114 research outputs found
DE-NOISING ECG SIGNALS CONTAMINATED WITH POWER LINE INTERFERENCE USING NOTCH PRE-FILTERED WAVELET
This paper presents the fusion of Notch filter and Wavelet Transform method for denoising ECG signals contaminated with Power line interference. The objective results are compared qualitatively as well as quantitatively while the effectiveness of the method is also validated by Comparing the obtained results with traditional notch filters as well as the wavelet denoising method. The simulation results demonstrate that the purposed method is most effective for removal of power line interference in terms of fast time convergence as well as less complexity of the deployed algorithm. 
Motion Artifact Processing Techniques for Physiological Signals
The combination of reducing birth rate and increasing life expectancy continues to drive
the demographic shift toward an ageing population and this is placing an ever-increasing
burden on our healthcare systems. The urgent need to address this so called healthcare
\time bomb" has led to a rapid growth in research into ubiquitous, pervasive and
distributed healthcare technologies where recent advances in signal acquisition, data
storage and communication are helping such systems become a reality. However, similar
to recordings performed in the hospital environment, artifacts continue to be a major
issue for these systems. The magnitude and frequency of artifacts can vary signicantly
depending on the recording environment with one of the major contributions due to
the motion of the subject or the recording transducer. As such, this thesis addresses
the challenges of the removal of this motion artifact removal from various physiological
signals.
The preliminary investigations focus on artifact identication and the tagging of physiological
signals streams with measures of signal quality. A new method for quantifying
signal quality is developed based on the use of inexpensive accelerometers which facilitates
the appropriate use of artifact processing methods as needed. These artifact
processing methods are thoroughly examined as part of a comprehensive review of the
most commonly applicable methods. This review forms the basis for the comparative
studies subsequently presented. Then, a simple but novel experimental methodology
for the comparison of artifact processing techniques is proposed, designed and tested
for algorithm evaluation. The method is demonstrated to be highly eective for the
type of artifact challenges common in a connected health setting, particularly those concerned
with brain activity monitoring. This research primarily focuses on applying the
techniques to functional near infrared spectroscopy (fNIRS) and electroencephalography
(EEG) data due to their high susceptibility to contamination by subject motion related
artifact.
Using the novel experimental methodology, complemented with simulated data, a comprehensive
comparison of a range of artifact processing methods is conducted, allowing
the identication of the set of the best performing methods. A novel artifact removal
technique is also developed, namely ensemble empirical mode decomposition with canonical
correlation analysis (EEMD-CCA), which provides the best results when applied on
fNIRS data under particular conditions. Four of the best performing techniques were
then tested on real ambulatory EEG data contaminated with movement artifacts comparable
to those observed during in-home monitoring.
It was determined that when analysing EEG data, the Wiener lter is consistently
the best performing artifact removal technique. However, when employing the fNIRS
data, the best technique depends on a number of factors including: 1) the availability
of a reference signal and 2) whether or not the form of the artifact is known. It is
envisaged that the use of physiological signal monitoring for patient healthcare will grow
signicantly over the next number of decades and it is hoped that this thesis will aid in
the progression and development of artifact removal techniques capable of supporting
this growth
Design of a Simulator for Neonatal Multichannel EEG: Application to Time-Frequency Approaches for Automatic Artifact Removal and Seizure Detection
The electroencephalogram (EEG) is used to noninvasively monitor brain activities; it is the most utilized tool to detect abnormalities such as seizures.
In recent studies, detection of neonatal EEG seizures has been automated to assist neurophysiologists in diagnosing EEG as manual detection is time consuming and subjective; however it still lacks the necessary robustness that is required for clinical implementation. Moreover, as EEG is intended to record the cerebral activities, extra-cerebral activities external to the brain are also recorded; these are called “artifacts” and can seriously degrade the accuracy of seizure detection.
Seizures are one of the most common neurologic problems managed by hospitals occurring in 0.1%-0.5% livebirths. Neonates with seizures are at higher risk for mortality and are reported to be 55-70 times more likely to have severe cerebral-palsy. Therefore, early and accurate detection of neonatal seizures is important to prevent long-term neurological damage.
Several attempts in modelling the neonatal EEG and artifacts have been done, but most did not consider the multichannel case. Furthermore, these models were used to test artifact or seizure detection separately, but not together. This study aims to design synthetic models that generate clean or corrupted multichannel EEG to test the accuracy of available artifact and seizure detection algorithms in a controlled environment.
