A pressure switch assembly comprising a body portion and a switch mechanism having a contact element operable between opposite limit positions is described. A diaphragm chamber is provided in the body portion which mounts therein a system diaphragm and a calibration diaphragm which are of generally the same configuration and having outer faces conforming to the inner and outer walls of the diaphragm chamber. The space between the inner faces of the diaphragms defines a first chamber section and the space between the outer face of one of the diaphragms and the outer wall of the diaphragm chamber defines a second chamber section. The body portion includes a system pressure port communicating with one of the chamber sections and a calibration pressure port communicating with the other chamber section. An actuator connected to one of the diaphragms and the contact element of the switch operates upon pressure change in the diaphragm sections to move said contact element between limit positions
TFE coating extends life of flexible metal compressor diaphragm
Tetrafluoroethylene /TFE/ aerosol sprayed onto entire surface of diaphragm acts as film lubricant and permits diaphragm to slide between upper and lower plates in a reciprocating compressor. Flexing occurs over an area rather than about a single line of action and operating life of diaphragm is more than quadrupled
Flexible parylene actuator for micro adaptive flow control
This paper describes the first flexible parylene electrostatic actuator valves intended for micro adaptive flow control for the future use on the wings of micro-air-vehicle (MAV). The actuator diaphragm is made of two layers of parylene membranes with offset vent holes. Without electrostatic actuation, air can move freely from one side of the skin to the other side through the vent holes. With actuation, these vent holes are sealed and the airflow is controlled. The membrane behaves as a complete diaphragm.
We have successfully demonstrated this function using a 2-mm x 2-mm parylene diaphragm electrostatic actuator valves. This work also includes the novel anti-stiction technology that is crucial to make such large-area parylene actuator diaphragm with the combined use of anti-stiction posts, self-assembled monolayers (SAM), surface roughening, and bromine trifluoride (BrFe) dry etching. With the help of SAM treatment, the operating voltage is lowered from 30 volts to 13 volts. The load deflection method is then used to measure the effective thickness of the composite
diaphragm. The flexible parylene diaphragm can be deflected up to 100 μm when 150 Torr of pressure is applied. The result is fitted into a theoretical model and yields an effective thickness of 5.9 μm, which is agreeable with the actual thickness of 5.6 μm, thus proves the functionality of the device
Early phrenic motor neuron loss and transient respiratory abnormalities following unilateral cervical spinal cord contusion
Contusion-type cervical spinal cord injury (SCI) is one of the most common forms of SCI observed in patients. In particular, injuries targeting the C3-C5 region affect the pool of phrenic motor neurons (PhMNs) that innervates the diaphragm, resulting in significant and often chronic respiratory dysfunction. Using a previously described rat model of unilateral midcervical C4 contusion with the Infinite Horizon Impactor, we have characterized the early time course of PhMN degeneration and consequent respiratory deficits following injury, as this knowledge is important for designing relevant treatment strategies targeting protection and plasticity of PhMN circuitry. PhMN loss (48% of the ipsilateral pool) occurred almost entirely during the first 24 h post-injury, resulting in persistent phrenic nerve axonal degeneration and denervation at the diaphragm neuromuscular junction (NMJ). Reduced diaphragm compound muscle action potential amplitudes following phrenic nerve stimulation were observed as early as the first day post-injury (30% of pre-injury maximum amplitude), with slow functional improvement over time that was associated with partial reinnervation at the diaphragm NMJ. Consistent with ipsilateral diaphragmatic compromise, the injury resulted in rapid, yet only transient, changes in overall ventilatory parameters measured via whole-body plethysmography, including increased respiratory rate, decreased tidal volume, and decreased peak inspiratory flow. Despite significant ipsilateral PhMN loss, the respiratory system has the capacity to quickly compensate for partially impaired hemidiaphragm function, suggesting that C4 hemicontusion in rats is a model of SCI that manifests subacute respiratory abnormalities. Collectively, these findings demonstrate significant and persistent diaphragm compromise in a clinically relevant model of midcervical contusion SCI; however, the therapeutic window for PhMN protection is restricted to early time points post-injury. On the contrary, preventing loss of innervation by PhMNs and/or inducing plasticity in spared PhMN axons at the diaphragm NMJ are relevant long-term targets
