27 research outputs found

    Load Frequency Control (LFC) Strategies in Renewable Energy‐Based Hybrid Power Systems:A Review

    Get PDF
    The hybrid power system is a combination of renewable energy power plants and conventional energy power plants. This integration causes power quality issues including poor settling times and higher transient contents. The main issue of such interconnection is the frequency variations caused in the hybrid power system. Load Frequency Controller (LFC) design ensures the reliable and efficient operation of the power system. The main function of LFC is to maintain the system frequency within safe limits, hence keeping power at a specific range. An LFC should be supported with modern and intelligent control structures for providing the adequate power to the system. This paper presents a comprehensive review of several LFC structures in a diverse configuration of a power system. First of all, an overview of a renewable energy-based power system is provided with a need for the development of LFC. The basic operation was studied in single-area, multi-area and multi-stage power system configurations. Types of controllers developed on different techniques studied with an overview of different control techniques were utilized. The comparative analysis of various controllers and strategies was performed graphically. The future scope of work provided lists the potential areas for conducting further research. Finally, the paper concludes by emphasizing the need for better LFC design in complex power system environments

    Optimal fuzzy-PID controller with derivative filter for load frequency control including UPFC and SMES

    Get PDF
    A newly adopted optimization technique known as sine-cosine algorithm (SCA) is suggested in this research article to tune the gains of Fuzzy-PID controller along with a derivative filter (Fuzzy-PIDF) of a hybrid interconnected system for the Load Frequency Control (LFC). The scrutinized multi-generation system considers hydro, gas and thermal sources in all areas of the dual area power system integrated with UPFC (unified power flow controller) and SMES (Super-conducting magnetic energy storage) units. The preeminence of the offered Fuzzy-PIDF controller is recognized over Fuzzy-PID controller by comparing their dynamic performance indices concerning minimum undershoot, settling time and also peak overshoot. Finally, the sensitiveness and sturdiness of the recommended control method are proved by altering the parameters of the system from their nominal values and by the implementation of random loading in the system

    Small-signal stability analysis of hybrid power system with quasi-oppositional sine cosine algorithm optimized fractional order PID controller

    Get PDF
    This article deals with the frequency instability problem of a hybrid energy power system (HEPS) coordinated with reheat thermal power plant. A stochastic optimization method called a sine-cosine algorithm (SCA) is, initially, applied for optimum tuning of fractional-order proportional-integral-derivative (FOPI-D) controller gains to balance the power generation and load profile. To accelerate the convergence mobility and escape the solutions from the local optimal level, quasi-oppositional based learning (Q-OBL) is integrated with SCA, which results in QOSCA. In this work, the PID-controller's derivative term is placed in the feedback path to avoid the set-point kick problem. A comparative assessment of the energy-storing devices is shown for analyzing the performances of the same in HEPS. The qualitative and quantitative evaluation of the results shows the best performance with the proposed QOSCA: FOPI-D controller compared to SCA-, grey wolf optimizer (GWO), and hyper-spherical search (HSS) optimized FOPI-D controller. It is also seen from the results that the proposed QOSCA: FOPI-D controller has satisfactory disturbance rejection ability and shows robust performance against parametric uncertainties and random load perturbation. The efficacy of the designed controller is confirmed by considering generation rate constraint, governor dead-band, and boiler dynamics effects

    Optimal tuning of proportional integral controller for fixed-speed wind turbine using grey wolf optimizer

    Get PDF
    The need for tuning the PI controller is to improve its performance metrics such as rise time, settling time and overshoot. This paper proposed the Grey Wolf Optimizer (GWO) tuning method of a Proportional Integral (PI) controller for fixed speed Wind Turbine. The objective is to overcome the limitations in using the PSO and GA tuning methods for tuning the PI controller, such as quick convergence occurring too soon into a local optimum, and the controller step input response. The GWO, the Particle Swarm Optimization (PSO), and the Genetic Algorithm (GA) tuning methods were implemented in the Matlab 2016b to search the optimal gains of the Proportional and Integral controller through minimization of the objective function. A comparison was made between the results obtained from the GWO tuning method against PSO and GA tuning techniques. The GWO computed the smallest value of the objective function minimized. It exhibited faster convergence and better time response specification compared to other methods. These and more performance indicators show the superiority of the GWO tuning method

    Frequency deviations stabilizations in restructured power systems using coordinative controllers

    Get PDF
    Modern restructured power system faces excessive frequency aberrations due to the intermittent renewable generations and persistently changing load demands. An efficient and robust control strategy is obligatory to minimise deviations in the system frequency and tie-line to avoid any possible blackout. Hence, in this research, to achieve this target, automatic generation control (AGC) is utilized as a secondary controller to alleviate the changes in interconnected restructured systems at uncertainties. The objective of AGC is to quickly stabilize the deviations in frequency and tie-line power following load fluctuations. This thesis addresses the performance of AGC in two-area restructured power systems with many sophisticated control strategies in the presence of renewable and traditional power plants. As per literature of research work, there are quite a few research studies on AGC of a restructured system using optimized coordinative controllers. Besides, investigations on advanced optimized-based coordinative controller approaches are also rare to find in the literature. So, various combinations of two degrees of freedom (2DOF) controllers are utilized as supplementary controllers to diminish the frequency deviations. Nevertheless, the interconnected tie-lines are typically congested in areas with huge penetration of renewable sources, which may reduce the tie -line capability. Therefore, distinct FACTS controllers and ultra-capacitor (UC) are integrated into two-area restructured systems for strengthening the tie-line power and frequency. Further, new optimization techniques such as cuckoo search (CS), bat algorithm (BA), moth-flame optimization (MFO) are utilized in this work for investigating the suggested 2DOF controllers and compared their performance in all contracts of restructured systems. As per the simulation outcomes, the amalgamation of DPFC and UC with MFObased 2DOF PID-FOPDN shows low fluctuation rate in frequency and tie-line power. Besides, the settling times (ST) of two areas are 9.5 S for ΔF1, 8.2 S for ΔF2, and 10.15 S for ΔPtie. The robustness of the suggested controller has been verified by ±25% variations in system parameters and loading conditions

