Computerized Analysis of Magnetic Resonance Images to Study Cerebral Anatomy in Developing Neonates
The study of cerebral anatomy in developing neonates is of great importance for
the understanding of brain development during the early period of life. This
dissertation therefore focuses on three challenges in the modelling of cerebral
anatomy in neonates during brain development. The methods that have been
developed all use Magnetic Resonance Images (MRI) as source data.
To facilitate study of vascular development in the neonatal period, a set of image
analysis algorithms are developed to automatically extract and model cerebral
vessel trees. The whole process consists of cerebral vessel tracking from
automatically placed seed points, vessel tree generation, and vasculature
registration and matching. These algorithms have been tested on clinical Time-of-
Flight (TOF) MR angiographic datasets.
To facilitate study of the neonatal cortex a complete cerebral cortex segmentation
and reconstruction pipeline has been developed. Segmentation of the neonatal
cortex is not effectively done by existing algorithms designed for the adult brain
because the contrast between grey and white matter is reversed. This causes pixels
containing tissue mixtures to be incorrectly labelled by conventional methods. The
neonatal cortical segmentation method that has been developed is based on a novel
expectation-maximization (EM) method with explicit correction for mislabelled
partial volume voxels. Based on the resulting cortical segmentation, an implicit
surface evolution technique is adopted for the reconstruction of the cortex in
neonates. The performance of the method is investigated by performing a detailed
landmark study.
To facilitate study of cortical development, a cortical surface registration algorithm
for aligning the cortical surface is developed. The method first inflates extracted
cortical surfaces and then performs a non-rigid surface registration using free-form
deformations (FFDs) to remove residual alignment. Validation experiments using
data labelled by an expert observer demonstrate that the method can capture local
changes and follow the growth of specific sulcus
Recommended from our members
Optimal Correction of The Slice Timing Problem and Subject Motion Artifacts in fMRI
Functional magnetic resonance imaging (fMRI) is an extremely popular investigative and clinical imaging tool that allows safe and noninvasive study of the functional living brain. Fundamentally, fMRI measures a physiological signal as it changes over time. The manner in which this spatio-temporal signal is acquired can create technical challenges during image reconstruction that must be corrected for if any meaningful information is to be extracted from the data. Two particular challenges that are fundamentally intertwined with each other are temporal misalignment and spatial misalignment. Temporal misalignment is due to the nature of fMRI acquisition protocols themselves: a 3D volume is created by sampling and stacking multiple 2D slices. However, these slices are not acquired simultaneously or sequentially, and therefore will always be temporally misaligned with each other. Spatial misalignment arises when subject motion is present during the scan, resulting in individual volumes being spatially misaligned with each other. Spatial and temporal misalignment are not independent from each other, and their interaction can cause additional artifacts and reconstruction challenges if not addressed properly.
The purpose of this thesis is to critically examine the problem of both spatial and temporal misalignment from a signal processing perspective, while considering the physical nature and origin of the signal itself, and develop optimal correction routines for spatial and temporal misalignment and their associated artifacts.
One of the most immediate problems associated with temporal misalignment is that the order in which the slices are acquired must be known in order for correction to be possible. Surprisingly, this information is rarely provided with old or shared data, meaning that this critical preprocessing step must be skipped, significantly lowering the value of the data. We use the spatio-temporal properties of the fMRI signal to develop a robust and accurate algorithm to infer the slice acquisition order retrospectively from any fMRI scan. The ability to extract the interleave parameter from any data set allows us to perform slice timing correction even if this information had been lost, or was not provided with the scan.
In the next section of this work, we develop a new optimal method of slice timing correction (Filter-Shift) based on the fundamental properties of sampling theory in digital signal processing. By examining the properties of the signal of interest (The blood oxygen level depended signal: BOLD signal), we are able to design and implement an effective FIR filter to simultaneously remove noise and reconstruct the signal of interest at any shifted offset, without the need for sub-optimal interpolation.
In the final section, we investigate the effects of different motion types on the MR signal based on the Bloch equation, in order to develop a theoretical foundation from which we can create an optimal correction method. We devise a novel method to remove these artifacts: Discrete reconstruction of irregular fMRI trajectory (DRIFT). Our method calculates the exact displacement of the k-space samples due to motion at each dwell time and retrospectively corrects each slice of the fMRI volume using an inverse nonuniform Fourier transform. We conclude that a hybrid approach with both prospective and retrospective components are essentially required for optimal removal of motion artifacts from the fMRI data.
