3,162 research outputs found

    Novel characterization method of impedance cardiography signals using time-frequency distributions

    Get PDF
    The purpose of this document is to describe a methodology to select the most adequate time-frequency distribution (TFD) kernel for the characterization of impedance cardiography signals (ICG). The predominant ICG beat was extracted from a patient and was synthetized using time-frequency variant Fourier approximations. These synthetized signals were used to optimize several TFD kernels according to a performance maximization. The optimized kernels were tested for noise resistance on a clinical database. The resulting optimized TFD kernels are presented with their performance calculated using newly proposed methods. The procedure explained in this work showcases a new method to select an appropriate kernel for ICG signals and compares the performance of different time-frequency kernels found in the literature for the case of ICG signals. We conclude that, for ICG signals, the performance (P) of the spectrogram with either Hanning or Hamming windows (P¿=¿0.780) and the extended modified beta distribution (P¿=¿0.765) provided similar results, higher than the rest of analyzed kernels.Peer ReviewedPostprint (published version

    Compressive sensing based velocity estimation in video data

    Full text link
    This paper considers the use of compressive sensing based algorithms for velocity estimation of moving vehicles. The procedure is based on sparse reconstruction algorithms combined with time-frequency analysis applied to video data. This algorithm provides an accurate estimation of object's velocity even in the case of a very reduced number of available video frames. The influence of crucial parameters is analysed for different types of moving vehicles.Comment: 4 pages, 5 figure

    Performance evaluation of the Hilbert–Huang transform for respiratory sound analysis and its application to continuous adventitious sound characterization

    Get PDF
    © 2016. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/The use of the Hilbert–Huang transform in the analysis of biomedical signals has increased during the past few years, but its use for respiratory sound (RS) analysis is still limited. The technique includes two steps: empirical mode decomposition (EMD) and instantaneous frequency (IF) estimation. Although the mode mixing (MM) problem of EMD has been widely discussed, this technique continues to be used in many RS analysis algorithms. In this study, we analyzed the MM effect in RS signals recorded from 30 asthmatic patients, and studied the performance of ensemble EMD (EEMD) and noise-assisted multivariate EMD (NA-MEMD) as means for preventing this effect. We propose quantitative parameters for measuring the size, reduction of MM, and residual noise level of each method. These parameters showed that EEMD is a good solution for MM, thus outperforming NA-MEMD. After testing different IF estimators, we propose Kay¿s method to calculate an EEMD-Kay-based Hilbert spectrum that offers high energy concentrations and high time and high frequency resolutions. We also propose an algorithm for the automatic characterization of continuous adventitious sounds (CAS). The tests performed showed that the proposed EEMD-Kay-based Hilbert spectrum makes it possible to determine CAS more precisely than other conventional time-frequency techniques.Postprint (author's final draft

    Effect of sparsity-aware time–frequency analysis on dynamic hand gesture classification with radar micro-Doppler signatures

    Get PDF
    Dynamic hand gesture recognition is of great importance in human-computer interaction. In this study, the authors investigate the effect of sparsity-driven time-frequency analysis on hand gesture classification. The time-frequency spectrogram is first obtained by sparsity-driven time-frequency analysis. Then three empirical micro-Doppler features are extracted from the time-frequency spectrogram and a support vector machine is used to classify six kinds of dynamic hand gestures. The experimental results on measured data demonstrate that, compared to traditional time-frequency analysis techniques, sparsity-driven time-frequency analysis provides improved accuracy and robustness in dynamic hand gesture classification

    Time resolved tracking of a sound scatterer in a turbulent flow: non-stationary signal analysis and applications

    Get PDF
    It is known that ultrasound techniques yield non-intrusive measurements of hydrodynamic flows. For example, the study of the echoes produced by a large number of particle insonified by pulsed wavetrains has led to a now standard velocimetry technique. In this paper, we propose to extend the method to the continuous tracking of one single particle embedded in a complex flow. This gives a Lagrangian measurement of the fluid motion, which is of importance in mixing and turbulence studies. The method relies on the ability to resolve in time the Doppler shift of the sound scattered by the continuously insonfied particle. For this signal processing problem two classes of approaches are used: time-frequency analysis and parametric high resolution methods. In the first class we consider the spectrogram and reassigned spectrogram, and we apply it to detect the motion of a small bead settling in a fluid at rest. In more non-stationary turbulent flows where methods in the second class are more robust, we have adapted an Approximated Maximum Likelihood technique coupled with a generalized Kalman filter.Comment: 16 pages 9 figure
    • …
    corecore