187 research outputs found

    Robotic-Assisted Systems for Spinal Surgery

    Get PDF
    Robotic-assisted spinal surgery is in its infancy. It aims to improve the accuracy of screw placement, lower the risk of surgical complications, and reduce radiation exposure to the patient and the surgical team. The present chapter attempts to provide an overview of the evolution of robotic-assisted spinal surgery and highlights different commercially available spine robotic systems in present use. The review concludes with future applications of robotics in spinal surgery

    The Accuracy of Patient-Specific Spinal Drill Guides Is Non-Inferior to Computer-Assisted Surgery:The Results of a Split-Spine Randomized Controlled Trial

    Get PDF
    In recent years, patient-specific spinal drill guides (3DPGs) have gained widespread popularity. Several studies have shown that the accuracy of screw insertion with these guides is superior to that obtained using the freehand insertion technique, but there are no studies that make a comparison with computer-assisted surgery (CAS). The aim of this study was to determine whether the accuracy of insertion of spinal screws using 3DPGs is non-inferior to insertion via CAS. A randomized controlled split-spine study was performed in which 3DPG and CAS were randomly assigned to the left or right sides of the spines of patients undergoing fixation surgery. The 3D measured accuracy of screw insertion was the primary study outcome parameter. Sixty screws inserted in 10 patients who completed the study protocol were used for the non-inferiority analysis. The non-inferiority of 3DPG was demonstrated for entry-point accuracy, as the upper margin of the 95% CI (−1.01 mm–0.49 mm) for the difference between the means did not cross the predetermined non-inferiority margin of 1 mm (p < 0.05). We also demonstrated non-inferiority of 3D angular accuracy (p < 0.05), with a 95% CI for the true difference of −2.30◦–1.35◦, not crossing the predetermined non-inferiority margin of 3◦ (p < 0.05). The results of this randomized controlled trial (RCT) showed that 3DPGs provide a non-inferior alternative to CAS in terms of screw insertion accuracy and have considerable potential as a navigational technique in spinal fixation

    Augmented reality navigation for spinal pedicle screw instrumentation using intraoperative 3D imaging

    Get PDF
    BACKGROUND CONTEXT Due to recent developments in augmented reality with head-mounted devices, holograms of a surgical plan can be displayed directly in the surgeon's field of view. To the best of our knowledge, three dimensional (3D) intraoperative fluoroscopy has not been explored for the use with holographic navigation by head-mounted devices in spine surgery. PURPOSE To evaluate the surgical accuracy of holographic pedicle screw navigation by head-mounted device using 3D intraoperative fluoroscopy. STUDY DESIGN In this experimental cadaver study, the accuracy of surgical navigation using a head-mounted device was compared with navigation with a state-of-the-art pose-tracking system. METHODS Three lumbar cadaver spines were embedded in nontransparent agar gel, leaving only commonly visible anatomy in sight. Intraoperative registration of preoperative planning was achieved by 3D fluoroscopy and fiducial markers attached to lumbar vertebrae. Trackable custom-made drill sleeve guides enabled real-time navigation. In total, 20 K-wires were navigated into lumbar pedicles using AR-navigation, 10 K-wires by the state-of-the-art pose-tracking system. 3D models obtained from postexperimental CT scans were used to measure surgical accuracy. MF is the founder and shareholder of Incremed AG, a Balgrist University Hospital start-up focusing on the development of innovative techniques for surgical executions. The other authors declare no conflict of interest concerning the contents of this study. No external funding was received for this study. RESULTS No significant difference in accuracy was measured between AR-navigated drillings and the gold standard with pose-tracking system with mean translational errors between entry points (3D vector distance; p=.85) of 3.4±1.6 mm compared with 3.2±2.0 mm, and mean angular errors between trajectories (3D angle; p=.30) of 4.3°±2.3° compared with 3.5°±1.4°. CONCLUSIONS In conclusion, holographic navigation by use of a head-mounted device achieve accuracy comparable to the gold standard of high-end pose-tracking systems. CLINICAL SIGNIFICANCE These promising results could result in a new way of surgical navigation with minimal infrastructural requirements but now have to be confirmed in clinical studies

    Assessment of Surgical Procedural Time, Pedicle Screw Accuracy, and Clinician Radiation Exposure of a Novel Robotic Navigation System Compared With Conventional Open and Percutaneous Freehand Techniques: A Cadaveric Investigation

