1,527,876 research outputs found
High-Resolution Spectroscopic Study of Extremely Metal-Poor Star Candidates from the SkyMapper Survey
The SkyMapper Southern Sky Survey is carrying out a search for the most
metal-poor stars in the Galaxy. It identifies candidates by way of its unique
filter set that allows for estimation of stellar atmospheric parameters. The
set includes a narrow filter centered on the Ca II K 3933A line, enabling a
robust estimate of stellar metallicity. Promising candidates are then confirmed
with spectroscopy. We present the analysis of Magellan-MIKE high-resolution
spectroscopy of 122 metal-poor stars found by SkyMapper in the first two years
of commissioning observations. 41 stars have [Fe/H] <= -3.0. Nine have [Fe/H]
<= -3.5, with three at [Fe/H] ~ -4. A 1D LTE abundance analysis of the elements
Li, C, Na, Mg, Al, Si, Ca, Sc, Ti, Cr, Mn, Co, Ni, Zn, Sr, Ba and Eu shows
these stars have [X/Fe] ratios typical of other halo stars. One star with low
[X/Fe]
[X/Fe values appears to be "Fe-enhanced," while another star has an extremely
large [Sr/Ba] ratio: >2. Only one other star is known to have a comparable
value. Seven stars are "CEMP-no" stars ([C/Fe] > 0.7, [Ba/Fe] < 0). 21 stars
exhibit mild r-process element enhancements (0.3 <=[Eu/Fe] < 1.0), while four
stars have [Eu/Fe] >= 1.0. These results demonstrate the ability to identify
extremely metal-poor stars from SkyMapper photometry, pointing to increased
sample sizes and a better characterization of the metal-poor tail of the halo
metallicity distribution function in the future.Comment: Minor corrections to text, missing data added to Tables 3 and 4;
updated to match published version. Complete tables included in sourc
High-resolution electrochemical STM of redox metalloproteins
Electrochemical studies of redox active metalloproteins have become an increasingly fruitful area of study in recent years, particularly with the single-molecule resolution capability of electrochemical scanning tunnelling microscopy (EC-STM) which provides both imaging and current-voltage spectroscopy under bipotentiostatic control. In this review, some of the most exciting advances in recent years are outlined, and directions for future research are considered
High-resolution x-ray telescopes
High-energy astrophysics is a relatively young scientific field, made
possible by space-borne telescopes. During the half-century history of x-ray
astronomy, the sensitivity of focusing x-ray telescopes-through finer angular
resolution and increased effective area-has improved by a factor of a 100
million. This technological advance has enabled numerous exciting discoveries
and increasingly detailed study of the high-energy universe-including accreting
(stellar-mass and super-massive) black holes, accreting and isolated neutron
stars, pulsar-wind nebulae, shocked plasma in supernova remnants, and hot
thermal plasma in clusters of galaxies. As the largest structures in the
universe, galaxy clusters constitute a unique laboratory for measuring the
gravitational effects of dark matter and of dark energy. Here, we review the
history of high-resolution x-ray telescopes and highlight some of the
scientific results enabled by these telescopes. Next, we describe the planned
next-generation x-ray-astronomy facility-the International X-ray Observatory
(IXO). We conclude with an overview of a concept for the next next-generation
facility-Generation X. The scientific objectives of such a mission will require
very large areas (about 10000 m2) of highly-nested lightweight
grazing-incidence mirrors with exceptional (about 0.1-arcsecond) angular
resolution. Achieving this angular resolution with lightweight mirrors will
likely require on-orbit adjustment of alignment and figure.Comment: 19 pages, 11 figures, SPIE Conference 7803 "Adaptive X-ray Optics",
part of SPIE Optics+Photonics 2010, San Diego CA, 2010 August 2-
High resolution stopwatch for cents
A very low-cost, easy-to-make stopwatch is presented to support various
experiments in mechanics. The high-resolution stopwatch is based on two
photodetectors connected directly to the microphone input of the sound card. A
dedicated free open-source software has been developed and made available to
download. The efficiency is demonstrated by a free fall experiment
Towards high-resolution astronomical imaging
This paper is a report from a recent meeting on "the Future of
