4 research outputs found
Design and Optimization Methods for Pin-Limited and Cyberphysical Digital Microfluidic Biochips
<p>Microfluidic biochips have now come of age, with applications to biomolecular recognition for high-throughput DNA sequencing, immunoassays, and point-of-care clinical diagnostics. In particular, digital microfluidic biochips, which use electrowetting-on-dielectric to manipulate discrete droplets (or "packets of biochemical payload") of picoliter volumes under clock control, are especially promising. The potential applications of biochips include real-time analysis for biochemical reagents, clinical diagnostics, flash chemistry, and on-chip DNA sequencing. The ease of reconfigurability and software-based control in digital microfluidics has motivated research on various aspects of automated chip design and optimization.</p><p>This thesis research is focused on facilitating advances in on-chip bioassays, enhancing the automated use of digital microfluidic biochips, and developing an "intelligent" microfluidic system that has the capability of making on-line re-synthesis while a bioassay is being executed. This thesis includes the concept of a "cyberphysical microfluidic biochip" based on the digital microfluidics hardware platform and on-chip sensing technique. In such a biochip, the control software, on-chip sensing, and the microfluidic operations are tightly coupled. The status of the droplets is dynamically monitored by on-chip sensors. If an error is detected, the control software performs dynamic re-synthesis procedure and error recovery.</p><p>In order to minimize the size and cost of the system, a hardware-assisted error-recovery method, which relies on an error dictionary for rapid error recovery, is also presented. The error-recovery procedure is controlled by a finite-state-machine implemented on a field-programmable gate array (FPGA) instead of a software running on a separate computer. Each state of the FSM represents a possible error that may occur on the biochip; for each of these errors, the corresponding sequence of error-recovery signals is stored inside the memory of the FPGA before the bioassay is conducted. When an error occurs, the FSM transitions from one state to another, and the corresponding control signals are updated. Therefore, by using inexpensive FPGA, a portable cyberphysical system can be implemented.</p><p>In addition to errors in fluid-handling operations, bioassay outcomes can also be erroneous due the uncertainty in the completion time for fluidic operations. Due to the inherent randomness of biochemical reactions, the time required to complete each step of the bioassay is a random variable. To address this issue, a new "operation-interdependence-aware" synthesis algorithm is proposed in this thesis. The start and stop time of each operation are dynamically determined based on feedback from the on-chip sensors. Unlike previous synthesis algorithms that execute bioassays based on pre-determined start and end times of each operation, the proposed method facilitates "self-adaptive" bioassays on cyberphysical microfluidic biochips.</p><p>Another design problem addressed in this thesis is the development of a layout-design algorithm that can minimize the interference between devices on a biochip. A probabilistic model for the polymerase chain reaction (PCR) has been developed; based on the model, the control software can make on-line decisions regarding the number of thermal cycles that must be performed during PCR. Therefore, PCR can be controlled more precisely using cyberphysical integration.</p><p>To reduce the fabrication cost of biochips, yet maintain application flexibility, the concept of a "general-purpose pin-limited biochip" is proposed. Using a graph model for pin-assignment, we develop the theoretical basis and a heuristic algorithm to generate optimized pin-assignment configurations. The associated scheduling algorithm for on-chip biochemistry synthesis has also been developed. Based on the theoretical framework, a complete design flow for pin-limited cyberphysical microfluidic biochips is presented.</p><p>In summary, this thesis research has led to an algorithmic infrastructure and optimization tools for cyberphysical system design and technology demonstrations. The results of this thesis research are expected to enable the hardware/software co-design of a new class of digital microfluidic biochips with tight coupling between microfluidics, sensors, and control software.</p>Dissertatio
A Framework for Automated Correctness Checking of Biochemical Protocol Realizations on Digital Microfluidic Biochips
Recent advances in digital microfluidic (DMF) technologies offer a promising
platform for a wide variety of biochemical applications, such as DNA analysis,
automated drug discovery, and toxicity monitoring. For on-chip implementation
of complex bioassays, automated synthesis tools have been developed to meet the
design challenges. Currently, the synthesis tools pass through a number of
complex design steps to realize a given biochemical protocol on a target DMF
architecture. Thus, design errors can arise during the synthesis steps. Before
deploying a DMF biochip on a safety critical system, it is necessary to ensure
that the desired biochemical protocol has been correctly implemented, i.e., the
synthesized output (actuation sequences for the biochip) is free from any
design or realization errors. We propose a symbolic constraint-based analysis
framework for checking the correctness of a synthesized biochemical protocol
with respect to the original design specification. The verification scheme
based on this framework can detect several post-synthesis fluidic violations
and realization errors in 2D-array based or pin-constrained biochips as well as
in cyberphysical systems. It further generates diagnostic feedback for error
localization. We present experimental results on the polymerase chain reaction
(PCR) and in-vitro multiplexed bioassays to demonstrate the proposed
verification approach
Recommended from our members
BioScript: programming safe chemistry on laboratories-on-a-chip
This paper introduces BioScript, a domain-specific language (DSL) for programmable biochemistry which executes on emerging microfluidic platforms. The goal of this research is to provide a simple, intuitive, and type-safe DSL that is accessible to life science practitioners. The novel feature of the language is its syntax, which aims to optimize human readability; the technical contributions of the paper include the BioScript type system and relevant portions of its compiler. The type system ensures that certain types of errors, specific to biochemistry, do not occur, including the interaction of chemicals that may be unsafe. The compiler includes novel optimizations that place biochemical operations to execute concurrently on a spatial 2D array platform on the granularity of a control flow graph, as opposed to individual basic blocks. Results are obtained using both a cycle-accurate microfluidic simulator and a software interface to a real-world platform