7 research outputs found

    Detection of interictal epileptiform discharges: A comparison of on-scalp MEG and conventional MEG measurements

    Get PDF
    Objective: Conventional MEG provides an unsurpassed ability to, non-invasively, detect epileptic activity. However, highly resolved information on small neuronal populations required in epilepsy diagnostics is lost and can be detected only intracranially. Next-generation on-scalp magnetencephalography (MEG) sensors aim to retrieve information unavailable to conventional non-invasive brain imaging techniques. To evaluate the benefits of on-scalp MEG in epilepsy, we performed the first-ever such measurement on an epilepsy patient. Methods: Conducted as a benchmarking study focusing on interictal epileptiform discharge (IED) detectability, an on-scalp high-temperature superconducting quantum interference device magnetometer (high-Tc SQUID) system was compared to a conventional, low-temperature SQUID system. Coregistration of electroencephalopraphy (EEG) was performed. A novel machine learning-based IED-detection algorithm was developed to aid identification of on-scalp MEG unique IEDs. Results: Conventional MEG contained 24 IEDs. On-scalp MEG revealed 47 IEDs (16 co-registered by EEG, 31 unique to the on-scalp MEG recording). Conclusion: Our results indicate that on-scalp MEG might capture IEDs not seen by other non-invasive modalities. Significance: On-scalp MEG has the potential of improving non-invasive epilepsy evaluation. (C) 2020 International Federation of Clinical Neurophysiology. Published by Elsevier B.V

    On-scalp MEG sensor localization using magnetic dipole-like coils: A method for highly accurate co-registration

    Get PDF
    Source modelling in magnetoencephalography (MEG) requires precise co-registration of the sensor array and the anatomical structure of the measured individual\u27s head. In conventional MEG, the positions and orientations of the sensors relative to each other are fixed and known beforehand, requiring only localization of the head relative to the sensor array. Since the sensors in on-scalp MEG are positioned on the scalp, locations of the individual sensors depend on the subject\u27s head shape and size. The positions and orientations of on-scalp sensors must therefore be measured a every recording. This can be achieved by inverting conventional head localization, localizing the sensors relative to the head - rather than the other way around. In this study we present a practical method for localizing sensors using magnetic dipole-like coils attached to the subject\u27s head. We implement and evaluate the method in a set of on-scalp MEG recordings using a 7-channel on-scalp MEG system based on high critical temperature superconducting quantum interference devices (high-T-c SQUIDs). The method allows individually localizing the sensor positions, orientations, and responsivities with high accuracy using only a short averaging time (<= 2 mm, < 3 degrees and < 3%, respectively, with 1-s averaging), enabling continuous sensor localization. Calibrating and jointly localizing the sensor array can further improve the accuracy of position and orientation (< 1 mm and < 1 degrees, respectively, with 1-s coil recordings). We demonstrate source localization of on-scalp recorded somatosensory evoked activity based on coregistration with our method. Equivalent current dipole fits of the evoked responses corresponded well (within 4.2 mm) with those based on a commercial, whole-head MEG system

    On mapping epilepsy : magneto- and electroencephalographic characterizations of epileptic activities

