3 research outputs found

    Electrocardiograph signal recognition using wavelet transform based on optimized neural network

    Get PDF
    Due to the growing number of cardiac patients, an automatic detection that detects various heart abnormalities has been developed to relieve and share physicians’ workload. Many of the depolarization of ventricles complex waves (QRS) detection algorithms with multiple properties have recently been presented; nevertheless, real-time implementations in low-cost systems remain a challenge due to limited hardware resources. The proposed algorithm finds a solution for the delay in processing by minimizing the input vector’s dimension and, as a result, the classifier’s complexity. In this paper, the wavelet transform is employed for feature extraction. The optimized neural network is used for classification with 8-classes for the electrocardiogram (ECG) signal this data is taken from two ECG signals (ST-T and MIT-BIH database). The wavelet transform coefficients are used for the artificial neural network’s training process and optimized by using the invasive weed optimization (IWO) algorithm. The suggested system has a sensitivity of over 70%, a specificity of over 94%, a positive predictive of over 65%, a negative predictive of more than 93%, and a classification accuracy of more than 80%. The performance of the classifier improves when the number of neurons in the hidden layer is increased

    Verification and comparison of MIT-BIH arrhythmia database based on number of beats

    Get PDF
    The ECG signal processing methods are tested and evaluated based on many databases. The most ECG database used for many researchers is the MIT-BIH arrhythmia database. The QRS-detection algorithms are essential for ECG analyses to detect the beats for the ECG signal. There is no standard number of beats for this database that are used from numerous researches. Different beat numbers are calculated for the researchers depending on the difference in understanding the annotation file. In this paper, the beat numbers for existing methods are studied and compared to find the correct beat number that should be used. We propose a simple function to standardize the beats number for any ECG PhysioNet database to improve the waveform database toolbox (WFDB) for the MATLAB program. This function is based on the annotation's description from the databases and can be added to the Toolbox. The function is removed the non-beats annotation without any errors. The results show a high percentage of 71% from the reviewed methods used an incorrect number of beats for this database

    Bayesian Real-Time QRS Complex Detector for Healthcare System

    No full text
    corecore