    Selfish Herd Optimisation based fractional order cascaded controllers for AGC study

    Get PDF
    In a modern, and complex power system (PS), robust controller is obligatory to regulate the frequency under uncertain load/parameter change of the system. In addition to this, presence of nonlinearities, load frequency control (LFC) of a Power System becomes more challenging which necessitates a suitable, and robust controller. Single stage controller does not perform immensely against aforesaid changed conditions. So, a novel non-integer/fractional order (FO) based two-stage controller incorporated with 2-degrees of freedom (2-DOF), derivative filter (N), named as 2-DOF-FOPIDN-FOPDN controller, is adopted to improve the dynamic performance of a 3-area power system. Each area of the power system consists of both non-renewable and renewable generating units. Again, to support the superior performance of 2-DOF-FOPIDN-FOPDN controller, it is compared with the result produced by PID, FOPID, and 2-DOF-PIDN-PDN controllers. The optimal design of these controllers is done by applying Selfish Herd Optimisation (SHO) technique. Further, the robustness of the 2-DOF-FOPIDN-FOPDN controller is authenticated by evaluating the system performance under parameter variation. The work is further extended to prove the supremacy of SHO algorithm over a recently published article based on pathfinder algorithm (PFA)

    Novel PID Controller on Battery Energy Storage Systems for Frequency Dynamics Enhancement

    Get PDF
    Frequency dynamics is one of the important aspects of power system stability. From the frequency dynamics, the operator could plan how is the reliability of the electricity. The frequency can be maintained by controlling the balance between load demand and generation. To maintain the balance of the generation, the governor is playing an important role to increase the speed of the turbine and enhance the generating capacity of the generator (ramp-up). However, as the speed of the governor is slower than the increasing load demand, in the sub-transient area, the frequency may experience higher overshoot. Hence, it is important to add additional devices such as battery energy storage systems to enhance the frequency dynamics response in the sub-transient area. One of the important parts of storage is the controller. The controller must make sure the storage charges and discharge energy are in the sub-transient area. Hence PID controller can be the solution to make the storage operate optimally This paper proposed a novel PID controller on battery energy storage systems (BESS) to enhance the dynamics performance of frequencies. The five-area power system is used as the test system to investigate the efficacy of the proposed novel idea. Time domain simulation is investigated to see the improvement of the frequency dynamics response. From the simulation results, it is found that adding a PID controller on BESS could enhance the BESS response and result in frequency dynamics response improvement

    Data-Intensive Computing in Smart Microgrids

    Get PDF
    Microgrids have recently emerged as the building block of a smart grid, combining distributed renewable energy sources, energy storage devices, and load management in order to improve power system reliability, enhance sustainable development, and reduce carbon emissions. At the same time, rapid advancements in sensor and metering technologies, wireless and network communication, as well as cloud and fog computing are leading to the collection and accumulation of large amounts of data (e.g., device status data, energy generation data, consumption data). The application of big data analysis techniques (e.g., forecasting, classification, clustering) on such data can optimize the power generation and operation in real time by accurately predicting electricity demands, discovering electricity consumption patterns, and developing dynamic pricing mechanisms. An efficient and intelligent analysis of the data will enable smart microgrids to detect and recover from failures quickly, respond to electricity demand swiftly, supply more reliable and economical energy, and enable customers to have more control over their energy use. Overall, data-intensive analytics can provide effective and efficient decision support for all of the producers, operators, customers, and regulators in smart microgrids, in order to achieve holistic smart energy management, including energy generation, transmission, distribution, and demand-side management. This book contains an assortment of relevant novel research contributions that provide real-world applications of data-intensive analytics in smart grids and contribute to the dissemination of new ideas in this area

    Frequency stabilization in interconnected power system using bat and harmony search algorithm with coordinated controllers

    Get PDF
    Modern power system faces excessive frequency aberrations due to the intermittent renewable generations and persistently changing load demands. To avoid any possible blackout, an efficient and robust control strategy is obligatory to minimize deviations in the system frequency and tieline. Hence, to achieve this target, a new two-degree of freedom-tilted integral derivative with filter (2DOF–TIDN) controller is proposed in this work for a two-area wind-hydro-diesel power system. To enhance the outcome of the proposed 2DOF–TIDN controller, its gain parameters are optimized with the use of a newly designed hybrid bat algorithm-harmony search algorithm (hybrid BA–HSA) technique. The effectiveness and superiority of hybrid BA–HSA tuned 2DOF–TIDN is validated over various existing optimization techniques like cuckoo search (CS), particle swarm optimization (PSO),HSA, BA and teaching learning-based optimization (TLBO). To further refine the system outcome in the dynamic conditions, several flexible AC transmission systems (FACTS) and superconducting magnetic energy storage (SMES) units are adopted for enriching the frequency and tie-line responses. The FACTS controllers like static synchronous series compensator (SSSC), thyristor-controlled phase shifter (TCPS), unified power flow controller (UPFC) and interline power flow controller (IPFC) are employed with SMES simultaneously. The simulation results disclose that the hybrid BA–HSA based 2DOF–TIDN shows superior dynamic performance with IPFC–SMES than other studied approaches. A sensitivity analysis is examined to verify the robustness of proposed controller under ±25% changes in loading and system parameters