    Get PDF
    Epilepsy is one of the most common neurological disorder, affecting up to 10 individuals per 1000 persons. The disorder have been known for several thousand years, with the first clinical descriptions dating back to ancient times. Nonetheless, characterization of the dynamics underlying epilepsy remains largely unknown. Understanding these patophysiological processes requires unifying both a neurobiological perspective, as well as a technically advanced neuroimaging perspective. The incomplete insight into epilepsy dynamics is reflected by the insufficient treatment options. Approximately 30% of all patients do not respond to anti-epileptic drugs (AEDs) and thus suffers from recurrent seizures despite adequate pharmacological treatments. These pharmacoresistant patients often undergo epilepsy surgery evaluations. Epilepsy surgery aims to resect the part of the brain that generates the epileptic seizure activity (seizure onset zone, SOZ). Nonetheless, up to 50% of all patients relapse after surgery. This can be due to incomplete mapping of both the SOZ and of other structures that might be involved in seizure initiation and propagation. Such cortical and subcortical structures are collectively referred to as the epileptic network. Historically, epilepsy was considered to be either a generalized disorder involving the entire brain, or a highly localized, focal, disorder. The modern technological development of both structural and functional neuroimaging has drastically altered this view. This development has made significant contributions to the now prevailing view that both generalized and focal epilepsies arise from more or less widespread pathological network pathways. Visualization of these pathways play an important role in the presurgical planning. Thus, both improved characterization and understanding of such pathways are pivotal in improvement of epilepsy diagnostics and treatments. It is evident that epilepsy research needs to stand on two legs: Both improved understanding of pathological, neurobiological and neurophysiological process, and improved neuroimaging instrumentation. Epilepsy research do not only span from visualization to understanding of neurophysiological processes, but also from cellular, neuronal, microscopic processes, to dynamical, large-scale network processes. It is well known that neurons involved in epileptic activities exhibit specific, pathological firing patterns. Genetic mutations resulting in neuronal ion channel defects can cause severe, and even lethal, epileptic syndromes in children, clearly illustrating a role for neuron membrane properties in epilepsy. However, cellular processes themselves cannot explain how epileptic seizures can involve, and propagate across, large cortical areas and generate seizure-specific symptomatologies. A strict cellular perspective can neither explain epilepsy-associated pathological interactions between larger distant regions in between seizures. Instead, the dynamical effects of cellular synchronization across both mesoscopic and macroscopic scales also need to be considered. Today, the only means to study such effects in human subjects are by combinations of neuroimaging modalities. However, as all measurement techniques, these exhibit individual limitations that affect the kind of information that can be inferred from these. Thus, once more we reach the conclusion that epilepsy research needs to rest upon both a neurophysiological/neurobiological leg, and a technical/instrumentational leg. In accordance with this necessity of a dual approach to epilepsy, this thesis covers both neurophysiological aspects of epileptic activity development, as well as functional neuroimaging instrumentation development with focus on epileptic activity detection and localization. Part 1 (neurophysiological part) is concerned with the neurophysiological dynamical changes that underlie development of so called interictal epileptiform discharges (IEDs) with special focus on the role of low-frequency oscillations. To this aim, both conventional magnetoencephalography (MEG) and intracranial electroencephalography (iEEG) with neurostimulation is analyzed. Part 2 (instrumentation part) is concerned with development of cutting-edge, novel on-scalp magnetoencephalography (osMEG) within clinical epilepsy evaluations and research with special focus on IEDs. The theses cover both modeling of osMEG characteristics, as well as the first-ever osMEG recording of a temporal lobe epilepsy patient

    On-scalp MEG using high-Tc SQUIDs: Measuring brain activity with superconducting magnetometers

    Get PDF
    This thesis describes work done towards realizing on-scalp magnetoencephalography (MEG) based on high critical temperature (high-Tc) superconducting quantum interference device (SQUID) sensors. MEG is a non-invasive neuroimaging modality that records the magnetic fields produced by neural currents with good spatial and high temporal resolution. However, state-of-the-art MEG is limited by the use of liquid helium-cooled sensors (T ~ 4 K). The amount of thermal insulation between the sensors and the subject\u27s head that is required to achieve the extreme temperature difference (~300 K), typically realized in the form of superinsulation foil and ~2 centimeters of vacuum, limits measurable signals. Replacing the sensors with high-Tc SQUIDs can mitigate this problem. High-Tc SQUIDs operate at much higher temperatures (90 K) allowing significant reduction of the stand-off distance (to ~1 mm). They can furthermore be cooled with liquid nitrogen (77 K), a cheaper, more sustainable alternative to the liquid helium used for cooling in conventional MEG systems.The work described in this thesis can be divided into three main areas: (I) simulation work for practical implementations of on-scalp systems, (II) development of a 7-channel high-Tc SQUID-based on-scalp MEG system, and (III) on-scalp MEG recordings.In the first part, spatial information density (SID), a metric to evaluate the performance of simulated MEG sensor arrays, is introduced and - along with total information capacity - used to compare the performance of various simulated full-head on-scalp MEG sensor arrays.\ua0Simulations demonstrate the potential of on-scalp MEG, with all on-scalp systems exhibiting higher information capacity than the state-of-the-art. SID further reveals more homogeneous sampling of the brain with flexible systems. A method for localizing magnetometers in on-scalp MEG systems is introduced and tested in simulations. The method uses small, magnetic dipole-like coils to determine the location and orientation of individual sensors, enabling straightforward co-registration in flexible on-scalp MEG systems. The effects of different uncertainties and errors on the accuracy of the method were quantified.In the second part, design, construction, and performance of a 7-channel on-scalp MEG system is described. The system houses seven densely-packed (2 mm edge-to-edge), head-aligned high-Tc SQUID magnetometers (9.2 mm x 8.6 mm) inside a single, liquid nitrogen-cooled cryostat. With a single filling, the system can be utilized for MEG recordings for >16 h with low noise levels (~0-130 fT). Using synchronized clocks and a direct injection feedback scheme, the system achieves low sensor crosstalk (<0.6%).\ua0In the third part, on-scalp MEG recordings with the 7-channel system as well as its predecessor, a single-channel system, are presented. The recordings are divided into proof-of-principle and benchmarking experiments. The former consist of well-studied, simple paradigms such as auditory evoked activity and visual alpha. Expected signal components were clearly seen in the on-scalp recordings. The benchmarking studies were done to compare and contrast on-scalp with state-of-the-art MEG. To this end, a number of experimental stimulus paradigms were recorded on human subjects with the high-Tc SQUID-based on-scalp systems as well as a state-of-the-art, commercial full-head MEG system. Results include the expected signal gains that are associated with recording on-scalp as well as new details of the neurophysiological signals. Using the previously described on-scalp MEG co-registration method enabled source localization with high agreement to the full-head recording (the distance between dipoles localized with the two systems was 4.2 mm)

