274 research outputs found

    Restoring Fine Motor Skills through Neural Interface Technology.

    Full text link
    Loss of motor function in the upper-limb, whether through paralysis or through loss of the limb itself, is a profound disability which affects a large population worldwide. Lifelike, fully-articulated prosthetic hands exist and are commercially available; however, there is currently no satisfactory method of controlling all of the available degrees of freedom. In order to generate better control signals for this technology, and help restore normal movement, it is necessary to interface directly with the nervous system. This thesis is intended to address several of the limitations of current neural interfaces and enable the long-term extraction of control signals for fine movements of the hand and fingers. The first study addresses the problems of low signal amplitudes and short implant lifetimes in peripheral nerve interfaces. In two rhesus macaques, we demonstrate the successful implantation of regenerative peripheral nerve interfaces (RPNI), which allowed us to record high amplitude, functionally-selective signals from peripheral nerves up to 20 months post-implantation. These signals could be accurately decoded into intended movement, and used to enable monkeys to control a virtual hand prosthesis. The second study presents a novel experimental paradigm for intracortical neural interfaces, which enables detailed investigation of fine motor information contained in primary motor cortex. We used this paradigm to demonstrate accurate decoding of continuous fingertip position and enable a monkey to control a virtual hand in closed-loop. This is the first demonstration of volitional control of fine motor skill enabled by a cortical neural interface. The final study presents the design and testing of a wireless implantable neural recording system. By extracting signal power in a single, configurable frequency band onboard the device, this system achieves low power consumption while maintaining decode performance, and is applicable to cortical, peripheral, and myoelectric signals. Taken together, these results represent a significant step towards clinical reality for neural interfaces, and towards restoration of full and dexterous movement for people with severe disabilities.PhDBiomedical EngineeringUniversity of Michigan, Horace H. Rackham School of Graduate Studieshttp://deepblue.lib.umich.edu/bitstream/2027.42/120648/1/irwinz_1.pd

    Microwire regenerative peripheral nerve interfaces with wireless recording and stimulation capabilities

    Get PDF
    A scalable microwire peripheral nerve interface was developed, which interacted with regenerated peripheral nerves in microchannel scaffolds. Neural interface technologies are envisioned to facilitate direct connections between the nervous system and external technologies such as limb prosthetics or data acquisition systems for further processing. Presented here is an animal study using a handcrafted microwire regenerative peripheral nerve interface, a novel neural interface device for communicating with peripheral nerves. The neural interface studies using animal models are crucial in the evaluation of efficacy and safety of implantable medical devices before their use in clinical studies.16-electrode microwire microchannel scaffolds were developed for both peripheral nerve regeneration and peripheral nerve interfacing. The microchannels were used for nerve regeneration pathways as a scaffolding material and the embedded microwires were used as a recording electrode to capture neural signals from the regenerated peripheral nerves. Wireless stimulation and recording capabilities were also incorporated to the developed peripheral nerve interface which gave the freedom of the complex experimental setting of wired data acquisition systems and minimized the potential infection of the animals from the wire connections

    Biointegrated and wirelessly powered implantable brain devices: a review

    Get PDF
    Implantable neural interfacing devices have added significantly to neural engineering by introducing the low-frequency oscillations of small populations of neurons known as local field potential as well as high-frequency action potentials of individual neurons. Regardless of the astounding progression as of late, conventional neural modulating system is still incapable to achieve the desired chronic in vivo implantation. The real constraint emerges from mechanical and physical diffierences between implants and brain tissue that initiates an inflammatory reaction and glial scar formation that reduces the recording and stimulation quality. Furthermore, traditional strategies consisting of rigid and tethered neural devices cause substantial tissue damage and impede the natural behaviour of an animal, thus hindering chronic in vivo measurements. Therefore, enabling fully implantable neural devices, requires biocompatibility, wireless power/data capability, biointegration using thin and flexible electronics, and chronic recording properties. This paper reviews biocompatibility and design approaches for developing biointegrated and wirelessly powered implantable neural devices in animals aimed at long-term neural interfacing and outlines current challenges toward developing the next generation of implantable neural devices

