    Suppression of Second-Order Harmonic Current for Droop-Controlled Distributed Energy Resource Converters in DC Microgrids

    Get PDF
    Droop-controlled distributed energy resource converters in dc microgrids usually show low output impedances. When coupled with ac systems, second-order harmonics typically appear on the dc-bus voltage, causing significant harmonic currents at the converters resource side. This paper shows how to reduce such undesired currents by means of notch filters and resonant regulators included in the converters control loops. The main characteristics of these techniques in terms of harmonic attenuation and stability are systematically investigated. In particular, it is shown that the voltage control-loop bandwidth is limited to be below twice the line frequency to avoid instability. Then, a modified notch filter and a modified resonant regulator are proposed, allowing to remove the constraint on the voltage loop bandwidth. The resulting methods (i.e., the notch filter, the resonant regulator, and their corresponding modified versions) are evaluated in terms of output impedance and stability. Experimental results from a dc microgrid prototype composed of three dc-dc converters and one dc-ac converter, all with a rated power of 5kW, are reported

    A 300-800MHz Tunable Filter and Linearized LNA applied in a Low-Noise Harmonic-Rejection RF-Sampling Receiver

    Get PDF
    A multiband flexible RF-sampling receiver aimed at software-defined radio is presented. The wideband RF sampling function is enabled by a recently proposed discrete-time mixing downconverter. This work exploits a voltage-sensing LNA preceded by a tunable LC pre-filter with one external coil to demonstrate an RF-sampling receiver with low noise figure (NF) and high harmonic rejection (HR). The second-order LC filter provides voltage pre-gain and attenuates the source noise aliasing, and it also improves the HR ratio of the sampling downconverter. The LNA consists of a simple amplifier topology built from inverters and resistors to improve the third-order nonlinearity via an enhanced voltage mirror technique. The RF-sampling receiver employs 8 times oversampling covering 300 to 800 MHz in two RF sub-bands. The chip is realized in 65 nm CMOS and the measured gain across the band is between 22 and 28 dB, while achieving a NF between 0.8 to 4.3 dB. The IIP2 varies between +38 and +49 dBm and the IIP3 between -14 dBm and -9 dBm, and the third and fifth order HR ratios are more than 60 dB. The LNA and downconverter consumes 6 mW, and the clock generator takes 12 mW at 800 MHz RF.\ud \u

    Mitigation of DC Current Injection in Transformerless Grid-Connected Inverters

    Get PDF
    PhD ThesisWith a large number of small-scale PV plants being connected to the utility grid, there is increasing interest in the use of transformerless systems for grid-connected inverter photovoltaic applications. Compared to transformer-coupled solutions, transformerless systems offer a typical efficiency increase of 1-2%, reduced system size and weight, and reductions in cost. However, the removal of the transformer has technical implications. In addition to the loss of galvanic isolation, DC current injection into the grid is a potential risk. Whilst desirable, the complete mitigation of DC current injection via conventional current control methods is known to be particularly challenging, and there are remaining implementation issues in previous studies. For this reason, this thesis aims to minimize DC current injection in grid-connected transformerless PV inverter systems. The first part of the thesis reviews the technical challenges and implementation issues in published DC measurement techniques and suppression methods. Given mathematical models, the performance of conventional current controllers in terms of DC and harmonics mitigation is analyzed and further confirmed in simulations and experiments under different operating conditions. As a result, the second part of the thesis introduces two DC suppression methods, a DC voltage mitigation approach and a DC link current sensing technique. The former method uses a combination of a passive attenuation circuit and a software filter stage to extract the DC voltage component, which allows for further digital control and DC component mitigation at the inverter output. It is proven to be a simple and highly effective solution, applicable for any grid-connected PV inverter systems. The DC link sensing study then investigates a control-based solution in which the dc injection is firstly accurately determined via extraction of the line frequency component from the DC link current and then mitigated with a closed loop. With an output current reconstruction process, this technique provides robust current control and effective DC suppression based on DC link current measurement, eliminating the need for the conventional output current sensor. Results from rated simulation models and a laboratory grid-connected inverter system are presented to demonstrate the accurate and robust performance of the proposed techniques. This thesis makes a positive contribution in the area of power quality control in grid-connected inverters, specifically mitigating the impact of DC injection into the grid which has influences on the network operating conditions and the design and manufacture of the PV power converter itsel

