692,402 research outputs found
Electron beam welder X-rays its own welds
Beam of an electron beam welder X rays its own welds, enabling rapid weld quality checks to be made without removing the work from the vacuum chamber. A tungsten target produces X rays when hit by the beam. They are directed at the weld specimen and recorded on polaroid film
2-kW Average Power CW Phase-Conjugate Solid-State Laser
We have demonstrated stable operation of a 2-kW Yb:YAG phase-conjugate master oscillator power amplifier (PC-MOPA) laser system with a loop phase-conjugate mirror (LPCM). This is the first demonstration of a continuous wave (CW)-input LPCM MOPA operating at a power greater than 1 kW with a nearly diffraction-limited output beam. The single-pass beam quality incident on the LPCM varied with the specific operating conditions, but it was typically times diffraction-limited (XDL). The measured beam quality with an MOPA output power of 1.65 kW was 1.3 XDL
Demonstration of a beam loaded nanocoulomb-class laser wakefield accelerator.
Laser-plasma wakefield accelerators have seen tremendous progress, now capable of producing quasi-monoenergetic electron beams in the GeV energy range with few-femtoseconds bunch duration. Scaling these accelerators to the nanocoulomb range would yield hundreds of kiloamperes peak current and stimulate the next generation of radiation sources covering high-field THz, high-brightness X-ray and γ-ray sources, compact free-electron lasers and laboratory-size beam-driven plasma accelerators. However, accelerators generating such currents operate in the beam loading regime where the accelerating field is strongly modified by the self-fields of the injected bunch, potentially deteriorating key beam parameters. Here we demonstrate that, if appropriately controlled, the beam loading effect can be employed to improve the accelerator's performance. Self-truncated ionization injection enables loading of unprecedented charges of ∼0.5 nC within a mono-energetic peak. As the energy balance is reached, we show that the accelerator operates at the theoretically predicted optimal loading condition and the final energy spread is minimized.Higher beam quality and stability are desired in laser-plasma accelerators for their applications in compact light sources. Here the authors demonstrate in laser plasma wakefield electron acceleration that the beam loading effect can be employed to improve beam quality by controlling the beam charge
Beam Orientation Optimization for Intensity Modulated Radiation Therapy using Adaptive l1 Minimization
Beam orientation optimization (BOO) is a key component in the process of IMRT
treatment planning. It determines to what degree one can achieve a good
treatment plan quality in the subsequent plan optimization process. In this
paper, we have developed a BOO algorithm via adaptive l_1 minimization.
Specifically, we introduce a sparsity energy function term into our model which
contains weighting factors for each beam angle adaptively adjusted during the
optimization process. Such an energy term favors small number of beam angles.
By optimizing a total energy function containing a dosimetric term and the
sparsity term, we are able to identify the unimportant beam angles and
gradually remove them without largely sacrificing the dosimetric objective. In
one typical prostate case, the convergence property of our algorithm, as well
as the how the beam angles are selected during the optimization process, is
demonstrated. Fluence map optimization (FMO) is then performed based on the
optimized beam angles. The resulted plan quality is presented and found to be
better than that obtained from unoptimized (equiangular) beam orientations. We
have further systematically validated our algorithm in the contexts of 5-9
coplanar beams for 5 prostate cases and 1 head and neck case. For each case,
the final FMO objective function value is used to compare the optimized beam
orientations and the equiangular ones. It is found that, our BOO algorithm can
lead to beam configurations which attain lower FMO objective function values
than corresponding equiangular cases, indicating the effectiveness of our BOO
algorithm.Comment: 19 pages, 2 tables, and 5 figure
Line spread instrumentation for propagation measurements
A line spread device capable of yielding direct measure of a laser beam's line spread function (LSF) was developed and employed in propagation tests conducted in a wind tunnel to examine optimal acoustical suppression techniques for laser cavities exposed to simulated aircraft aerodynamic environments. Measurements were made on various aerodynamic fences and cavity air injection techniques that effect the LSF of a propagating laser. Using the quiescent tunnel as a control, the relative effect of each technique on laser beam quality was determined. The optical instrument employed enabled the comparison of relative beam intensity for each fence or mass injection. It was found that fence height had little effect on beam quality but fence porosity had a marked effect, i.e., 58% porosity alleviated cavity resonance and degraded the beam the least. Mass injection had little effect on the beam LSF. The use of a direct LSF measuring device proved to be a viable means of determining aerodynamic seeing qualities of flow fields
- …