    The future of upper extremity rehabilitation robotics: research and practice

    Full text link
    The loss of upper limb motor function can have a devastating effect on peopleโ€™s lives. To restore upper limb control and functionality, researchers and clinicians have developed interfaces to interact directly with the human bodyโ€™s motor system. In this invited review, we aim to provide details on the peripheral nerve interfaces and brainโ€machine interfaces that have been developed in the past 30โ€‰years for upper extremity control, and we highlight the challenges that still remain to transition the technology into the clinical market. The findings show that peripheral nerve interfaces and brainโ€machine interfaces have many similar characteristics that enable them to be concurrently developed. Decoding neural information from both interfaces may lead to novel physiological models that may one day fully restore upper limb motor function for a growing patient population.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/155489/1/mus26860_am.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/155489/2/mus26860.pd

    Towards Natural Control of Artificial Limbs

    Get PDF
    The use of implantable electrodes has been long thought as the solution for a more natural control of artificial limbs, as these offer access to long-term stable and physiologically appropriate sources of control, as well as the possibility to elicit appropriate sensory feedback via neurostimulation. Although these ideas have been explored since the 1960โ€™s, the lack of a long-term stable human-machine interface has prevented the utilization of even the simplest implanted electrodes in clinically viable limb prostheses.In this thesis, a novel human-machine interface for bidirectional communication between implanted electrodes and the artificial limb was developed and clinically implemented. The long-term stability was achieved via osseointegration, which has been shown to provide stable skeletal attachment. By enhancing this technology as a communication gateway, the longest clinical implementation of prosthetic control sourced by implanted electrodes has been achieved, as well as the first in modern times. The first recipient has used it uninterruptedly in daily and professional activities for over one year. Prosthetic control was found to improve in resolution while requiring less muscular effort, as well as to be resilient to motion artifacts, limb position, and environmental conditions.In order to support this work, the literature was reviewed in search of reliable and safe neuromuscular electrodes that could be immediately used in humans. Additional work was conducted to improve the signal-to-noise ratio and increase the amount of information retrievable from extraneural recordings. Different signal processing and pattern recognition algorithms were investigated and further developed towards real-time and simultaneous prediction of limb movements. These algorithms were used to demonstrate that higher functionality could be restored by intuitive control of distal joints, and that such control remains viable over time when using epimysial electrodes. Lastly, the long-term viability of direct nerve stimulation to produce intuitive sensory feedback was also demonstrated.The possibility to permanently and reliably access implanted electrodes, thus making them viable for prosthetic control, is potentially the main contribution of this work. Furthermore, the opportunity to chronically record and stimulate the neuromuscular system offers new venues for the prediction of complex limb motions and increased understanding of somatosensory perception. Therefore, the technology developed here, combining stable attachment with permanent and reliable human-machine communication, is considered by the author as a critical step towards more functional artificial limbs

    The Use of Skeletal Muscle to Amplify Action Potentials in Transected Peripheral Nerves

    Get PDF
    Upper limb amputees suffer with problems associated with control and attachment of prostheses. Skin-surface electrodes placed over the stump, which detect myoelectric signals, are traditionally used to control hand movements. However, this method is unintuitive, the electrodes lift-off, and signal selectivity can be an issue. One solution to these limitations is to implant electrodes directly on muscles. Another approach is to implant electrodes directly into the nerves that innervate the muscles. A significant challenge with both solutions is the reliable transmission of biosignals across the skin barrier. In this thesis, I investigated the use of implantable muscle electrodes in an ovine model using myoelectrodes in combination with a bone-anchor, acting as a conduit for signal transmission. High-quality readings were obtained which were significantly better than skin-surface electrode readings. I further investigated the effect of electrode configurations to achieve the best signal quality. For direct recording from nerves, I tested the effect of adsorbed endoneural basement membrane proteins on nerve regeneration in vivo using microchannel neural interfaces implanted in rat sciatic nerves. Muscle and nerve signal recordings were obtained and improvements in sciatic nerve function were observed. Direct skeletal fixation of a prosthesis to the amputation stump using a bone-anchor has been proposed as a solution to skin problems associated with traditional socket-type prostheses. However, there remains a concern about the risk of infection between the implant and skin. Achieving a durable seal at this interface is therefore crucial, which formed the final part of the thesis. Bone-anchors were optimised for surface pore size and coatings to facilitate binding of human dermal fibroblasts to optimise skin-implant seal in an ovine model. Implants silanised with Arginine-Glycine-Aspartic Acid experienced significantly increased dermal tissue infiltration. This approach may therefore improve the soft tissue seal, and thus success of bone-anchored implants. By addressing both the way prostheses are attached to the amputation stump, by way of direct skeletal fixation, as well as providing high fidelity biosignals for high-level intuitive prosthetic control, I aim to further the field of limb loss rehabilitation