    Manufatura aditiva no fabrico de células de vapor de metal alcalino para magnetoencefalografia

    Get PDF
    Dissertação de mestrado em Engenharia BiomédicaThe magnetoencephalography (MEG) exam is one of the technologies that allows the mapping of brain electrophysiology by recording magnetic fields emanating from the brain. In this technology, the main sensing technology is based on superconducting quantum interference devices (SQUIDs). These bulky devices are expensive to manufacture and maintain, and therefore, optical pumping magnetometers (OPMs) have emerged more recently as magnetic sensing alternatives that are comparable in sensitivity to SQUIDs. The ability to adjust to the patient's head allows us to conceptualize the development of a structure based on this technology, formed by several rubidium (Rb) cells, which is the main component of OPMs. This master's dissertation had as its main objective the development of a Rb vapor cell, through additive manufacturing (AM) techniques, in order to obtain an alternative to the techniques of microelectromechanical systems (MEMS). In the modeling technology by deposition of molten material (FDM), nylon was selected to make up the vapor cell and thermoplastic polyurethane (TPU) to serve as a support structure, while in the AM technology by photopolymerization, a transparent resin. Several iterations of cell design and printing parameters were performed for each material, resulting in a cubic cell measuring 10mm on each edge and with a wall thickness of 0.40mm. The present dissertation also evaluated the effect of the application of various coatings (alumina, sodium silicate and acrylic) on the transmittance and polarization of light, as well as its effect on the tightness of the cell. These tests resulted in a final cell coated externally with acrylic and internally with alumina. Regarding the production of Rb vapour, it was necessary to obtain rubidium azide (RbN3) from the reaction between silver azide (AgN3) and rubidium chloride (RbCl). The introduction of the RbN3 solution into the cell was carried out through a pipetting procedure followed by evaporation of the water. The cell was finally introduced into a vacuum chamber and sealed. The production of Rb vapor was performed by exposing the cell with RbN3 to 254 nm ultraviolet (UV) radiation. The work developed in this dissertation establishes relevant foundations in the development of OPMs by MA.O exame de magnetoencefalografia (MEG) é umas das tecnologias que permite realizar o mapeamento da eletrofisiologia cerebral através do registo de campos magnéticos emanados pelo cérebro. Neste método de diagnóstico a principal tecnologia de sensorização baseia-se nos dispositivos supercondutores de interferência quântica (SQUIDs). Estes dispositivos são volumosos, apresentam um custo de fabrico e manutenção elevados e portanto, os magnetómetros de bombeamento ótico (OPMs) surgem mais recentemente como alternativas de sensorização magnética equiparáveis em sensibilidade aos SQUIDs. A capacidade de ajuste à cabeça do paciente permite conceptualizar o desenvolvimento de uma estrutura baseada nesta tecnologia, formada por várias células de rubídio (Rb), que constitui a principal componente dos OPMs. A presente dissertação de mestrado teve como objetivo principal o desenvolvimento de uma célula de vapor de Rb, através de manufatura aditiva (MA), de forma a obter uma alternativa às técnicas de sistemas microeletromecânicos (MEMS). Na MA de modelação por deposição de material fundido (FDM) selecionou-se o nylon, para perfazer a célula de vapor e o termoplástico poliuretano (TPU), para servir de estrutura de suporte, já na tecnologia de MA por fotopolimerização selecionou-se uma resina transparente. Realizaram-se varias iterações de design da célula e dos parâmetros de impressão de cada material, resultando numa célula cubica de com 10 mm em cada aresta e com 0.40 mm de espessura de parede. A presente dissertação também avaliou o efeito da aplicação de vários revestimentos (alumina, silicato de sódio e acrílico) na transmitância e na polarização da luz, bem o seu efeito na estanquicidade da célula. Este testes resultaram numa célula final revestida externamente com acrílico e internamente com alumina. No que toca à produção de vapor de Rb, foi necessário obter azida de rubídio (RbN3) da reação entre azida de prata (AgN3) com cloreto de rubídio (RbCl). A introdução da solução de RbN3 na célula foi realizada através de um procedimento de pipetação seguida da evaporação da água. A célula foi finalmente introduzida numa câmara de vácuo e selada. A produção de vapor de Rb foi realizada através da exposição da célula com RbN3 a radiação ultravioleta (UV) de 254 nm. O trabalho desenvolvido nesta dissertação estabelece alicerces pertinentes no desenvolvimento de OPMs por MA

