5 research outputs found

    MEMS micromirrors for imaging applications

    Get PDF
    Strathclyde theses - ask staff. Thesis no. : T13478Optical MEMS (microelectromechanical systems) are widely used in various applications. In this thesis, the design, simulation and characterisation of two optical MEMS devices for imaging applications, a varifocal micromirror and a 2D scanning micromirror, are introduced. Both devices have been fabricated using the commercial Silicon-on-Insulator multi-users MEMS processes (SOIMUMPs), in the 10 m thick Silicon-on-Insulator (SOI) wafer. Optical MEMS device with variable focal length is a critical component for imaging system miniaturisation. In this thesis, a thermally-actuated varifocal micromirror (VFM) with 1-mm-diameter aperture is introduced. The electrothermal actuation through Joule heating of the micromirror suspensions and the optothermal actuation using incident laser power absorption have been demonstrated as well as finite element method (FEM) simulation comparisons. Especially, the optical aberrations produced by this VFM have been statistically quantified to be negligible throughout the actuation range. A compact imaging system incorporating this VFM has been demonstrated with high quality imaging results. MEMS 2D scanners, or scanning micromirrors, are another type of optical MEMS which have been widely investigated for applications such as biomedical microscope imaging, projection, retinal display and optical switches for telecommunication network, etc. For large and fast scanning motions, the actuation scheme to scan a micromirror in two axes, the structural connections and arrangement are fundamental. The microscanner introduced utilises two types of actuators, electrothermal actuators and electrostatic comb-drives, to scan a 1.2-mm-diameter gold coated silicon micromirror in two orthogonal axes. With assistance of FEM software, CoventorWare, the structure optimisation of actuators and flexure connections are presented. The maximum optical scan angles in two axes by each type of actuator individually and by actuating the two at the same time have been characterised experimentally. By programming actuation signals, the microscanner has achieved a rectangular scan pattern with 7° 10° angular-scan-field at a line-scan rate of around 1656 Hz.Optical MEMS (microelectromechanical systems) are widely used in various applications. In this thesis, the design, simulation and characterisation of two optical MEMS devices for imaging applications, a varifocal micromirror and a 2D scanning micromirror, are introduced. Both devices have been fabricated using the commercial Silicon-on-Insulator multi-users MEMS processes (SOIMUMPs), in the 10 m thick Silicon-on-Insulator (SOI) wafer. Optical MEMS device with variable focal length is a critical component for imaging system miniaturisation. In this thesis, a thermally-actuated varifocal micromirror (VFM) with 1-mm-diameter aperture is introduced. The electrothermal actuation through Joule heating of the micromirror suspensions and the optothermal actuation using incident laser power absorption have been demonstrated as well as finite element method (FEM) simulation comparisons. Especially, the optical aberrations produced by this VFM have been statistically quantified to be negligible throughout the actuation range. A compact imaging system incorporating this VFM has been demonstrated with high quality imaging results. MEMS 2D scanners, or scanning micromirrors, are another type of optical MEMS which have been widely investigated for applications such as biomedical microscope imaging, projection, retinal display and optical switches for telecommunication network, etc. For large and fast scanning motions, the actuation scheme to scan a micromirror in two axes, the structural connections and arrangement are fundamental. The microscanner introduced utilises two types of actuators, electrothermal actuators and electrostatic comb-drives, to scan a 1.2-mm-diameter gold coated silicon micromirror in two orthogonal axes. With assistance of FEM software, CoventorWare, the structure optimisation of actuators and flexure connections are presented. The maximum optical scan angles in two axes by each type of actuator individually and by actuating the two at the same time have been characterised experimentally. By programming actuation signals, the microscanner has achieved a rectangular scan pattern with 7° 10° angular-scan-field at a line-scan rate of around 1656 Hz

    Visible and Mid-Infrared Supercontinuum Generation and Their Respective Application to 3D imaging and Stand-off Reflection Spectroscopy.