The combined work of this thesis provides two theoretically sound and extremely effective correction routines, that both remove artifacts and restore the underlying sampled signal. Motion correction and slice timing correction are typically the first two preprocessing steps to be applied to any fMRI data, and thus provide the foundation for any further analysis. While many other preprocessing steps can be omitted or included depending on the analysis, motion correction and slice timing correction are unequivocally beneficial and necessary for accurate and reliable results. This work provides a theoretical and quantitative framework that describes the optimal removal of artifacts associated with motion and slice timing
Prospective motion correction of 3D echo-planar imaging data for functional MRI using optical tracking.
We evaluated the performance of an optical camera based prospective motion correction (PMC) system in improving the quality of 3D echo-planar imaging functional MRI data. An optical camera and external marker were used to dynamically track the head movement of subjects during fMRI scanning. PMC was performed by using the motion information to dynamically update the sequence's RF excitation and gradient waveforms such that the field-of-view was realigned to match the subject's head movement. Task-free fMRI experiments on five healthy volunteers followed a 2×2×3 factorial design with the following factors: PMC on or off; 3.0mm or 1.5mm isotropic resolution; and no, slow, or fast head movements. Visual and motor fMRI experiments were additionally performed on one of the volunteers at 1.5mm resolution comparing PMC on vs PMC off for no and slow head movements. Metrics were developed to quantify the amount of motion as it occurred relative to k-space data acquisition. The motion quantification metric collapsed the very rich camera tracking data into one scalar value for each image volume that was strongly predictive of motion-induced artifacts. The PMC system did not introduce extraneous artifacts for the no motion conditions and improved the time series temporal signal-to-noise by 30% to 40% for all combinations of low/high resolution and slow/fast head movement relative to the standard acquisition with no prospective correction. The numbers of activated voxels (p<0.001, uncorrected) in both task-based experiments were comparable for the no motion cases and increased by 78% and 330%, respectively, for PMC on versus PMC off in the slow motion cases. The PMC system is a robust solution to decrease the motion sensitivity of multi-shot 3D EPI sequences and thereby overcome one of the main roadblocks to their widespread use in fMRI studies
Cortical depth dependent functional responses in humans at 7T: improved specificity with 3D GRASE
Ultra high fields (7T and above) allow functional imaging with high contrast-to-noise ratios and improved spatial resolution. This, along with improved hardware and imaging techniques, allow investigating columnar and laminar functional responses. Using gradient-echo (GE) (T2* weighted) based sequences, layer specific responses have been recorded from human (and animal) primary visual areas. However, their increased sensitivity to large surface veins potentially clouds detecting and interpreting layer specific responses. Conversely, spin-echo (SE) (T2 weighted) sequences are less sensitive to large veins and have been used to map cortical columns in humans. T2 weighted 3D GRASE with inner volume selection provides high isotropic resolution over extended volumes, overcoming some of the many technical limitations of conventional 2D SE-EPI, whereby making layer specific investigations feasible. Further, the demonstration of columnar level specificity with 3D GRASE, despite contributions from both stimulated echoes and conventional T2 contrast, has made it an attractive alternative over 2D SE-EPI. Here, we assess the spatial specificity of cortical depth dependent 3D GRASE functional responses in human V1 and hMT by comparing it to GE responses. In doing so we demonstrate that 3D GRASE is less sensitive to contributions from large veins in superficial layers, while showing increased specificity (functional tuning) throughout the cortex compared to GE
Cerebral correlates and statistical criteria of cross-modal face and voice integration
Perception of faces and voices plays a prominent role in human social interaction, making multisensory integration of cross-modal speech a topic of great interest in cognitive neuroscience. How to define po- tential sites of multisensory integration using functional magnetic resonance imaging (fMRI) is currently under debate, with three statistical criteria frequently used (e.g., super-additive, max and mean criteria). In the present fMRI study, 20 participants were scanned in a block design under three stimulus conditions: dynamic unimodal face, unimodal voice and bimodal face–voice. Using this single dataset, we examine all these statistical criteria in an attempt to define loci of face–voice integration. While the super-additive and mean criteria essentially revealed regions in which one of the unimodal responses was a deactivation, the max criterion appeared stringent and only highlighted the left hippocampus as a potential site of face– voice integration. Psychophysiological interaction analysis showed that connectivity between occipital and temporal cortices increased during bimodal compared to unimodal conditions. We concluded that, when investigating multisensory integration with fMRI, all these criteria should be used in conjunction with ma- nipulation of stimulus signal-to-noise ratio and/or cross-modal congruency
- …