses and heating. Distribution network operators are seeking to install larger DG units (viz. kVA in Belgium) by means of three-phase connections instead of single-phase to reduce voltage unbalance. There are several possible topologies to connect the DG units to the three-phase distribution network. These topologies can be divided into three groups: the three-phase three-wire inverters, the three-phase four-wire inverters and the multilevel inverters. In this paper, an overview of the aforementioned topologies is given
Improving the Performance of Low Voltage Networks by an Optimized Unbalance Operation of Three-Phase Distributed Generators
This work focuses on using the full potential of PV inverters in order to improve the efficiency of low voltage networks. More specifically, the independent per-phase control capability of PV three-phase four-wire inverters, which are able to inject different active and reactive powers in each phase, in order to reduce the system phase unbalance is considered. This new operational procedure is analyzed by raising an optimization problem which uses a very accurate modelling of European low voltage networks. The paper includes a comprehensive quantitative comparison of the proposed strategy with two state-of-the-art methodologies to highlight the obtained benefits. The achieved results evidence that the proposed independent per-phase control of three-phase PV inverters improves considerably the network performance contributing to increase the penetration of renewable energy sources.Ministerio de Economía y Competitividad ENE2017-84813-R, ENE2014-54115-
Parameter Optimisation of a Virtual Synchronous Machine in a Microgrid
Parameters of a virtual synchronous machine in a small microgrid are
optimised. The dynamical behaviour of the system is simulated after a
perturbation, where the system needs to return to its steady state. The cost
functional evaluates the system behaviour for different parameters. This
functional is minimised by Parallel Tempering. Two perturbation scenarios are
investigated and the resulting optimal parameters agree with analytical
predictions. Dependent on the focus of the optimisation different optima are
obtained for each perturbation scenario. During the transient the system leaves
the allowed voltage and frequency bands only for a short time if the
perturbation is within a certain range.Comment: 17 pages, 5 figure
Precise modelling of switching and conduction losses in cascaded h-bridge multilevel inverters
Nowadays, voltage source multilevel inverters are being used extensively in industry due to its many advantages, compared to conventional two level inverters, such as higher output voltage at low switching frequency, low voltage stress(dv/dt), lower total harmonic distortion (THD), less electro-magnetic interference (EMI), smaller output filter and higher fundamental output. However, the evaluation of multilevel inverter losses is much more complicated compared to two level inverters. This paper proposes an on-line model for precise calculation of conduction and switching losses for cascaded h-bridge multilevel inverter. The model is simple and efficient and gives clear process of loss calculation. A singlephase 7-level cascaded h-bridge with IGBT's as switching devices has been used as a case study of the proposed model. The inverter has been controlled using selective harmonic elimination in which the switching angles were determined using the Genetic Algorithm (GA). MATLAB-SIMULINK is used for the modelling and simulation
A voltage-source inverter for microgrid applications with an inner current control loop and an outer voltage control loop
Distributed generation (DG) units are commonly inter-faced to the grid by using voltage-source inverters (VSI’s). Extension of the control of these inverters allows to improve the power quality if the main power grid is disturbed or disconnected. In this paper, a control technique is developed for a VSI working in island mode. The control technique is designed in the time domain, combining an inner current control loop with an outer voltage control loop. Voltage regulation under various linear and non-linear load disturbances is studied
A Control Method for Static VAR Compensator Based On Modular Multilevel Inverter
Multilevel inverters are promised to provide a better performance in high power applications such as static VAR compensators. The proposed modular inverter has advantages compared to the conventional technologies. A control system of static VAR compensator using new modular multilevel inverter is proposed in this paper. Modeling and dynamic performance of static VAR compensator based on the proposed multilevel inverter are described in this paper. The inverter switching devices are switched at the fundamental output frequency. How to control the dc capacitor voltage is described. Several simulated results are included to verify the proposed concept. Keywords: Multilevel, inverter, STATCO
- …