9,008 research outputs found
Monte Carlo-based Noise Compensation in Coil Intensity Corrected Endorectal MRI
Background: Prostate cancer is one of the most common forms of cancer found
in males making early diagnosis important. Magnetic resonance imaging (MRI) has
been useful in visualizing and localizing tumor candidates and with the use of
endorectal coils (ERC), the signal-to-noise ratio (SNR) can be improved. The
coils introduce intensity inhomogeneities and the surface coil intensity
correction built into MRI scanners is used to reduce these inhomogeneities.
However, the correction typically performed at the MRI scanner level leads to
noise amplification and noise level variations. Methods: In this study, we
introduce a new Monte Carlo-based noise compensation approach for coil
intensity corrected endorectal MRI which allows for effective noise
compensation and preservation of details within the prostate. The approach
accounts for the ERC SNR profile via a spatially-adaptive noise model for
correcting non-stationary noise variations. Such a method is useful
particularly for improving the image quality of coil intensity corrected
endorectal MRI data performed at the MRI scanner level and when the original
raw data is not available. Results: SNR and contrast-to-noise ratio (CNR)
analysis in patient experiments demonstrate an average improvement of 11.7 dB
and 11.2 dB respectively over uncorrected endorectal MRI, and provides strong
performance when compared to existing approaches. Conclusions: A new noise
compensation method was developed for the purpose of improving the quality of
coil intensity corrected endorectal MRI data performed at the MRI scanner
level. We illustrate that promising noise compensation performance can be
achieved for the proposed approach, which is particularly important for
processing coil intensity corrected endorectal MRI data performed at the MRI
scanner level and when the original raw data is not available.Comment: 23 page
Shaped extensions of singular spectrum analysis
Extensions of singular spectrum analysis (SSA) for processing of
non-rectangular images and time series with gaps are considered. A circular
version is suggested, which allows application of the method to the data given
on a circle or on a cylinder, e.g. cylindrical projection of a 3D ellipsoid.
The constructed Shaped SSA method with planar or circular topology is able to
produce low-rank approximations for images of complex shapes. Together with
Shaped SSA, a shaped version of the subspace-based ESPRIT method for frequency
estimation is developed. Examples of 2D circular SSA and 2D Shaped ESPRIT are
presented
Space-Varying Coefficient Models for Brain Imaging
The methodological development and the application in this paper originate from diffusion tensor imaging (DTI), a powerful nuclear magnetic resonance technique enabling diagnosis and monitoring of several diseases as well as reconstruction of neural pathways. We reformulate the current analysis framework of separate voxelwise regressions as a 3d space-varying coefficient model (VCM) for the entire set of DTI images recorded on a 3d grid of voxels. Hence by allowing to borrow strength from spatially adjacent voxels, to smooth noisy observations, and to estimate diffusion tensors at any location within the brain, the three-step cascade of standard data processing is overcome simultaneously. We conceptualize two VCM variants based on B-spline basis functions: a full tensor product approach and a sequential approximation, rendering the VCM numerically and computationally feasible even for the huge dimension of the joint model in a realistic setup. A simulation study shows that both approaches outperform the standard method of voxelwise regressions with subsequent regularization. Due to major efficacy, we apply the sequential method to a clinical DTI data set and demonstrate the inherent ability of increasing the rigid grid resolution by evaluating the incorporated basis functions at intermediate points. In conclusion, the suggested fitting methods clearly improve the current state-of-the-art, but ameloriation of local adaptivity remains desirable
Medical imaging analysis with artificial neural networks
Given that neural networks have been widely reported in the research community of medical imaging, we provide a focused literature survey on recent neural network developments in computer-aided diagnosis, medical image segmentation and edge detection towards visual content analysis, and medical image registration for its pre-processing and post-processing, with the aims of increasing awareness of how neural networks can be applied to these areas and to provide a foundation for further research and practical development. Representative techniques and algorithms are explained in detail to provide inspiring examples illustrating: (i) how a known neural network with fixed structure and training procedure could be applied to resolve a medical imaging problem; (ii) how medical images could be analysed, processed, and characterised by neural networks; and (iii) how neural networks could be expanded further to resolve problems relevant to medical imaging. In the concluding section, a highlight of comparisons among many neural network applications is included to provide a global view on computational intelligence with neural networks in medical imaging
- …