38,596 research outputs found

    The grid-dose-spreading algorithm for dose distribution calculation in heavy charged particle radiotherapy

    Get PDF
    A new variant of the pencil-beam (PB) algorithm for dose distribution calculation for radiotherapy with protons and heavier ions, the grid-dose spreading (GDS) algorithm, is proposed. The GDS algorithm is intrinsically faster than conventional PB algorithms due to approximations in convolution integral, where physical calculations are decoupled from simple grid-to-grid energy transfer. It was effortlessly implemented to a carbon-ion radiotherapy treatment planning system to enable realistic beam blurring in the field, which was absent with the broad-beam (BB) algorithm. For a typical prostate treatment, the slowing factor of the GDS algorithm relative to the BB algorithm was 1.4, which is a great improvement over the conventional PB algorithms with a typical slowing factor of several tens. The GDS algorithm is mathematically equivalent to the PB algorithm for horizontal and vertical coplanar beams commonly used in carbon-ion radiotherapy while dose deformation within the size of the pristine spread occurs for angled beams, which was within 3 mm for a single proton pencil beam of 3030^\circ incidence, and needs to be assessed against the clinical requirements and tolerances in practical situations.Comment: 7 pages, 3 figure

    Development and operation of a pixel segmented liquid-filled linear array for radiotherapy quality assurance

    Full text link
    A liquid isooctane (C8_{8}H18_{18}) filled ionization linear array for radiotherapy quality assurance has been designed, built and tested. The detector consists of 128 pixels, each of them with an area of 1.7 mm ×\times 1.7 mm and a gap of 0.5 mm. The small pixel size makes the detector ideal for high gradient beam profiles like those present in Intensity Modulated Radiation Therapy (IMRT) and radiosurgery. As read-out electronics we use the X-Ray Data Acquisition System (XDAS) with the Xchip developed by the CCLRC. Studies concerning the collection efficiency dependence on the polarization voltage and on the dose rate have been made in order to optimize the device operation. In the first tests we have studied dose rate and energy dependences, and signal reproducibility. Dose rate dependence was found lower than 2.5 % up to 5 Gy min1^{-1}, and energy dependence lower than 2.1 % up to 20 cm depth in solid water. Output factors and penumbras for several rectangular fields have been measured with the linear array and were compared with the results obtained with a 0.125 cm3^{3} air ionization chamber and radiographic film, respectively. Finally, we have acquired profiles for an IMRT field and for a virtual wedge. These profiles have also been compared with radiographic film measurements. All the comparisons show a good correspondence. Signal reproducibility was within a 2% during the test period (around three months). The device has proved its capability to verify on-line therapy beams with good spatial resolution and signal to noise ratio.Comment: 16 pages, 12 figures Submitted to Phys. Med. Bio

    Towards Laser Driven Hadron Cancer Radiotherapy: A Review of Progress

    Get PDF
    It has been known for about sixty years that proton and heavy ion therapy is a very powerful radiation procedure for treating tumours. It has an innate ability to irradiate tumours with greater doses and spatial selectivity compared with electron and photon therapy and hence is a tissue sparing procedure. For more than twenty years powerful lasers have generated high energy beams of protons and heavy ions and hence it has been frequently speculated that lasers could be used as an alternative to RF accelerators to produce the particle beams necessary for cancer therapy. The present paper reviews the progress made towards laser driven hadron cancer therapy and what has still to be accomplished to realise its inherent enormous potential.Comment: 40 pages, 24 figure

    Local treatment failure after globe-conserving therapy for choroidal melanoma.

    Get PDF
    Local treatment failure after globe-conserving therapy for choroidal melanoma is a surgical complication with significant morbidity to the vision and eye. Few reports in the literature have addressed this complication exclusively. A review of the published literature with reference to local treatment failure in the management of choroidal melanoma was performed to make known the potential differences in failure rates between treatment modalities and methods. A search of the literature regarding local treatment failure was performed to identify relevant studies using combinations of the following keywords on PubMed: uveal melanoma, choroidal melanoma, local recurrence, local failure, endoresection, gamma knife, radiotherapy, helium, iodine, proton, palladium, ruthenium, trans-scleral resection, transpupillary thermotherapy. Further studies were found by searching the text and references of previously identified studies for articles reporting local treatment failure rates in choroidal melanoma. Among the 49 studies identified, the local treatment failure rate ranged from 0% to 55.6%, with follow-up ranging from 10 to 150 months. The two most widely used forms of radiation therapy, iodine-125 and ruthenium-106 brachytherapy, were both associated with a local recurrence rate of 9.6%. The weighted-average of treatment failure in all radiation therapies was 6.15% compared with 18.6% in surgical and 20.8% in laser therapies. Rates of local treatment failure for globe-conserving therapy of choroidal melanoma varied widely between modalities and between centres using similar modalities. Radiation therapy overall resulted in lower local treatment failures compared with surgical or transpupillary thermotherapy

    The detection of patients at risk of gastrointestinal toxicity during pelvic radiotherapy by electronic nose and FAIMS : a pilot study

    Get PDF
    It is well known that the electronic nose can be used to identify differences between human health and disease for a range of disorders. We present a pilot study to investigate if the electronic nose and a newer technology, FAIMS (Field Asymmetric Ion Mobility Spectrometry), can be used to identify and help inform the treatment pathway for patients receiving pelvic radiotherapy, which frequently causes gastrointestinal side-effects, severe in some. From a larger group, 23 radiotherapy patients were selected where half had the highest levels of toxicity and the others the lowest. Stool samples were obtained before and four weeks after radiotherapy and the volatiles and gases emitted analysed by both methods; these chemicals are products of fermentation caused by gut microflora. Principal component analysis of the electronic nose data and wavelet transform followed by Fisher discriminant analysis of FAIMS data indicated that it was possible to separate patients after treatment by their toxicity levels. More interestingly, differences were also identified in their pre-treatment samples. We believe these patterns arise from differences in gut microflora where some combinations of bacteria result to give this olfactory signature. In the future our approach may result in a technique that will help identify patients at “high risk” even before radiation treatment is started
    corecore