    Optimization study of high power static inverters and converters Final report

    Get PDF
    Optimization study and basic performance characteristics for conceptual designs for high power static inverter

    A DC Hybrid Active Power Filter and Its Nonlinear Unified Controller Using Feedback Linearization

    Get PDF

    Development and performance of pulse-width-modulated static inverter and converter modules

    Get PDF
    Pulse-width-modulated inverter and converter modules are being developed for modular aerospace electrical power systems. The modules, rate 2.5 kilowatts per module and 10-minute - 150-percent overload, operate from 56 volts dc. The converter module provides two output voltages: a nominal link voltage of 200 volts dc when used with the inverter, and 150 volts dc to a load bus when used separately. The inverter module output is 400-hertz, sinusoidal, three-phase, 120/208 volts. Tests of breadboard models with standard parts and integrated circuits show rated power efficiencies of 71.4 and 85.1 percent and voltage regulation of 5 and 3.1 percent for inverter and converter modules, respectively. Sine-wave output distortion is 0.74 percent

    Digitally-Enhanced Software-Defined Radio Receiver Robust to Out-of-Band Interference

    Get PDF
    A software-defined radio (SDR) receiver with improved robustness to out-of-band interference (OBI) is presented. Two main challenges are identified for an OBI-robust SDR receiver: out-of-band nonlinearity and harmonic mixing. Voltage gain at RF is avoided, and instead realized at baseband in combination with low-pass filtering to mitigate blockers and improve out-of-band IIP3. Two alternative “iterative” harmonic-rejection (HR) techniques are presented to achieve high HR robust to mismatch: a) an analog two-stage polyphase HR concept, which enhances the HR to more than 60 dB; b) a digital adaptive interference cancelling (AIC) technique, which can suppress one dominating harmonic by at least 80 dB. An accurate multiphase clock generator is presented for a mismatch-robust HR. A proof-of-concept receiver is implemented in 65 nm CMOS. Measurements show 34 dB gain, 4 dB NF, and 3.5 dBm in-band IIP3 while the out-of-band IIP3 is + 16 dBm without fine tuning. The measured RF bandwidth is up to 6 GHz and the 8-phase LO works up to 0.9 GHz (master clock up to 7.2 GHz). At 0.8 GHz LO, the analog two-stage polyphase HR achieves a second to sixth order HR > dB over 40 chips, while the digital AIC technique achieves HR > 80 dB for the dominating harmonic. The total power consumption is 50 mA from a 1.2 V supply

    A Grid Voltage Feed-forward Control Strategy Based on The Virtual Impedance

    Full text link
    This paper initially investigates the conventional LCL filter grid-connected inverts system, which introduces the control strategy with inverter-side current feedback, and analyzes the deficiencies within the strategy. The stability of the controller can be improved by adopting the active damping scheme. However, the output current of the inverter is severely influenced by the external grid voltage distortion and the grid low-order harmonic voltage. In order to reduce this impact and gain high-quality power, a novel control strategy is proposed in this paper, in which the virtual complex impedance is introduced to feed grid voltage forward. By using the proposed control strategy, the total harmonic distortion can be greatly decreased, allowing the grid current to synchronize the reference current well. In addition, the modulation of the virtual complex impedance by controller can also quantificationally regulate the equivalent output impedance, which brings great convenience for inverters system designers to calculating and devising. Simulation results are presented to prove the validity and improvements achieved by the proposed controller

    Study of state-of-the-art static inverter design Final report, 6 Jan. - 6 Jun. 1966

    Get PDF
    Multiple purpose inverter design based on phase demodulated inverter circuit selected from state-of-the-art assessment of ten inverter circuit

    Beat-less algorithm based on dual-frequency compensation in railway traction applications

    Get PDF