    Improving the mechanistic study of neuromuscular diseases through the development of a fully wireless and implantable recording device

    Get PDF
    Neuromuscular diseases manifest by a handful of known phenotypes affecting the peripheral nerves, skeletal muscle fibers, and neuromuscular junction. Common signs of these diseases include demyelination, myasthenia, atrophy, and aberrant muscle activityโ€”all of which may be tracked over time using one or more electrophysiological markers. Mice, which are the predominant mammalian model for most human diseases, have been used to study congenital neuromuscular diseases for decades. However, our understanding of the mechanisms underlying these pathologies is still incomplete. This is in part due to the lack of instrumentation available to easily collect longitudinal, in vivo electrophysiological activity from mice. There remains a need for a fully wireless, batteryless, and implantable recording system that can be adapted for a variety of electrophysiological measurements and also enable long-term, continuous data collection in very small animals. To meet this need a miniature, chronically implantable device has been developed that is capable of wirelessly coupling energy from electromagnetic fields while implanted within a body. This device can both record and trigger bioelectric events and may be chronically implanted in rodents as small as mice. This grants investigators the ability to continuously observe electrophysiological changes corresponding to disease progression in a single, freely behaving, untethered animal. The fully wireless closed-loop system is an adaptable solution for a range of long-term mechanistic and diagnostic studies in rodent disease models. Its high level of functionality, adjustable parameters, accessible building blocks, reprogrammable firmware, and modular electrode interface offer flexibility that is distinctive among fully implantable recording or stimulating devices. The key significance of this work is that it has generated novel instrumentation in the form of a fully implantable bioelectric recording device having a much higher level of functionality than any other fully wireless system available for mouse work. This has incidentally led to contributions in the areas of wireless power transfer and neural interfaces for upper-limb prosthesis control. Herein the solution space for wireless power transfer is examined including a close inspection of far-field power transfer to implanted bioelectric sensors. Methods of design and characterization for the iterative development of the device are detailed. Furthermore, its performance and utility in remote bioelectric sensing applications is demonstrated with humans, rats, healthy mice, and mouse models for degenerative neuromuscular and motoneuron diseases

