3 research outputs found

    Improvements in the accuracy of an Inverse Problem Engine's output for the prediction of below-knee prosthetic socket interfacial loads

    No full text
    The monitoring of in-service loads on many components has become a routine operation for simple and well-understood cases in engineering. However, as the complexity of the structure increases so does the difficulty in obtaining an acceptable understanding of the real loading. It has been shown that it is possible to solve these problems by interfacing traditional analysis methodologies with more modern mathematical methods (i.e. artificial intelligence) in order to create a hybrid analysis tool. It has, however, been recognised that an Artificial Neural Network (ANN) predicts poorly in the high and low ranges of the envelope of which it is trying to predict. This paper presents results of research to develop the ANN Difference Method to improve the accuracy of the Inverse Problem Engine's output. This method has been applied to accurately predict the complex pressure distribution at the residual limb/socket interface of a lower-limb prosthesis. It has been shown that application of the ANN Difference Method to the output of a backpropagation neural network can reduce inherent errors that exist at the low and high ends of the ANN solution envelope. This powerful approach can offer load information at high speed once the relationship between the loading and response of the component has been established through training the ANN. Utilising an experimental technique combined with an ANN can provide in-service loads on complex components in real time as part of a sophisticated embedded system. © 2010 Elsevier Ltd. All rights reserved

    Lower limb prosthetic interfaces: Clinical and technological advancement and potential future direction

    Get PDF
    The human–prosthesis interface is one of the most complicated challenges facing the field of prosthetics, despite substantive investments in research and development by researchers and clinicians around the world. The journal of the International Society for Prosthetics and Orthotics, Prosthetics and Orthotics International, has contributed substantively to the growing body of knowledge on this topic. In celebrating the 50th anniversary of the International Society for Prosthetics and Orthotics, this narrative review aims to explore how human–prosthesis interfaces have changed over the last five decades; how research has contributed to an understanding of interface mechanics; how clinical practice has been informed as a result; and what might be potential future directions. Studies reporting on comparison, design, manufacturing and evaluation of lower limb prosthetic sockets, and osseointegration were considered. This review demonstrates that, over the last 50 years, clinical research has improved our understanding of socket designs and their effects; however, high-quality research is still needed. In particular, there have been advances in the development of volume and thermal control mechanisms with a few designs having the potential for clinical application. Similarly, advances in sensing technology, soft tissue quantification techniques, computing technology, and additive manufacturing are moving towards enabling automated, data-driven manufacturing of sockets. In people who are unable to use a prosthetic socket, osseointegration provides a functional solution not available 50 years ago. Furthermore, osseointegration has the potential to facilitate neuromuscular integration. Despite these advances, further improvement in mechanical features of implants, and infection control and prevention are needed.N/