The effect of hypodynamia on the structure of the intraorganic blood vessels and the capacity of the blood stream in the diaphragm of white rats
The effect of hypodynamia on the vascular system of white rats with diaphragm deprivation was investigated. Morphological changes in the intraorganic blood stream of the diaphragm were determined. The capacity of the intraorganic vascular flow within the diaphragm muscles was established
Sex differences in exercise-induced diaphragmatic fatigue in endurance-trained athletes
There is evidence that female athletes may be more susceptible to exercise-induced arterial hypoxemia and expiratory flow limitation and have greater increases in operational lung volumes during exercise relative to men. These pulmonary limitations may ultimately lead to greater levels of diaphragmatic fatigue in women. Accordingly, the purpose of this study was to determine whether there are sex differences in the prevalence and severity of exercise-induced diaphragmatic fatigue in 38 healthy endurance-trained men (n = 19; maximal aerobic capacity = 64.0 ± 1.9 ml·kg–1·min–1) and women (n = 19; maximal aerobic capacity = 57.1 ± 1.5 ml·kg–1·min–1). Transdiaphragmatic pressure (Pdi) was calculated as the difference between gastric and esophageal pressures. Inspiratory pressure-time products of the diaphragm and esophagus were calculated as the product of breathing frequency and the Pdi and esophageal pressure time integrals, respectively. Cervical magnetic stimulation was used to measure potentiated Pdi twitches (Pdi,tw) before and 10, 30, and 60 min after a constant-load cycling test performed at 90% of peak work rate until exhaustion. Diaphragm fatigue was considered present if there was a 15% reduction in Pdi,tw after exercise. Diaphragm fatigue occurred in 11 of 19 men (58%) and 8 of 19 women (42%). The percent drop in Pdi,tw at 10, 30, and 60 min after exercise in men (n = 11) was 30.6 ± 2.3, 20.7 ± 3.2, and 13.3 ± 4.5%, respectively, whereas results in women (n = 8) were 21.0 ± 2.1, 11.6 ± 2.9, and 9.7 ± 4.2%, respectively, with sex differences occurring at 10 and 30 min (P < 0.05). Men continued to have a reduced contribution of the diaphragm to total inspiratory force output (pressure-time product of the diaphragm/pressure-time product of the esophagus) during exercise, whereas diaphragmatic contribution in women changed very little over time. The findings from this study point to a female diaphragm that is more resistant to fatigue relative to their male counterparts
Liquid pump for astronaut cooling
The Apollo portable life support system water-recirculation pump used for astronaut cooling is described. The problems associated with an early centrifugal pump and how these problems were overcome by the use of a new diaphragm pump are discussed. Performance comparisons of the two pump designs are given. Developmental problems and flight results with the diaphragm pump are discussed
A monitoring device for pressurised-air-driven diaphragm-based artificial heart assist devices
A non-invasive device has been developed to monitor the diaphragm position and the blood flow in artificial heart assist devices equipped with a pressurised-air-driven diaphragm. Light scattering from the diaphragm is used as a mechanism for measuring. Information about the position of several points of the diaphragm can be obtained. The completely empty or filled situation can be detected and used for control purposes. Flow data can be extracted and bending characteristics of the diaphragm during operation can be studied
Burst diaphragm flow initiator Patent
Burst diaphragm flow initiator for installation in short duration wind tunnel
The influence of tensile forces on the deflection of circular diaphragms in pressure sensors
It is known that the deflection of a diaphragm is determined by two mechanisms, bending moments or bending stress and tensile forces or membrane stress.\ud
\ud
Usually the influence of tensile forces is not taken into account when calculating the mechanical properties of thin diaphragms. Hence the mathematical description thus obtained will only be valid if the deflection of the diaphragm is small compared with its thickness and if lateral stress is absent.\ud
\ud
In this paper we will consider uniformly loaded circular diaphragms, which are assumed to be isotropic, and present the results of a study on the influence of bending stress and tensile stress, which together determine the diaphragm deflection.\ud
\ud
Starting from theoretical considerations, a simulation program is developed of which several results are presented and discussed
- …