    Get PDF
    STUDY DESIGN: Cadaveric study. OBJECTIVE: To evaluate accuracy, radiation exposure, and surgical time of a new robotic-assisted navigation (RAN) platform compared with freehand techniques in conventional open and percutaneous procedures. METHODS: Ten board-certified surgeons inserted 16 pedicle screws at T10-L5 (n = 40 per technique) in 10 human cadaveric torsos. Pedicle screws were inserted with (1) conventional MIS technique (L2-L5, patient left pedicles), (2) MIS RAN (L2-L5, patient right pedicles), (3) conventional open technique (T10-L1, patient left pedicles), and (4) open RAN (T10-L1, patient right pedicles). Output included (1) operative time, (2) number of fluoroscopic images, and (3) screw accuracy. RESULTS: In the MIS group, compared with the freehand technique, RAN allowed for use of larger screws (diameter: 6.6 ± 0.6 mm vs 6.3 ± 0.5 mm; length: 50.3 ± 4.1 mm vs 46.9 ± 3.5 mm), decreased the number of breaches \u3e2 mm (0 vs 7), fewer fluoroscopic images (0 ± 0 vs 108.3 ± 30.9), and surgical procedure time per screw (3.6 ± 0.4 minutes vs 7.6 ± 2.0 minutes) (all CONCLUSION: RAN significantly improved accuracy and decreased radiation exposure in comparison to freehand techniques in both conventional open and percutaneous surgical procedures in cadavers. RAN significantly increased setup time compared with both conventional procedures

    Miniature Robotic Guidance for Spine Surgery

    Get PDF

    Accuracy Assessment of Pedicle and Lateral Mass Screw Insertion Assisted by Customized 3D-Printed Drill Guides:A Human Cadaver Study

    Get PDF
    BACKGROUND: Accurate cervical screw insertion is of paramount importance considering the risk of damage to adjacent vital structures. Recent research in 3-dimensional (3D) technology describes the advantage of patient-specific drill guides for accurate screw positioning, but consensus about the optimal guide design and the accuracy is lacking. OBJECTIVE: To find the optimal design and to evaluate the accuracy of individualized 3D-printed drill guides for lateral mass and pedicle screw placement in the cervical and upper thoracic spine. METHODS: Five Thiel-embalmed human cadavers were used for individualized drill-guide planning of 86 screw trajectories in the cervical and upper thoracic spine. Using 3D bone models reconstructed from acquired computed tomography scans, the drill guides were produced for both pedicle and lateral mass screw trajectories. During the study, the initial minimalistic design was refined, resulting in the advanced guide design. Screw trajectories were drilled and the realized trajectories were compared to the planned trajectories using 3D deviation analysis. RESULTS: The overall entry point and 3D angular accuracy were 0.76 +/- 0.52 mm and 3.22 +/- 2.34 degrees, respectively. Average measurements for the minimalistic guides were 1.20 mm for entry points, 5.61 degrees for the 3D angulation, 2.38 degrees for the 2D axial angulation, and 4.80 degrees for the 2D sagittal angulation. For the advanced guides, the respective measurements were 0.66 mm, 2.72 degrees, 1.26 degrees, and 2.12 degrees, respectively. CONCLUSION: The study ultimately resulted in an advanced guide design including caudally positioned hooks, crosslink support structure, and metal inlays. The novel advanced drill guide design yields excellent drilling accuracy

    Clinical Accuracy of Three-Dimensional Fluoroscopy (IsoC-3D)-Assisted Upper Thoracic Pedicle Screw Insertion

    Get PDF
    Correct screw placement is especially difficult in the upper thoracic vertebrae. At the cervicothoracic junction (C7-T2), problems can arise because of the narrowness of the pedicle and the difficulty of using a lateral image intensifier there. Other upper thoracic vertebrae (T3-6) pose a problem for screw insertion also because of the narrower pedicle. We inserted 154 pedicle screws into 78 vertebrae (C7 to T6) in 38 patients. Screws were placed using intraoperative data acquisition by an isocentric C-arm fluoroscope (Siremobile Iso-C3D) and computer navigation. Out of 90 pedicle screws inserted into 45 vertebrae between C7 and T2, 87 of the 90 (96.7%) screws were classified as grade 1 (no perforation). Of 64 pedicle screws inserted into 33 vertebrae between T3 and T6, 61 of 64 (95.3%) screws were classified as grade 1. In this study, we reduced pedicle screw misplacement at the level of the C7 and upper thoracic (T1-6) vertebrae using the three-dimensional fluoroscopy navigation system

    Patient-specific 3D-printed surgical guides for pedicle screw insertion: comparison of different guide design approaches

    Get PDF
    AIM: Patient-specific 3D-printed guides for pedicle screw insertion in spinal deformity surgery offer an alternative to image-guided, robotic and free-hand methods. Different design features can impact their accuracy and clinical applicability. The aim of this study was to compare the performance of three different guide designs with the nonguided free-hand technique. MATERIAL & METHODS: 3D-printed guides were design and tested using anatomical models of human spines and porcine cadaveric specimens. Three different guided groups (low, medium and full contact) and one nonguided group was formed. RESULTS & CONCLUSIONS: The design approach affected level of accuracy of screw placement. A variability in terms of accuracy of screw insertion between surgeon’s experience using nonguided/guided techniques was also observed, suggesting benefit for junior surgeons in improving surgical accuracy