14,899 research outputs found

    Bedroom indoor air comfort : a critical analysis

    Get PDF
    The criteria that are currently used for the assessment of Indoor Air Quality in a residential context were developed in the ‘80s and relate to comfort during occupancy. More than half the time at home however, is spent in the bedroom. There is no strong indication that the criteria that are traditionally used to assess Indoor Air Quality also relate to the level of comfort while asleep. Moreover, analysis of the results of a performance assessment of frequently used residential ventilation systems based on these traditional criteria, shows that they are dominated by the pollution level in the bedrooms

    RRx-001 in Refractory Small-Cell Lung Carcinoma: A Case Report of a Partial Response after a Third Reintroduction of Platinum Doublets.

    Get PDF
    RRx-001 is a pan-active, systemically nontoxic epigenetic inhibitor under investigation in advanced non-small cell lung cancer, small-cell lung cancer and high-grade neuroendocrine tumors in a Phase II clinical trial entitled TRIPLE THREAT (NCT02489903), which reexposes patients to previously effective but refractory platinum doublets after treatment with RRx-001. The purpose of this case study is first to report a partial response to carboplatin and etoposide in a patient with small-cell lung cancer pretreated with RRx-001, indicating episensitization or resensitization by epigenetic mechanisms, and second to discuss the literature related to small-cell lung cancer and episensitization

    Experimental investigation on thermal comfort model between local thermal sensation and overall thermal sensation

    Get PDF
    To study the human local and overall thermal sensations, a series of experiments under various conditions were carried out in a climate control chamber. The adopted analysis method considered the effect of the weight coefficient of local average skin temperature and density of the cold receptors’ distribution in different local body areas. The results demonstrated that the thermal sensation of head, chest, back and hands is warmer than overall thermal sensation. The mean thermal sensation votes of those local areas were more densely distributed. In addition, the thermal sensation of arms, tight and calf was colder than the overall thermal sensation, which pronounced that thermal sensation votes were more dispersed. The thermal sensation of chest and back had a strong linear correlation with overall thermal sensation. Considering the actual scope of air-conditioning regulation, the human body was classified into three local parts: a) head, b) upper part of body and c) lower part of body. The prediction model of both the three-part thermal sensation and overall thermal sensation was developed. Weight coefficients were 0.21, 0.60 and 0.19 respectively. The model provides scientist basis for guiding the sage installation place of the personal ventilation system to achieve efficient energy use

    Thermal comfort in residential buildings with water based heating systems: a tool for selecting appropriate heat emitters when using µ-cogeneration

    Get PDF
    As a consequence of people becoming more aware of their impact on the environment, there is an increasing demand for low energy buildings. Forced by regulation, building envelopes are improving and heating and cooling systems with higher efficiencies are being installed. The public are willing to embrace these new technologies, as long as they do not affect the quality of their indoor environment. In this paper, an introduction to research on the realisation of the indoor thermal comfort in residential buildings with water based, low-energy heating systems is given. The basis for this work is a more realistic definition of comfort temperatures for residential buildings. Subsequently, appropriate heat emitters to realise that thermal comfort in an efficient way are identified, taking into account the limitations of the production system under consideration. An example of a µ-cogeneration system is presented as a case study

    Thermal Perception in Mild Climate: Adaptive Thermal Models for Schools

    Get PDF
    A comprehensive assessment of indoor environmental conditions is performed on a representative sample of classrooms in schools across southern Spain (Mediterranean climate) to evaluate the thermal comfort level, thermal perception and preference, and the relationship with HVAC systems, with a comparison of seasons and personal clothing. Almost fifty classrooms were studied and around one thousand pool-surveys distributed among their occupants, aged 12 to 17. These measurements were performed during spring, autumn, and winter, considered the most representative periods of use for schools. A new proposed protocol has been developed for the collection and subsequent analysis of data, applying thermal comfort indicators and using the most frequent predictive models, rational (RTC) and adaptive (ATC), for comparison. Cooling is not provided in any of the rooms and natural ventilation is found in most of the spaces during midseasons. Despite the existence of a general heating service in almost all classrooms in the cold period, the use of mechanical ventilation is limited. Heating did not usually provide standard set-point temperatures. However, this did not lead to widespread complaints, as occupants perceive the thermal environment as neutral—varying greatly between users—and show a preference for slightly colder environments. Comparison of these thermal comfort votes and the thermal comfort indicators used showed a better fit of thermal preference over thermal sensation and more reliable results when using regional ATC indicators than the ASHRAE adaptive model. This highlights the significance of inhabitants’ actual thermal perception. These findings provide useful insight for a more accurate design of this type of building, as well as a suitable tool for the improvement of existing spaces, improving the conditions for both comfort and wellbeing in these spaces, as well as providing a better fit of energy use for actual comfort conditions

    Design and implementation of cloud enabled random neural network-based decentralized smart controller with intelligent sensor nodes for HVAC

