2,443 research outputs found

    Novel modulated antennas and probes for millimeter wave imaging applications

    Get PDF
    Microwave and millimeter wave (300 MHz - 300 GHz) imaging techniques have shown great potential for a wide range of industrial and medical applications. These techniques are fundamentally based on measuring relative and coherent electromagnetic fields distributions, e.g., electric fields, around the object to be imaged. Various imaging systems can be devised for measuring relative electric field distributions; each with it own advantages and limitations. This dissertation is focused on addressing critical challenges related to the practical implementation of various microwave and millimeter wave imaging systems. Specifically, this research is meant to achieve three main objectives related to designing efficient modulated imaging methods/array elements, reducing the sensitivity to standoff distance variations in near-field imaging, and designing a simple and accurate vector network analyzer (VNA) for in-situ imaging applications. The concept of modulating millimeter wave antenna and scatterer structures, directly to increase the overall system sensitivity and reduce the image acquisition time, is central to the development presented herein. To improve upon the conventional modulated scatterer technique (MST) based on dipole scatterers; a new multiple loaded scatterer (MLS) method and novel loaded elliptical slot are introduced and analyzed. A unique near-field differential probe based on dual-loaded modulated single waveguide aperture is developed to compensate for and reduce the effect of standoff distance variations in near-field imaging. Finally, a novel vector network analyzer (VNA) design is introduced to meet the rising need for in-situ vector measuring devices. To realize a robust handheld millimeter wave VNA, a custom-designed waveguide phase shifter based on sub-resonant loaded slots is introduced. The proposed MLS method, modulated elliptical slot, dual-loaded modulated aperture probe, and VNA are thoroughly investigated and their efficacy for microwave and millimeter wave imaging is demonstrated --Abstract, page iii

    Orbital Angular Momentum Waves: Generation, Detection and Emerging Applications

    Full text link
    Orbital angular momentum (OAM) has aroused a widespread interest in many fields, especially in telecommunications due to its potential for unleashing new capacity in the severely congested spectrum of commercial communication systems. Beams carrying OAM have a helical phase front and a field strength with a singularity along the axial center, which can be used for information transmission, imaging and particle manipulation. The number of orthogonal OAM modes in a single beam is theoretically infinite and each mode is an element of a complete orthogonal basis that can be employed for multiplexing different signals, thus greatly improving the spectrum efficiency. In this paper, we comprehensively summarize and compare the methods for generation and detection of optical OAM, radio OAM and acoustic OAM. Then, we represent the applications and technical challenges of OAM in communications, including free-space optical communications, optical fiber communications, radio communications and acoustic communications. To complete our survey, we also discuss the state of art of particle manipulation and target imaging with OAM beams

    2009 Index IEEE Antennas and Wireless Propagation Letters Vol. 8

    Get PDF
    This index covers all technical items - papers, correspondence, reviews, etc. - that appeared in this periodical during the year, and items from previous years that were commented upon or corrected in this year. Departments and other items may also be covered if they have been judged to have archival value. The Author Index contains the primary entry for each item, listed under the first author\u27s name. The primary entry includes the coauthors\u27 names, the title of the paper or other item, and its location, specified by the publication abbreviation, year, month, and inclusive pagination. The Subject Index contains entries describing the item under all appropriate subject headings, plus the first author\u27s name, the publication abbreviation, month, and year, and inclusive pages. Note that the item title is found only under the primary entry in the Author Index

    2008 Index IEEE Transactions on Control Systems Technology Vol. 16

    Get PDF
    This index covers all technical items - papers, correspondence, reviews, etc. - that appeared in this periodical during the year, and items from previous years that were commented upon or corrected in this year. Departments and other items may also be covered if they have been judged to have archival value. The Author Index contains the primary entry for each item, listed under the first author\u27s name. The primary entry includes the coauthors\u27 names, the title of the paper or other item, and its location, specified by the publication abbreviation, year, month, and inclusive pagination. The Subject Index contains entries describing the item under all appropriate subject headings, plus the first author\u27s name, the publication abbreviation, month, and year, and inclusive pages. Note that the item title is found only under the primary entry in the Author Index

