    Advances to Electrode Pullback in Cochlear Implant Surgery

    Get PDF
    Objective. To observe the intracochlear behavior of a cochlear implant electrode insertion technique (called "pullback") in temporal bones. Study Design. Experimental. Settings. Tertiary referral center. Method. The change of the intracochlear electrode position was investigated under various conditions of an electrode pullback (N = 54) in 9 radiologically, size-estimated temporal bones (TBs). Those TBs were prepared by removal of the cochlear scalar roof to apply digital video capture procedures to monitor the pullback procedures. The digitally captured pictures were analyzed with specific software. Results. An optimal pullback of the electrode varied between 1.37 mm and 2.67 mm. While a limited pullback is without risk, an extended pullback bears the risk of removing the electrode tip out of its initial position or out of the cochlea. A correlation between cochlear size and the amount of pullback was not found. Conclusion. An initial insertion to the first or the second marker on the electrode followed by a limited pullback of about 1.37 mm to 1.5 mm can be recommended to achieve an optimized perimodiolar position. A pullback of up to two marker positions bears the risk of removing the electrode tip out of its initial position

    Toward steerable electrodes: an overview of concepts and current research

    Get PDF
    Restoration of hearing is a demanding surgical task which requires the insertion of a cochlear implant electrode array into the inner ear while preserving the delicate basilar membrane inside the cochlea for an atraumatic insertion. Already shortly after the first clinical success with early versions of cochlear implants the desire for a controlled insertion of the electrode array arose. Such a steerable electrode should be in its shape adaptable to the individual path of the helical inner ear in order to avoid any contact between the implant and the surrounding tissue. This article provides a short overview of concepts and actuator mechanisms investigated in the past and present with the objective of developing a steerable electrode array for an individualized insertion process. Although none of these concepts has reached clinical implementation, there are promising experimental results indicating that insertion forces can be reduced up to 60% compared to straight and not steerable electrodes. Finally, related research topics are listed which require considerable further improvements until steerable electrodes will reach clinical applicability

    Individual Optimization of the Insertion of a Preformed Cochlear Implant Electrode Array

    Get PDF
    Purpose. The aim of this study was to show that individual adjustment of the curling behaviour of a preformed cochlear implant (CI) electrode array to the patient-specific shape of the cochlea can improve the insertion process in terms of reduced risk of insertion trauma. Methods. Geometry and curling behaviour of preformed, commercially available electrode arrays were modelled. Additionally, the anatomy of each small, medium-sized, and large human cochlea was modelled to consider anatomical variations. Finally, using a custom-made simulation tool, three different insertion strategies (conventional Advanced Off-Stylet (AOS) insertion technique, an automated implementation of the AOS technique, and a manually optimized insertion process) were simulated and compared with respect to the risk of insertion-related trauma. The risk of trauma was evaluated using a newly developed “trauma risk” rating scale. Results. Using this simulation-based approach, it was shown that an individually optimized insertion procedure is advantageous compared with the AOS insertion technique. Conclusion. This finding leads to the conclusion that, in general, consideration of the specific curling behaviour of a CI electrode array is beneficial in terms of less traumatic insertion. Therefore, these results highlight an entirely novel aspect of clinical application of preformed perimodiolar electrode arrays in general
    corecore