    High-temperature superconducting magnetometers for on-scalp MEG

    Get PDF
    In the growing field of on-scalp magnetoencephalography (MEG), brain activity is studied by non-invasively mapping the magnetic fields generated by neuronal currents with sensors that are flexibly placed in close proximity to the subject\u27s head. This thesis focuses on high-temperature superconducting magnetometers made from YBa2Cu3Ox-7 (YBCO), which enables a reduction in the sensor-to-room temperature standoff distance from roughly 2 cm (for conventional MEG systems) down to 1 mm. Because of the higher neuromagnetic signal magnitudes available to on-scalp sensors, simulations predict that even a relatively low-sensitivity (higher noise) full-head on-scalp MEG system can extract more information about brain activity than conventional systems.In the first part of this thesis, the development of high critical temperature (high-Tc) superconducting quantum interference device (SQUID) magnetometers for a 7-channel on-scalp MEG system is described. The sensors are single layer magnetometers with a directly coupled pickup loop made on 10 mm 7 10 mm substrates using bicrystal grain boundary Josephson junctions. We found that the kinetic inductance strongly varies with film quality and temperature. Determination of all SQUID parameters by combining measurements and inductance simulations led to excellent agreement between experimental results and theoretical predictions. This allowed us to perform an in-depth magnetometer optimization. The best magnetometers achieve a magnetic field noise level of 44 fT/√Hz at 78 K. Fabricated test SQUIDs provide evidence that noise levels below 30 fT/√Hz are possible for high quality junctions with fairly low critical currents and in combination with the optimized pickup loop design. Different feedback methods for operation in a densely-packed on-scalp MEG system were also investigated. Direct injection of current into the SQUID loop was identified as the best on-chip feedback method with feedback flux crosstalk below 0.5%. By reducing the operation temperature, the noise level can be further reduced, however, the effective area also decreases because of the decreasing kinetic inductance contribution. We present a method that allows for one-time sensor calibration independent of temperature.In the second part, the design, operation, and performance of the constructed 7-channel on-scalp MEG system based on the fabricated magnetometers is presented. With a dense (2 mm edge-to-edge) hexagonal head-aligned array, the system achieves a small sensor-to-head standoff distance of 1-3 mm and dense spatial sampling. The magnetic field noise levels are 50-130 fT/√Hz and the sensor-to-sensor feedback flux crosstalk is below 0.6%. MEG measurements with the system demonstrate the feasibility of the approach and indicate that our on-scalp MEG system allows retrieval of information unavailable to conventional MEG.In the third part, two alternative magnetometer types are studied for the next generation system. The first alternative is magnetometers based on Dayem bridge junctions instead of bicrystal grain boundary junctions. With a magnetometer based on the novel grooved Dayem bridge junctions, a magnetic field noise level of 63 fT/√Hz could be achieved, which shows that Dayem bridge junctions are starting to become a viable option for single layer magnetometers. The second alternative are high-Tc SQUID magnetometers with an inductively coupled flux transformer. The best device with bicrystal grain boundary junctions reaches a magnetic field noise level below 11 fT/√Hz and outperforms the best single layer device for frequencies above 20 Hz.In the last part, the potential of kinetic inductance magnetometers (KIMs) is investigated. We demonstrate the first high-Tc KIMs, which can be operated in fields of 9-28 \ub5T and achieve a noise level of 4 pT/√Hz at 10 kHz

    Benchmarking for On-Scalp MEG Sensors

    No full text
    OBJECTIVE: We present a benchmarking protocol for quantitatively comparing emerging on-scalp magnetoencephalography (MEG) sensor technologies to their counterparts in state-of-the-art MEG systems. METHODS: As a means of validation, we compare a high-critical-temperature superconducting quantum interference device (high Tc SQUID) with the low- Tc SQUIDs of an Elekta Neuromag TRIUX system in MEG recordings of auditory and somatosensory evoked fields (SEFs) on one human subject. RESULTS: We measure the expected signal gain for the auditory-evoked fields (deeper sources) and notice some unfamiliar features in the on-scalp sensor-based recordings of SEFs (shallower sources). CONCLUSION: The experimental results serve as a proof of principle for the benchmarking protocol. This approach is straightforward, general to various on-scalp MEG sensors, and convenient to use on human subjects. The unexpected features in the SEFs suggest on-scalp MEG sensors may reveal information about neuromagnetic sources that is otherwise difficult to extract from state-of-the-art MEG recordings. SIGNIFICANCE: As the first systematically established on-scalp MEG benchmarking protocol, magnetic sensor developers can employ this method to prove the utility of their technology in MEG recordings. Further exploration of the SEFs with on-scalp MEG sensors may reveal unique information about their sources
    corecore