209,899 research outputs found
Effective optimal design of 3-D magnetic device having complicated coil using edge element and Biot-Savart method
It is troublesome and time consuming to treat a coil of complicated shape with optimization methods using edge elements, because the current vector potential in the coil of changed shape (changed mesh) should be calculated at each iteration of the optimization. In this paper, an effective optimal design method using the Biot-Savart method (As method) and the evolution strategy is investigated. As it is not necessary to generate a mesh for the coil by using the As method, the mesh becomes simple and, moreover, it is not necessary to calculate the current vector potential in the changed coil at each iteration in order to give the current vector potential in the coil. The usefulness of the proposed method is illustrated by applying it to the optimal design of a deflection coil for a cathode-ray tube</p
Investigation of evolution strategy and optimization of induction heating model
An optimal design method using the finite element method and the evolution strategy (ES) is investigated. The evolution strategy is applied to the optimization of induction heating model. The position of auxiliary coil, frequency and ampere-turns are optimized so that the distribution of eddy current density on the surface of steel becomes uniform. It is shown that the selection of the appropriate parameter is important in the practical application of ES</p
Minimax Current Density Coil Design
'Coil design' is an inverse problem in which arrangements of wire are
designed to generate a prescribed magnetic field when energized with electric
current. The design of gradient and shim coils for magnetic resonance imaging
(MRI) are important examples of coil design. The magnetic fields that these
coils generate are usually required to be both strong and accurate. Other
electromagnetic properties of the coils, such as inductance, may be considered
in the design process, which becomes an optimization problem. The maximum
current density is additionally optimized in this work and the resultant coils
are investigated for performance and practicality. Coils with minimax current
density were found to exhibit maximally spread wires and may help disperse
localized regions of Joule heating. They also produce the highest possible
magnetic field strength per unit current for any given surface and wire size.
Three different flavours of boundary element method that employ different basis
functions (triangular elements with uniform current, cylindrical elements with
sinusoidal current and conic section elements with sinusoidal-uniform current)
were used with this approach to illustrate its generality.Comment: 24 pages, 6 figures, 2 tables. To appear in Journal of Physics D:
Applied Physic
NMR shim coil design utilising a rapid spherical harmonic calculation method
A rapid spherical harmonic calculation method is used for the design of Nuclear Magnetic Resonance shim coils. The aim is to design each shim such that it generates a field described purely by a single spherical harmonic. By applying simulated annealing techniques, coil arrangements are produced through the optimal positioning of current-carrying circular arc conductors of rectangular cross-section. This involves minimizing the undesirable harmonies in relation to a target harmonic. The design method is flexible enough to be applied for the production of coil arrangements that generate fields consisting significantly of either zonal or tesseral harmonics. Results are presented for several coil designs which generate tesseral harmonics of degree one
Simulation of multi-deck medium temperature display cabinets with the integration of CFD and cooling coil models
This is the post-print version of the final paper published in Applied Energy. The published article is available from the link below. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. Copyright @ 2010 Elsevier B.V.In this paper, the model for the multi-deck medium temperature display cabinets is developed with the integration of CFD and cooling coil sub-models. The distributed method is used to develop the cooling coil model with the airside inputs from the outputs of the CFD model. Inversely, the airside outputs from the cooling coil model are used to update the boundary conditions of the CFD model. To validate this cabinet model, a multi-deck medium temperature display cabinet refrigerated with a secondary refrigerant cooling coil was selected as a prototype and mounted in an air conditioned chamber. Extensive tests were conducted at constant space air temperature and varied relative humilities. The cabinet model has been validated by comparing with the test results for the parameters of air at different locations of the flow path, and temperatures of refrigerant and food product, etc. The validated model is therefore used to explore and analyse the cabinet performance and control strategies at various operating and design conditions.DEFR
Development of 1 MJ Conduction-Cooled LTS Pulse Coil for UPS-SMES
A 1 MW, 1 s UPS-SMES is being developed for a protection from a momentary voltage drop and an instant power failure. As a key technology of the UPS-SMES, we developed a prototype LTS pulse coil with a stored energy of 100 kJ and conducted cooling and excitation tests in 2005. The operation test of the prototype UPS-SMES using this 100 kJ coil with power converters have been performed in 2006. A 1 MJ coil was designed before the fabrication of the 100 kJ prototype coil. The superconductor, the electric insulation technique, the winding method, and the cooling structure used for the 100 kJ coil were based upon the 1 MJ coil design. The successful performance test results of the prototype 100 kJ coil validated the design concept and fabrication technique of the 1 MJ coil. According to the achievement of the prototype 100 kJ UPS-SMES, the 1 MJ conduction-cooled LTS pulse coil has been fabricated successfully. The successful experimental results of the 100 kJ prototype coil with power converters and the fabrication procedure of the 1 MJ full size coil are described
Design and Realization of Measuring Coils for Diagnostics Quantity of Nanoparticles in Kerosene and Identifying of Type Natural Oil
The first part describes the design of the coil to detect the concentration of iron oxide nanoparticles (0.0 % to 0.5 %) in the kerosene sample using the impedance spectroscopy method. Test coil was designed for detecting and measuring the amount of particles in the experimental design for connection to an analyzer 4294As frequency range of 40 Hz to 110 MHz. Then the samples were measured in a resonator using a wave analyzer with a frequency range of 10 MHz to 20 GHz. In view of good results, this methodology was applied to the detection and recognition of different types of oils
Design of wideband vibration-based electromagnetic generator by means of dual-resonator
This paper describes the design of a wideband electromagnetic energy harvester that utilizes a novel dual-resonator method to improve the operational frequency range of the vibration-based generator. The device consists of two separate resonator systems (coil and magnet), which each comply with their respective resonance frequencies. This is because both resonators are designed in such a way that both magnet and coil components will oscillate at an additive phase angle, and hence create greater relative motion between the two dominating resonance frequencies, which realizes the wideband generator. Each resonator system consists of a distinctive cantilever beam, one attached with four magnets and steel keepers, the other attached with a copper coil and stainless steel holder as the free end mass. Both cantilevers are clamped and fitted to a common base that is subjected to a vibration source. Basic analytical models are derived and a numerical model is implemented in MATLAB-Simulink. Electromagnetic, structural modal and static mechanical analysis for the design of the prototype are completed using ANSYS finite element tools. For a 0.8 m s−2 acceleration, the open-loop voltage obtained from the experiment shows a good correlation with those from the simulation. Peak induced voltage is measured to be 259.5Vrms as compared to 240.9Vrms from the simulator at 21.3 Hz, which implies an error range of 7.7%. The results also indicate that there is a maximum of 58.22% improvement in the induced voltage within the intermediate region which occurs at the intersection point between the output response plots of two single resonator generators
- …