In this thesis, synthetic neonatal EEG model is constructed by using; single-channel EEG simulators, head model, 21-electrodes, and propagation equations, to produce clean multichannel EEG. Furthermore, neonatal EEG artifact model is designed using synthetic signals to corrupt EEG waveforms. After that, an automated EEG artifact detection and removal system is designed in both time and time-frequency domains. Artifact detection is optimised and removal performance is evaluated. Finally, an automated seizure detection technique is developed, utilising fused and extended multichannel features along a cross-validated SVM classifier.
Results show that the synthetic EEG model mimics real neonatal EEG with 0.62 average correlation, and corrupted-EEG can degrade seizure detection average accuracy from 100% to 70.9%. They also show that using artifact detection and removal enhances the average accuracy to 89.6%, and utilising the extended features enhances it to 97.4% and strengthened its robustness.لمراقبة ورصد أنشطة واشارات المخ، دون الحاجة لأي عملیات (EEG) یستخدم الرسم أو التخطیط الكھربائي للدماغ
للدماغجراحیة، وھي تعد الأداة الأكثر استخداما في الكشف عن أي شذوذأو نوبات غیر طبیعیة مثل نوبات الصرع. وقد أظھرت دراسات حدیثة، أن الكشف الآلي لنوبات حدیثي الولادة، ساعد علماء الفسیولوجیا العصبیة في تشخیص الاشارات الدماغیة بشكل أكبر من الكشف الیدوي، حیث أن الكشف الیدوي یحتاج إلى وقت وجھد أكبر وھوذو فعالیة أقل بكثیر، إلا أنھ لا یزال یفتقر إلى المتانة الضروریة والمطلوبة للتطبیق السریري.علاوة على ذلك؛ فكما یقوم الرسم الكھربائي بتسجیل الأنشطة والإشارات الدماغیة الداخلیة، فھو یسجل أیضا أي نشاط أو اشارات خارجیة، مما یؤدي إلى -(artifacts) :حدوث خلل في مدى دقة وفعالیة الكشف عن النوبات الدماغیة الداخلیة، ویطلق على تلك الاشارات مسمى (نتاج صنعي) . 0.5٪ولادة حدیثة في -٪تعد نوبات الصرع من أكثر المشكلات العصبیة انتشارا،ً وھي تصیب ما یقارب 0.1المستشفیات. حیث أن حدیثي الولادة المصابین بنوبات الصرع ھم أكثر عرضة للوفاة، وكما تشیر التقاریر الى أنھم 70مرة أكثر. لذا یعد الكشف المبكر والدقیق للنوبات الدماغیة -معرضین للإصابة بالشلل الدماغي الشدید بما یقارب 55لحدیثي الولادة مھم جدا لمنع الضرر العصبي على المدى الطویل. لقد تم القیام بالعدید من المحاولات التي كانتتھدف الى تصمیم نموذج التخطیط الكھربائي والنتاج الصنعي لدماغ حدیثي الولادة, إلا أن معظمھا لم یعر أي اھتمام الى قضیة تعدد القنوات. إضافة الى ذلك, استخدمت ھذه النماذج , كل على حدة, أو نوبات الصرع. تھدف ھذه الدراسة الى تصمیم نماذج مصطنعة من شأنھا (artifact) لإختبار كاشفات النتاج الصنعيأن تولد اشارات دماغیة متعددة القنوات سلیمة أو معطلة وذلك لفحص مدى دقة فعالیة خوارزمیات الكشف عن نوبات ضمن بیئة یمكن السیطرة علیھا. (artifact) الصرع و النتاج الصنعي في ھذه الأطروحة, یتكون نموذج الرسم الكھربائي المصطنع لحدیثي الولادة من : قناة محاكاة واحده للرسم الكھربائي, نموذج رأس, 21قطب كھربائي و معادلات إنتشار. حیث تھدف جمیعھا لإنتاج إشاراة سلیمة متعدده القنوات للتخطیط عن طریق استخدام اشارات مصطنعة (artifact) الكھربائي للدماغ.