high-resolution imaging in the visible and infrared", reviewing the
astronomical drivers for development and the technological advances that might
boost performance. Each of the authors listed contributed a section themselves.Comment: 6 pages, 7 figures, 11 contributors, Accepted for publication in
Astronomy & Geophysics of the RAS, June 2019 issu
High-Resolution Spectroscopy of FUors
High-resolution spectroscopy was obtained of the FUors FU Ori and V1057 Cyg
between 1995 and 2002 with SOFIN at NOT and with HIRES at Keck I. During those
years FU Ori remained about 1 mag. (in B) below its 1938-39 maximum brightness,
but V1057 Cyg (B ~ 10.5 at peak in 1970-71) faded from about 13.5 to 14.9 and
then recovered slightly. Their photospheric spectra resemble a rotating G0 Ib
supergiant, with v_eq sin i = 70 km/s for FU Ori and 55 km/s for V1057 Cyg. As
V1057 Cyg faded, P Cyg structure in Halpha and the IR CaII lines strengthened
and a complex shortward-displaced shell spectrum increased in strength,
disappeared in 1999, and reappeared in 2001. Night-to-night changes in the wind
structure of FU Ori show evidence of sporadic infall. The strength of P Cyg
absorption varied cyclically with a period of 14.8 days, with phase stability
maintained over 3 seasons, and is believed to be the rotation period. The
structure of the photospheric lines also varies cyclically, but with a period
of 3.54 days. A similar variation may be present in V1057 Cyg. As V1057 Cyg has
faded, the emission lines of a pre-existing low-excitation chromosphere have
emerged, so we believe the `line doubling' in V1057 Cyg is produced by these
central emission cores in the absorption lines, not by orbital motion in an
inclined Keplerian disk. No dependence of v_eq sin i on wavelength or
excitation potential was detected in either star, again contrary to expectation
for a self-luminous accretion disk. Nor are critical lines in the near infrared
accounted for by synthetic disk spectra. A rapidly rotating star near the edge
of stability (Larson 1980), can better explain these observations. FUor
eruptions may not be a property of ordinary TTS, but may be confined to a
special subspecies of rapid rotators having powerful quasi-permanent winds.Comment: 41 pages (including 32 figures and 9 tables); ApJ, in press; author
affiliation, figs. 3 and 9 correcte
Single-cell transcriptomics : a high-resolution avenue for plant functional genomics
Plant function is the result of the concerted action of single cells in different tissues. Advances in RNA-seq technologies and tissue processing allow us now to capture transcriptional changes at single-cell resolution. The incredible potential of single-cell RNA-seq lies in the novel ability to study and exploit regulatory processes in complex tissues based on the behaviour of single cells. Importantly, the independence from reporter lines allows the analysis of any given tissue in any plant. While there are challenges associated with the handling and analysis of complex datasets, the opportunities are unique to generate knowledge of tissue functions in unprecedented detail and to facilitate the application of such information by mapping cellular functions and interactions in a plant cell atlas. [Abstract copyright: Copyright © 2019 The Authors. Published by Elsevier Ltd.. All rights reserved.
High resolution angular sensor
Specifications for the pointing stabilization system of the large space telescope were used in an investigation of the feasibility of reducing ring laser gyro output quantization to the sub-arc-second level by the use of phase locked loops and associated electronics. Systems analysis procedures are discussed and a multioscillator laser gyro model is presented along with data on the oscillator noise. It is shown that a second order closed loop can meet the measurement noise requirements when the loop gain and time constant of the loop filter are appropriately chosen. The preliminary electrical design is discussed from the standpoint of circuit tradeoff considerations. Analog, digital, and hybrid designs are given and their applicability to the high resolution sensor is examined. the electrical design choice of a system configuration is detailed. The design and operation of the various modules is considered and system block diagrams are included. Phase 1 and 2 test results using the multioscillator laser gyro are included
- …