    DEVELOPMENT OF A VIRTUAL TESTING LABORATORY FOR LOWER LIMB PROSTHESIS

    Get PDF
    The introduction of computer-aided tools into the product development process allows improving the quality of the product, evaluating different variants of the same product in a faster way and reducing time and costs. They can play a meaningful role also in designing custom-fit products (especially, those characterized by a tight interaction with the human body), increasing the comfort and improving people’s quality of life. This thesis concerns a specific custom-fit product, the lower limb prosthesis. It is part of a research project that aims at developing a new design platform centred on the digital model of the patient and his/her characteristics. The platform, named Prosthesis Virtual Laboratory (PVL), is being developed by the V&K Research Group (University of Bergamo) and integrates ICT tools and product-process knowledge. It provides two environments: one for prosthesis design (named Prosthesis Modelling Lab), both transfemoral and transtibial, and one for the prosthesis testing (named Virtual Testing Lab). The main objective has been to embed within the Virtual Testing Environment numerical simulation tools to analyse the interaction between the socket and the residual limb under different loading conditions, allowing the prosthetist to automatically run the simulation and optimize socket shape. Simulation tools, such as Finite Element Analysis (FEA), permit to predict the pressures at the interface socket-residual limb, evaluate the comfort of socket and validate the socket design before manufacturing phase. However, the diffusion of simulation tools in orthopaedic laboratories is strongly limited by the high level of competence required to use them. Furthermore, the implementation of the simulation model is time consuming and requires expensive resources, both humans and technological, especially onerous for small orthopaedic labs. To effectively employ the numerical analysis in prosthesis design, the simulation process has been automated and embedded within the virtual design platform. Therefore, in such a context, the specific scientific objectives have been to: • Critically analyse the state of the art with regard to methods and tools to evaluate socket-residual limb interaction. • Identify the key issues to automate the simulation activities. • Define a set of simulation rules and the Finite Element Analysis model. • Implement and integrate within the new design platform the automatic simulation procedure. • Test the integrated design platform with a case study. • Identify future development trends. Research activities have been organized into four main activities as follows. The first activity consisted in an extensive analysis of the last two decades State of the Art on numerical models adopted to study residual lower-limb and prosthetic socket interaction. Starting from literature, the key issues of the simulation process (e.g., geometric models reconstruction, materials characterization, simulation steps, and boundary conditions), the methodologies and procedures have been identified. Particular attention has been also paid to the parameters commonly adopted to evaluate socket comfort. This phase played a fundamental role since it constituted the basis for the implementation of the embedded simulation procedure. It also permitted to highlight that current finite element models are stand-alone and not integrated with prosthetic CAD or Digital Human Modelling (DHM) systems. In the second activity the tools and methods necessary to develop the embedded simulation module have been selected. By using these tools, it was possible to identify the simulation rules and the best practice procedures, which are fundamental to implement an automatic simulation module. Initially, the modelling tools have been considered since they provide the geometric models for the numerical analysis of the socket-residuum interaction and for the virtual gait analysis of the patient’s avatar. Then, particular attention has been paid on the choice of the FE solver, that has been made according to the results of preliminary FE models. They were implemented using two different solvers: Abaqus (commercial) and CalculiX (open-source). The latter has been experimented to verify the possibility to develop a design platform totally independent from commercial tools. However, according to the results, Abaqus has been chosen because it allows managing adequately simulation problems characterized by large deformations and difficult contact conditions, its results are comparable with those found in literature, and its scripting code does not require specific customization. The last considered tool was the Digital Human Modelling system (LifeMOD) since it permits to enhance the accuracy of the numerical analysis. By performing the gait simulation of the patient’s avatar, it provides the directions and the magnitude of forces and moments that act on the socket. The third activity consisted in defining the architecture of the simulation module, implementing the module and the interfaces with the socket CAD tool (namely Socket Modelling Assistant-SMA) to get the geometric models of the involved parts (socket and residual limb) and with the DHM system to acquire forces acting on the socket during patient’s walking. The simulation module has been implemented using the Python language and the integrated environment works as follows. Once the prosthetist has created the 3D socket model, SMA acquires the input for the analysis (e.g., residual limb length, patient’s weight, friction coefficient, material properties), and produces the files required to generate the FE model. Abaqus automatically generates the FE model without any human intervention, solves the analysis and generates the output file containing the pressure values. Results are imported in SMA and visualized with a colour map. SMA evaluates pressure distribution and highlights the areas that should be modified. Geometry modifications are needed in the areas where pressure exceeds the maximum value and are carried out automatically by the system or by the prosthetist using the virtual tools available in SMA. Then, the system re-executes the simulation. Through this iterative process of adjustments, the socket shape is modified and optimized in order to eliminate undercuts, minimize weight and, especially, distribute loads in the appropriate way so that they can be tolerated for the longest period of time. The fourth and last activity concerned the test and validation of the simulation module integrated within the new design platform, by considering a transfemoral patient. The new virtual process and the key issues of the simulation procedure have been tested starting from the patient’s data acquisition to the release of the socket using also data coming from the gait simulation with the DHM system. The geometric model of the residual limb has been reconstructed from MRI images and the socket has been modelled using SMA. Through an iterative process, the socket shape has been optimized until the pressure distribution on the residuum was consistent. Preliminary activity concerning the FE model validation has been performed comparing the pressure distribution experimentally acquired with pressure transducers over the residuum with the simulation results. To accomplish this task, the geometric model of the real socket has been acquired using reverse engineering techniques. Two numerical simulations have been implemented, they differ for the residuum geometric models adopted: from MRI and from 3D scanning. Preliminary results have been considered positive but improvements are necessary. As an example, some geometric inconsistencies, occurred during the acquisition of the geometric model of the residual limb, have reduced the accuracy of the final results. To complete the evaluation of the simulation model, a new residuum geometric model is needed and a refinement of the material model characterization is desirable. To conclude, the simulation module embedded within Virtual Testing Laboratory has improved the prosthesis development process with the goal of assessing and validating the socket shape under different load conditions (static or dynamic) before the manufacturing phase. The testing phase of the new procedure has demonstrated the feasibility of the virtual approach for lower limb prosthesis design. The tests carried out permitted to highlight necessary improvements and future developments, such as the definition of a protocol to acquire the residual limb through MRI and 3D scan, refinement of the FE model (e.g., non-linear viscoelastic behaviour for soft tissues, friction coefficients), parallel computing to improve simulation performances, open-source solvers to implement a design platform totally independent from commercial systems, and a massive test campaign involving transtibial and transfemoral patients to fully validate the FE model and the design platform
    corecore