علاوة على ذلك, لقد تم تصمیم نموذجالنتاج الصنعيفي نطاقالوقت و (artifact) لإتلاف الرسم الكھربائي للدماغ. بعد ذلك تم انشاء برنامج لكشف و إزالةالنتاج الصناعينطاقالوقت و التردد المشترك. تم تحسین برنامج الكشف النتاج الصناعيالى ابعد ما یمكن بینما تمت عملیة تقییم أداء الإزالة. وفي الختام تم التمكن من تطویر تقنیة الكشف الآلي عن نوبات الصرع, وذلك بتوظیف صفات مدمجة و صفات الذي تم التأكد من صحتھ. (SVM) جدیدة للقنوات المتعددة لإستخدامھا للمصنفلقد أظھرت النتائج أن نموذج الرسم الكھربائي المصطنع لحدیثي الولادة یحاكي الرسمالكھربائي الحقیقي لحدیثي الولادة بمتوسط ترابط 0.62, و أنالرسم الكھربائي المتضرر للدماغ قد یؤدي الى حدوث ھبوطفي مدى دقة متوسط الكشف عن نوبات الصرع من 100%الى 70.9%. وقد أشارت أیضا الى أن استخدام الكشف والإزالة عن النتاج الصنعي (artifact) یؤدي الى تحسن مستوى الدقة الى نسبة 89.6 %, وأن توظیف الصفات الجدیدة للقنوات المتعددة یزید من
تحسنھا لتصل الى نسبة 94.4 % مما یعمل على دعم متانتھا
Recommended from our members
Advanced robust non-invasive foetal heart detection techniques during active labour using one pair of transabdominal electrodes
The thesis proposes and evaluates three state-of-the-art signal processing techniques to detect fetal heartbeats within each maternal cardiac cycle, during labour contractions, using only a pair of transabdominal electrodes. The first and second techniques are, namely, the structured third- order cumulant-slice-template matching and the bispectral-contours-template matching for fetal QRS identification, respectively. The third technique is based on the modified and appropriately weighted spectral multiple signal classification (MUSIC) with incorporated covariance matrix for uterine contraction noise-like interfering signals also contaminated with noise. Essentially, two modifications to the standard MUSIC have been developed in order to enhance the performance of the spectral estimator in our applied work. The first modification involves the introduction of an optimised weighting function to the segmented ECG covariance matrix, and is chiefly aimed at enhancing the fetal QRS major spectral peak which occurs at around 30 Hz against the mother QRS major spectral peak usually occurring around 17 Hz and all other noise contributions. Additional optional pseudo-bispectral enhancement to sharpen the maternal and fetal spectral peaks, in particular when the mother and fetal R-waves are temporally coincident, have been achieved. The second modification to the spectral MUSIC is the removal of the unjustified assumption that only white Gaussian noise is present and the incorporation of the actual measured labour uterine contraction covariance matrix in reconfigured subspace analysis. This inevitably leads to the generalised eigenvectors - eigenvalues decomposition modern signal processing. This is now coined the modified, interference incorporated pseudo-spectral MUSIC. The above mentioned first and second techniques are higher-order statistics-based (HOS) and hybrid involving both signal processing and NN classifiers. The third technique is second-order statistics-based (SOS). In all techniques, the removal of signal non-linearity with the aid of non-linear Volterra synthesisers plays a crucial part in the fetal detection integrity.