    Microwave and Millimeter Wave Nondestructive Testing and Evaluation -- Overview and Recent Advances

    Get PDF
    This article focuses on three recent applications of microwave and millimeter wave NDT&E techniques that involve novel instrumentation development and measurements, including: 1) disbond detection in strengthened concrete bridge members retrofitted with carbon fiber reinforced polymer (CFRP) composite laminates; 2) corrosion and precursor pitting detection in painted aluminum and steel substrates; and 3) detection of flaws in spray-on foam insulation and the acreage heat tiles of the Space Shuttle through focused and synthetic imaging techniques. These applications have been performed at the Applied Microwave Nondestructive Testing Laboratory (amntl) at the University of Missouri-Rolla

    High Resolution Near Field Microwave Imaging using Loaded Circular Aperture Probe

    Full text link
    Circular aperture probes have been successfully used for high-resolution near-field microwave imaging. It has been established that circular aperture probes could conceivably provide higher image fidelity compared to rectangular aperture probes used conventionally for near-field imaging. In this paper, it is proposed to further enhance the near-field imaging resolution and sensitivity by loading the circular aperture with a resonant iris. The proposed probe herein operates in the X-band frequency range and exhibits very localized near-field distribution at the opening of the iris. Consequently, its imaging resolution and sensitivity are enhanced compared to the conventional aperture probes operating over the same frequency band. The imaging capability of the proposed probe is analyzed using 3D electromagnetic simulation, and its performance is validated experimentally. The efficacy of the proposed probe for high-resolution imaging is demonstrated by practical imaging dielectric and metallic samples. Furthermore, the obtained images using the proposed probe are compared to those acquired using conventional circular and rectangular aperture probes. It will be demonstrated that the proposed probe provides higher sensitivity and resolution compared to the conventional aperture probes

    1-D broadside-radiating leaky-wave antenna based on a numerically synthesized impedance surface

    Get PDF
    A newly-developed deterministic numerical technique for the automated design of metasurface antennas is applied here for the first time to the design of a 1-D printed Leaky-Wave Antenna (LWA) for broadside radiation. The surface impedance synthesis process does not require any a priori knowledge on the impedance pattern, and starts from a mask constraint on the desired far-field and practical bounds on the unit cell impedance values. The designed reactance surface for broadside radiation exhibits a non conventional patterning; this highlights the merit of using an automated design process for a design well known to be challenging for analytical methods. The antenna is physically implemented with an array of metal strips with varying gap widths and simulation results show very good agreement with the predicted performance

    Beam scanning by liquid-crystal biasing in a modified SIW structure

    Get PDF
    A fixed-frequency beam-scanning 1D antenna based on Liquid Crystals (LCs) is designed for application in 2D scanning with lateral alignment. The 2D array environment imposes full decoupling of adjacent 1D antennas, which often conflicts with the LC requirement of DC biasing: the proposed design accommodates both. The LC medium is placed inside a Substrate Integrated Waveguide (SIW) modified to work as a Groove Gap Waveguide, with radiating slots etched on the upper broad wall, that radiates as a Leaky-Wave Antenna (LWA). This allows effective application of the DC bias voltage needed for tuning the LCs. At the same time, the RF field remains laterally confined, enabling the possibility to lay several antennas in parallel and achieve 2D beam scanning. The design is validated by simulation employing the actual properties of a commercial LC medium

    Thermal Monitoring: Raman Spectrometer System for Remote Measurement of Cellular Temperature on a Microscopic Scale

    Get PDF
    A simple setup was demonstrated for remote temperature monitoring of water, water-based media, and cells on a microscopic scale. The technique relies on recording changes in the shape of a stretching band of the hydroxyl group in liquid water at 3,100-3,700 cm^(-1). Rather than direct measurements in the near-infrared (IR), a simple Raman spectrometer setup was realized. The measured Raman shifts were observed at near optical wavelengths using an inverted microscope with standard objectives in contrast to costly near-IR elements. This allowed for simultaneous visible inspection through the same optical path. An inexpensive 671-nm diode pump laser (<100 mW), standard dichroic and lowpass filters, and a commercial 600-1,000 nm spectrometer complete the instrument
    • …
    corecore