    ์†Œํ˜•๋™๋ฌผ์˜ ๋‡Œ์‹ ๊ฒฝ ์ž๊ทน์„ ์œ„ํ•œ ์™„์ „ ์ด์‹ํ˜• ์‹ ๊ฒฝ์ž๊ทน๊ธฐ

    Get PDF
    ํ•™์œ„๋…ผ๋ฌธ(๋ฐ•์‚ฌ)--์„œ์šธ๋Œ€ํ•™๊ต ๋Œ€ํ•™์› :๊ณต๊ณผ๋Œ€ํ•™ ์ „๊ธฐยท์ •๋ณด๊ณตํ•™๋ถ€,2020. 2. ๊น€์„ฑ์ค€.In this study, a fully implantable neural stimulator that is designed to stimulate the brain in the small animal is described. Electrical stimulation of the small animal is applicable to pre-clinical study, and behavior study for neuroscience research, etc. Especially, behavior study of the freely moving animal is useful to observe the modulation of sensory and motor functions by the stimulation. It involves conditioning animal's movement response through directional neural stimulation on the region of interest. The main technique that enables such applications is the development of an implantable neural stimulator. Implantable neural stimulator is used to modulate the behavior of the animal, while it ensures the free movement of the animals. Therefore, stable operation in vivo and device size are important issues in the design of implantable neural stimulators. Conventional neural stimulators for brain stimulation of small animal are comprised of electrodes implanted in the brain and a pulse generation circuit mounted on the back of the animal. The electrical stimulation generated from the circuit is conveyed to the target region by the electrodes wire-connected with the circuit. The devices are powered by a large battery, and controlled by a microcontroller unit. While it represents a simple approach, it is subject to various potential risks including short operation time, infection at the wound, mechanical failure of the device, and animals being hindered to move naturally, etc. A neural stimulator that is miniaturized, fully implantable, low-powered, and capable of wireless communication is required. In this dissertation, a fully implantable stimulator with remote controllability, compact size, and minimal power consumption is suggested for freely moving animal