3 research outputs found

    Retinal Blood Vessel Segmentation Algorithm for Diabetic Retinopathy using Wavelet: A Survey

    Get PDF
    Blood vessel structure in retinal images have an important role in diagnosis of diabetic retinopathy. There are several method present for automatic retinal vessel segmentation. For developing retinal screening systems blood vessel segmentation is the basic foundation since vessels serve as one of the main retinal landmark features. The most common signs of diabetic retinopathy include hemorrhages, cotton wool spots, dilated retinal veins, and hard exudates. A patient with diabetic retinopathy disease has to undergo periodic screening of eye. For the diagnosis, doctors use color retinal images of a patient required from digital fundus camera. We present a method that uses Gabor wavelet for vessel enhancement due to their ability to enhance directional structures and euclidean distance technique for accurate vessel segmentation. Retinal angiography images are mainly used in the diagnosis of diseases such as diabetic retinopathy and hypertension etc. In diabetic retinopathy structure of retinal blood vessels change that leads to adult blindness. To overcome this problem automatic biomedical diagnosis system is required.The main stage of diabetic retinopathy are Non-proliferative diabetic retinopathy (NPDR) and proliferative diabetic retinopathy (PDR). Eye care specialist can screen vessel abnormalities using an efficient and effective computer based approach to the automated segmentation of blood vessels in retinal images. Automated segmentation reduces the time required by a physician or a skilled technician for manual labeling. Thus a reliable method of vessel segmentation would be valuable for the early detection and characterization of changes due to such diseases. This article presents the automated vessel enhancement and segmentation technique for colored retinal images. Segmentation of blood vessels from image is a difficult task due to thin vessels and low contrast between vessel edges and background. The proposed method enhances the vascular pattern using Gabor wavelet and then it uses euclidean distance technique to generate gray level segmented image. DOI: 10.17762/ijritcc2321-8169.15030

    Computer Vision Based Early Intraocular Pressure Assessment From Frontal Eye Images

    Get PDF
    Intraocular Pressure (IOP) in general, refers to the pressure in the eyes. Gradual increase of IOP and high IOP are conditions or symptoms that may lead to certain diseases such as glaucoma, and therefore, must be closely monitored. While the pressure in the eye increases, different parts of the eye may become affected until the eye parts are damaged. An effective way to prevent rise in eye pressure is by early detection. Exiting IOP monitoring tools include eye tests at clinical facilities and computer-aided techniques from fundus and optic nerves images. In this work, a new computer vision-based smart healthcare framework is presented to evaluate the intraocular pressure risk from frontal eye images early-on. The framework determines the status of IOP by analyzing frontal eye images using image processing and machine learning techniques. A database of images from the Princess Basma Hospital was used in this work. The database contains 400 eye images; 200 images with normal IOP and 200 high eye pressure case images. This study proposes novel features for IOP determination from two experiments. The first experiment extracts the sclera using circular hough transform, after which four features are extracted from the whole sclera. These features are mean redness level, red area percentage, contour area and contour height. The pupil/iris diameter ratio feature is also extracted from the frontal eye image after a series of pre-processing techniques. The second experiment extracts the sclera and iris segment using a fully conventional neural network technique, after which six features are extracted from only part of the segmented sclera and iris. The features include mean redness level, red area percentage, contour area, contour distance and contour angle along with the pupil/iris diameter ratio. Once the features are extracted, classification techniques are applied in order to train and test the images and features to obtain the status of the patients in terms of eye pressure. For the first experiment, neural network and support vector machine algorithms were adopted in order to detect the status of intraocular pressure. The second experiment adopted support vector machine and decision tree algorithms to detect the status of intraocular pressure. For both experiments, the framework detects the status of IOP (normal or high IOP) with high accuracies. This computer vison-based approach produces evidence of the relationship between the extracted frontal eye image features and IOP, which has not been previously investigated through automated image processing and machine learning techniques from frontal eye images

    BLOOD VESSEL DIAMETER MEASUREMENT ON RETINAL IMAGE

    No full text
    corecore