    Get PDF
    Building energy management systems (BEMSs) monitor and control the heating ventilation and air conditioning (HVAC) of buildings in addition to many other building systems and utilities. Wireless sensor networks (WSNs) have become the integral part of BEMS at the initial implementation phase or latter when retro fitting is required to upgrade older buildings. WSN enabled BEMS, however, have several challenges which are managing data, controllers, actuators, intelligence, and power usage of wireless components (which might be battery powered). The wireless sensor nodes have limited processing power and memory for embedding intelligence in the sensor nodes. In this paper, we present a random neural network (RNN)-based smart controller on a Internet of Things (IoT) platform integrated with cloud processing for training the RNN which has been implemented and tested in an environment chamber. The IoT platform is modular and not limited to but has several sensors for measuring temperature, humidity, inlet air coming from the HVAC duct and PIR. The smart RNN controller has three main components: 1) base station; 2) sensor nodes; and 3) the cloud with embedded intelligence on each component for different tasks. This IoT platform is integrated with cloud processing for training the RNN. The RNN-based occupancy estimator is embedded in sensor node which estimates the number of occupants inside the room and sends this information to the base station. The base station is embedded with RNN models to control the HVAC on the basis of setpoints for heating and cooling. The HVAC of the environment chamber consumes 27.12% less energy with smart controller as compared to simple rule-based controllers. The occupancy estimation time is reduced by our proposed hybrid algorithm for occupancy estimation that combines RNN-based occupancy estimator with door sensor node (equipped with PIR and magnetic reed switch). The results show that accuracy of hybrid RNN occupancy estimator is 88%

    Evaluation of thermal comfort conditions in a classroom equipped with radiant cooling systems and subjected to uniform convective environment

    Get PDF
    The aim of this work is to evaluate numerically the human thermal response that 24 students and 1 teacher feel in a classroom equipped with radiant cooling systems and subjected to uniform convective environments, in lightly warm conditions. The evolution of thermal comfort conditions, using the PMV index, is made by the multi-nodal human thermal comfort model. In this numerical model, that works in transient or steady-state conditions and simulates simultaneously a group of persons, the three-dimensional body is divided in 24 cylindrical and 1 spherical elements. Each element is divided in four parts (core, muscle, fat and skin), sub-divided in several layers, and protected by several clothing layers. This numerical model is divided in six parts: human body thermal system, clothing thermal system, integral equations resolution system, thermoregulatory system, heat exchange between the body and the environment and thermal comfort evaluation. Seven different radiant systems are combined to three convective environments. In the radiant systems (1) no radiant system without warmed curtain, (2) no radiant system with warmed curtain, (3) radiant floors cooling system with warmed curtain, (4) radiant panels cooling system with warmed curtain, (5) radiant ceiling cooling system with warmed curtain, (6) radiant floor and panels cooling system with warmed curtain and (7) radiant ceiling and panels cooling system with warmed curtain are analysed, while in the convective environments (1) without air velocity field and with uniform air velocity field of (2) 0.2 m/s and (3) 0.6 m/s are also analysed. The internal air temperature and internal surfaces temperature are 28 degrees C, the radiant cooling surfaces temperature are 19 degrees C and the warmed internal curtains surfaces temperatures, subjected to direct solar radiation, are 40 degrees C. The numerical model calculates the Mean Radiant Temperature field, the human bodies' temperatures field and the thermal comfort level, for the 25 occupants, for the 21 analysed situations. Without uniform air velocity field, when only one individual radiant cooling system is used, the Predicted Percentage of Dissatisfied people is lowest when the radiant floor cooling system is applied and is highest when the radiant panel cooling system is applied. When are combined the radiant ceiling or the floor cooling systems with the radiant panel cooling system the Predicted Percentage of Dissatisfied people decreases. When the uniform air velocity increases the thermal comfort level, that the occupants are subjected, increases. When the radiant floor cooling system or the combination of radiant floor and panel cooling systems without uniform air velocity field is applied, the Category C is verified for some occupants. However, with a convective uniform air velocity field of 0.2 m/s the Category B is verified and with a convective uniform air velocity field of 0.6 m/s the Category A is verify for some occupants. In the last situation the Category C is verified, in general, for all occupants. (C) 2010 Elsevier Inc. All rights reserved

    Performance evaluation of ductless personalized ventilation in comparison with desk fans using numerical simulations

    Get PDF
    The performance of ductless personalized ventilation (DPV) was compared to the performance of a typical desk fan since they are both stand-alone systems that allow the users to personalize their indoor environment. The two systems were evaluated using a validated computational fluid dynamics (CFD) model of an office room occupied by two users. To investigate the impact of DPV and the fan on the inhaled air quality, two types of contamination sources were modelled in the domain: an active source and a passive source. Additionally, the influence of the compared systems on thermal comfort was assessed using the coupling of CFD with the comfort model developed by the University of California, Berkeley (UCB model). Results indicated that DPV performed generally better than the desk fan. It provided better thermal comfort and showed a superior performance in removing the exhaled contaminants. However, the desk fan performed better in removing the contaminants emitted from a passive source near the floor level. This indicates that the performance of DPV and desk fans depends highly on the location of the contamination source. Moreover, the simulations showed that both systems increased the spread of exhaled contamination when used by the source occupant

    Thermal comfort and indoor air quality on end-user satisfaction level evaluation in a Nearly Zero Carbon neighbourhood

    Get PDF
    End-user satisfaction studies in residential buildings has to be approached combining the user’s perspective and technical criteria to consider the complex interactions influencing the building energy performance. Therefore, in this study the physical characteristics of dwellings and their environments are assessed, user satisfaction is examined, and the relationship between them is investigated. The study aims to illustrate the end-user satisfaction in exemplary high performance buildings and to investigate how the users are interacting with these buildings. Examination of the building performance, thermal comfort and indoor air quality are the main focal points of the work. In general, results reflect a significant improvement on the satisfaction level of the inhabitants with the comfort of the dwelling after the refurbishment of the district. Findings from the cross-analysis of both surveys and measurements are used to further refine conclusions and identify the driving factors of the interrelationship between building performance and end-user satisfaction
    corecore