Accurately assessed fetal heart classification rates as high as 95% have been achieved during labour, thus helping to provide non-invasive transparency to fetal intrapartum welfare. Performance analysis and evaluation processes involved more than 30 critical cases classified as “fetal under stress in labour” recorded in a London hospital database and used both transbadominal ECG electrodes and fetal scalp electrodes. The latter facilitates detection of the instantaneous fetal heart rate which is then used as the Reference Fetal Heart Rate in the assessment of the classification rate of each of the above mentioned techniques. It will be shown that the fetal heartbeats are completely masked by uterine activity and noise artefacts in all the recorded transabdominal maternal ECG signals. The fetal scalp electrode was, therefore, deemed necessary to provide the highest accurate measure of fetal heart functionality (from the hospital viewpoint), and in the assessment of the three non-invasive techniques presented in this thesis. The techniques may also be used during gestation and as early as 10 weeks
Acoustic Condition Monitoring & Fault Diagnostics for Industrial Systems
Condition monitoring and fault diagnostics for industrial systems is required for cost reduction, maintenance scheduling, and reducing system failures. Catastrophic failure usually causes significant damage and may cause injury or fatality, making early and accurate fault diagnostics of paramount importance. Existing diagnostics can be improved by augmenting or replacing with acoustic measurements, which have proven advantages over more traditional vibration measurements including, earlier detection of emerging faults, increased diagnostic accuracy, remote sensors and easier setup and operation. However, industry adoption of acoustics remains in relative infancy due to vested confidence and reliance on existing measurement and, perceived difficulties with noise contamination and diagnostic accuracy. Researched acoustic monitoring examples typically employ specialist surface-mount transducers, signal amplification, and complex feature extraction and machine learning algorithms, focusing on noise rejection and fault classification. Usually, techniques are fine-tuned to maximise diagnostic performance for the given problem. The majority investigate mechanical fault modes, particularly Roller Element Bearings (REBs), owing to the mechanical impacts producing detectable acoustic waves. The first contribution of this project is a suitability study into the use of low-cost consumer-grade acoustic sensors for fault diagnostics of six different REB health conditions, comparing against vibration measurements. Experimental results demonstrate superior acoustic performance throughout but particularly at lower rotational speed and axial load. Additionally, inaccuracies caused by dynamic operational parameters (speed in this case), are minimised by novel multi-Support Vector Machine training. The project then expands on existing work to encompass diagnostics for a previously unreported electrical fault mode present on a Brush-Less Direct Current motor drive system. Commonly studied electrical faults, such as a broken rotor bar or squirrel cage, result from mechanical component damage artificially seeded and not spontaneous. Here, electrical fault modes are differentiated as faults caused by issues with the power supply, control system or software (not requiring mechanical damage or triggering intervention). An example studied here is a transient current instability, generated by non-linear interaction of the motor electrical parameters, parasitic components and digital controller realisation. Experimental trials successfully demonstrate real-time feature extraction and further validate consumer-grade sensors for industrial system diagnostics. Moreover, this marks the first known diagnosis of an electrically-seeded fault mode as defined in this work. Finally, approaching an industry-ready diagnostic system, the newly released PYNQ-Z2 Field Programmable Gate Array is used to implement the first known instance of multiple feature extraction algorithms that operate concurrently in continuous real-time. A proposed deep-learning algorithm can analyse the features to determine the optimum feature extraction combination for ongoing continuous monitoring. The proposed black-box, all-in-one solution, is capable of accurate unsupervised diagnostics on almost any application, maintaining excellent diagnostic performance. This marks a major leap forward from fine-tuned feature extraction performed offline for artificially seeded mechanical defects to multiple real-time feature extraction demonstrated on a spontaneous electrical fault mode with a versatile and adaptable system that is low-cost, readily available, with simple setup and operation. The presented concept represents an industry-ready all-in-one acoustic diagnostic solution, that is hoped to increase adoption of acoustic methods, greatly improving diagnostics and minimising catastrophic failures
Towards Patient-Specific Brain Networks Using Functional Magnetic Resonance Imaging
fMRI applications are rare in translational medicine and clinical practice. What can be inferred from a single fMRI scan is often unreliable due to the relative low signal-to-noise ratio compared to other neuroimaging modalities. However, the potential of fMRI is promising. It is one of the few neuroimaging modalities to obtain functional brain organisation of an individual during task engagement and rest. This work extends on current fMRI image processing approaches to obtain robust estimates of functional brain organisation in two resting-state fMRI cohorts. The first cohort comprises of young adults who were born at extremely low gestations and age-matched healthy controls. Group analysis between term- and preterm-born adults revealed differences in functional organisation, which were discovered to be predominantly caused by underlying structural and physiological differences. The second cohort comprises of elderly adults with young onset Alzheimer’s disease and age-matched controls. Their corresponding resting-state fMRI scans are short in scanning time resulting in unreliable spatial estimates with conventional dual regression analysis. This problem was addressed by the development of an ensemble averaging of matrix factorisations approach to compute single subject spatial maps characterised by improved spatial reproducibility compared to maps obtained by dual regression. The approach was extended with a haemodynamic forward model to obtain surrogate neural activations to examine the subject’s task behaviour. This approach applied to two task-fMRI cohorts showed that these surrogate neural activations matched with original task timings in most of the examined fMRI scans but also revealed subjects with task behaviour different than intended by the researcher. It is hoped that both the findings in this work and the novel matrix factorisation approach itself will benefit the fMRI community. To this end, the derived tools are made available online to aid development and validation of methods for resting-state and task fMRI experiments
- …