    Full text link
    The thesis describes broadband supercontinuum (SC) generation in optical fibers for both the visible and mid-infrared regions of the spectrum, and their respective application to 3D imaging and stand-off reflection spectroscopy. Both SC sources leverage mature telecom technology, and are based on a common all-fiber integrated platform comprising a ~1.55 micron distributed feedback seed laser diode amplified to high peak powers in two stages of cladding pumped Erbium or Erbium-Ytterbium fiber amplifiers. A visible SC extending from 0.45-1.20 microns with 0.74 W of time-averaged power is demonstrated using a two step process. The output of the Er-Yb power amplifier is frequency doubled to ~0.78 micron using a periodically poled lithium niobate crystal, followed by non-linear spectral broadening in 2m of high nonlinearity photonic crystal fiber. Numerical simulations based on solving the generalized non-linear Schrödinger equation are also presented to verify the underlying SC generation mechanisms and predict further improvements. The above SC source is used in a Fourier domain line scan interferometer to measure the height and identify shape defects of ~300 micron high solder balls in a ball grid array. The 3D imaging system has an axial resolution of ~125 nm, transverse resolution of ~15 microns, and an angular measurement range between 20 to 60 degrees depending on the sample surface roughness. The mid-infrared SC source is generated by pumping a 9m long ZrF4-BaF2-LaF3-AlF3-NaF (ZBLAN) fiber to obtain a spectrum spanning 0.8-4.3 microns with 3.9 W time-averaged power. The output power is linearly scalable with pump power, but requires optimization of the critical splices and thermal management of the gain fiber and pump diodes to ensure stable high power operation. Finally, an application of the mid-IR SC is demonstrated by measuring the diffuse reflection spectra of solid samples at a stand-off distance of 5 m and 100 ms integration time. The samples can be distinguished using a correlation algorithm based on distinct spectral features in the reflection spectrum. Signal to noise ratio calculations show that the distance is limited by space constraints in our lab and can be extended to ~150 m.Ph.D.Electrical EngineeringUniversity of Michigan, Horace H. Rackham School of Graduate Studieshttp://deepblue.lib.umich.edu/bitstream/2027.42/89708/1/malayk_1.pd

    MEMS Technology for Biomedical Imaging Applications

    Get PDF
    Biomedical imaging is the key technique and process to create informative images of the human body or other organic structures for clinical purposes or medical science. Micro-electro-mechanical systems (MEMS) technology has demonstrated enormous potential in biomedical imaging applications due to its outstanding advantages of, for instance, miniaturization, high speed, higher resolution, and convenience of batch fabrication. There are many advancements and breakthroughs developing in the academic community, and there are a few challenges raised accordingly upon the designs, structures, fabrication, integration, and applications of MEMS for all kinds of biomedical imaging. This Special Issue aims to collate and showcase research papers, short commutations, perspectives, and insightful review articles from esteemed colleagues that demonstrate: (1) original works on the topic of MEMS components or devices based on various kinds of mechanisms for biomedical imaging; and (2) new developments and potentials of applying MEMS technology of any kind in biomedical imaging. The objective of this special session is to provide insightful information regarding the technological advancements for the researchers in the community

    Microfluidics and Nanofluidics Handbook

    Get PDF
    The Microfluidics and Nanofluidics Handbook: Two-Volume Set comprehensively captures the cross-disciplinary breadth of the fields of micro- and nanofluidics, which encompass the biological sciences, chemistry, physics and engineering applications. To fill the knowledge gap between engineering and the basic sciences, the editors pulled together key individuals, well known in their respective areas, to author chapters that help graduate students, scientists, and practicing engineers understand the overall area of microfluidics and nanofluidics. Topics covered include Finite Volume Method for Numerical Simulation Lattice Boltzmann Method and Its Applications in Microfluidics Microparticle and Nanoparticle Manipulation Methane Solubility Enhancement in Water Confined to Nanoscale Pores Volume Two: Fabrication, Implementation, and Applications focuses on topics related to experimental and numerical methods. It also covers fabrication and applications in a variety of areas, from aerospace to biological systems. Reflecting the inherent nature of microfluidics and nanofluidics, the book includes as much interdisciplinary knowledge as possible. It provides the fundamental science background for newcomers and advanced techniques and concepts for experienced researchers and professionals

    EUROSENSORS XVII : book of abstracts

    Get PDF
    Fundação Calouste Gulbenkien (FCG).Fundação para a Ciência e a Tecnologia (FCT)
    corecore