application. The stimulator consists of modular units of surface-type and depth-type arrays for accessing target brain area, package for accommodating the stimulating electronics all of which are assembled after independent fabrication and implantation using customized flat cables and connectors. The electronics in the package contains ZigBee telemetry for low-power wireless communication, inductive link for recharging lithium battery, and an ASIC that generates biphasic pulse for neural stimulation. A dual-mode power-saving scheme with a duty cycling was applied to minimize the power consumption. All modules were packaged using liquid crystal polymer (LCP) to avoid any chemical reaction after implantation. To evaluate the fabricated stimulator, wireless operation test was conducted. Signal-to-Noise Ratio (SNR) of the ZigBee telemetry were measured, and its communication range and data streaming capacity were tested. The amount of power delivered during the charging session depending on the coil distance was measured. After the evaluation of the device functionality, the stimulator was implanted into rats to train the animals to turn to the left (or right) following a directional cue applied to the barrel cortex. Functionality of the device was also demonstrated in a three-dimensional maze structure, by guiding the rats to navigate better in the maze. Finally, several aspects of the fabricated device were discussed further.๋ณธ ์—ฐ๊ตฌ์—์„œ๋Š” ์†Œํ˜• ๋™๋ฌผ์˜ ๋‘๋‡Œ๋ฅผ ์ž๊ทนํ•˜๊ธฐ ์œ„ํ•œ ์™„์ „ ์ด์‹ํ˜• ์‹ ๊ฒฝ์ž๊ทน๊ธฐ๊ฐ€ ๊ฐœ๋ฐœ๋˜์—ˆ๋‹ค. ์†Œํ˜• ๋™๋ฌผ์˜ ์ „๊ธฐ์ž๊ทน์€ ์ „์ž„์ƒ ์—ฐ๊ตฌ, ์‹ ๊ฒฝ๊ณผํ•™ ์—ฐ๊ตฌ๋ฅผ ์œ„ํ•œ ํ–‰๋™์—ฐ๊ตฌ ๋“ฑ์— ํ™œ์šฉ๋œ๋‹ค. ํŠนํžˆ, ์ž์œ ๋กญ๊ฒŒ ์›€์ง์ด๋Š” ๋™๋ฌผ์„ ๋Œ€์ƒ์œผ๋กœ ํ•œ ํ–‰๋™ ์—ฐ๊ตฌ๋Š” ์ž๊ทน์— ์˜ํ•œ ๊ฐ๊ฐ ๋ฐ ์šด๋™ ๊ธฐ๋Šฅ์˜ ์กฐ์ ˆ์„ ๊ด€์ฐฐํ•˜๋Š” ๋ฐ ์œ ์šฉํ•˜๊ฒŒ ํ™œ์šฉ๋œ๋‹ค. ํ–‰๋™ ์—ฐ๊ตฌ๋Š” ๋‘๋‡Œ์˜ ํŠน์ • ๊ด€์‹ฌ ์˜์—ญ์„ ์ง์ ‘์ ์œผ๋กœ ์ž๊ทนํ•˜์—ฌ ๋™๋ฌผ์˜ ํ–‰๋™๋ฐ˜์‘์„ ์กฐ๊ฑดํ™”ํ•˜๋Š” ๋ฐฉ์‹์œผ๋กœ ์ˆ˜ํ–‰๋œ๋‹ค. ์ด๋Ÿฌํ•œ ์ ์šฉ์„ ๊ฐ€๋Šฅ์ผ€ ํ•˜๋Š” ํ•ต์‹ฌ๊ธฐ์ˆ ์€ ์ด์‹ํ˜• ์‹ ๊ฒฝ์ž๊ทน๊ธฐ์˜ ๊ฐœ๋ฐœ์ด๋‹ค. ์ด์‹ํ˜• ์‹ ๊ฒฝ์ž๊ทน๊ธฐ๋Š” ๋™๋ฌผ์˜ ์›€์ง์ž„์„ ๋ฐฉํ•ดํ•˜์ง€ ์•Š์œผ๋ฉด์„œ๋„ ๊ทธ ํ–‰๋™์„ ์กฐ์ ˆํ•˜๊ธฐ ์œ„ํ•ด ์‚ฌ์šฉ๋œ๋‹ค. ๋”ฐ๋ผ์„œ ๋™๋ฌผ ๋‚ด์—์„œ์˜ ์•ˆ์ •์ ์ธ ๋™์ž‘๊ณผ ์žฅ์น˜์˜ ํฌ๊ธฐ๊ฐ€ ์ด์‹ํ˜• ์‹ ๊ฒฝ์ž๊ทน๊ธฐ๋ฅผ ์„ค๊ณ„ํ•จ์— ์žˆ์–ด ์ค‘์š”ํ•œ ๋ฌธ์ œ์ด๋‹ค. ๊ธฐ์กด์˜ ์‹ ๊ฒฝ์ž๊ทน๊ธฐ๋Š” ๋‘๋‡Œ์— ์ด์‹๋˜๋Š” ์ „๊ทน ๋ถ€๋ถ„๊ณผ, ๋™๋ฌผ์˜ ๋“ฑ ๋ถ€๋ถ„์— ์œ„์น˜ํ•œ ํšŒ๋กœ๋ถ€๋ถ„์œผ๋กœ ๊ตฌ์„ฑ๋œ๋‹ค. ํšŒ๋กœ์—์„œ ์ƒ์‚ฐ๋œ ์ „๊ธฐ์ž๊ทน์€ ํšŒ๋กœ์™€ ์ „์„ ์œผ๋กœ ์—ฐ๊ฒฐ๋œ ์ „๊ทน์„ ํ†ตํ•ด ๋ชฉํ‘œ ์ง€์ ์œผ๋กœ ์ „๋‹ฌ๋œ๋‹ค. ์žฅ์น˜๋Š” ๋ฐฐํ„ฐ๋ฆฌ์— ์˜ํ•ด ๊ตฌ๋™๋˜๋ฉฐ, ๋‚ด์žฅ๋œ ๋งˆ์ดํฌ๋กœ ์ปจํŠธ๋กค๋Ÿฌ์— ์˜ํ•ด ์ œ์–ด๋œ๋‹ค. ์ด๋Š” ์‰ฝ๊ณ  ๊ฐ„๋‹จํ•œ ์ ‘๊ทผ๋ฐฉ์‹์ด์ง€๋งŒ, ์งง์€ ๋™์ž‘์‹œ๊ฐ„, ์ด์‹๋ถ€์œ„์˜ ๊ฐ์—ผ์ด๋‚˜ ์žฅ์น˜์˜ ๊ธฐ๊ณ„์  ๊ฒฐํ•จ, ๊ทธ๋ฆฌ๊ณ  ๋™๋ฌผ์˜ ์ž์—ฐ์Šค๋Ÿฌ์šด ์›€์ง์ž„ ๋ฐฉํ•ด ๋“ฑ ์—ฌ๋Ÿฌ ๋ฌธ์ œ์ ์„ ์•ผ๊ธฐํ•  ์ˆ˜ ์žˆ๋‹ค. ์ด๋Ÿฌํ•œ ๋ฌธ์ œ์˜ ๊ฐœ์„ ์„ ์œ„ํ•ด ๋ฌด์„ ํ†ต์‹ ์ด ๊ฐ€๋Šฅํ•˜๊ณ , ์ €์ „๋ ฅ, ์†Œํ˜•ํ™”๋œ ์™„์ „ ์ด์‹ํ˜• ์‹ ๊ฒฝ์ž๊ทน๊ธฐ์˜ ์„ค๊ณ„๊ฐ€ ํ•„์š”ํ•˜๋‹ค. ๋ณธ ์—ฐ๊ตฌ์—์„œ๋Š” ์ž์œ ๋กญ๊ฒŒ ์›€์ง์ด๋Š” ๋™๋ฌผ์— ์ ์šฉํ•˜๊ธฐ ์œ„ํ•˜์—ฌ ์›๊ฒฉ ์ œ์–ด๊ฐ€ ๊ฐ€๋Šฅํ•˜๋ฉฐ, ํฌ๊ธฐ๊ฐ€ ์ž‘๊ณ , ์†Œ๋ชจ์ „๋ ฅ์ด ์ตœ์†Œํ™”๋œ ์™„์ „์ด์‹ํ˜• ์ž๊ทน๊ธฐ๋ฅผ ์ œ์‹œํ•œ๋‹ค. ์„ค๊ณ„๋œ ์‹ ๊ฒฝ์ž๊ทน๊ธฐ๋Š” ๋ชฉํ‘œ๋กœ ํ•˜๋Š” ๋‘๋‡Œ ์˜์—ญ์— ์ ‘๊ทผํ•  ์ˆ˜ ์žˆ๋Š” ํ‘œ๋ฉดํ˜• ์ „๊ทน๊ณผ ํƒ์นจํ˜• ์ „๊ทน, ๊ทธ๋ฆฌ๊ณ  ์ž๊ทน ํŽ„์Šค ์ƒ์„ฑ ํšŒ๋กœ๋ฅผ ํฌํ•จํ•˜๋Š” ํŒจํ‚ค์ง€ ๋“ฑ์˜ ๋ชจ๋“ˆ๋“ค๋กœ ๊ตฌ์„ฑ๋˜๋ฉฐ, ๊ฐ๊ฐ์˜ ๋ชจ๋“ˆ์€ ๋…๋ฆฝ์ ์œผ๋กœ ์ œ์ž‘๋˜์–ด ๋™๋ฌผ์— ์ด์‹๋œ ๋’ค ์ผ€์ด๋ธ”๊ณผ ์ปค๋„ฅํ„ฐ๋กœ ์—ฐ๊ฒฐ๋œ๋‹ค. ํŒจํ‚ค์ง€ ๋‚ด๋ถ€์˜ ํšŒ๋กœ๋Š” ์ €์ „๋ ฅ ๋ฌด์„ ํ†ต์‹ ์„ ์œ„ํ•œ ์ง€๊ทธ๋น„ ํŠธ๋žœ์‹œ๋ฒ„, ๋ฆฌํŠฌ ๋ฐฐํ„ฐ๋ฆฌ์˜ ์žฌ์ถฉ์ „์„ ์œ„ํ•œ ์ธ๋•ํ‹ฐ๋ธŒ ๋งํฌ, ๊ทธ๋ฆฌ๊ณ  ์‹ ๊ฒฝ์ž๊ทน์„ ์œ„ํ•œ ์ด์ƒ์„ฑ ์ž๊ทนํŒŒํ˜•์„ ์ƒ์„ฑํ•˜๋Š” ASIC์œผ๋กœ ๊ตฌ์„ฑ๋œ๋‹ค. ์ „๋ ฅ ์ ˆ๊ฐ์„ ์œ„ํ•ด ๋‘ ๊ฐœ์˜ ๋ชจ๋“œ๋ฅผ ํ†ตํ•ด ์‚ฌ์šฉ๋ฅ ์„ ์กฐ์ ˆํ•˜๋Š” ๋ฐฉ์‹์ด ์žฅ์น˜์— ์ ์šฉ๋œ๋‹ค. ๋ชจ๋“  ๋ชจ๋“ˆ๋“ค์€ ์ด์‹ ํ›„์˜ ์ƒ๋ฌผํ•™์ , ํ™”ํ•™์  ์•ˆ์ •์„ฑ์„ ์œ„ํ•ด ์•ก์ • ํด๋ฆฌ๋จธ๋กœ ํŒจํ‚ค์ง•๋˜์—ˆ๋‹ค. ์ œ์ž‘๋œ ์‹ ๊ฒฝ์ž๊ทน๊ธฐ๋ฅผ ํ‰๊ฐ€ํ•˜๊ธฐ ์œ„ํ•ด ๋ฌด์„  ๋™์ž‘ ํ…Œ์ŠคํŠธ๊ฐ€ ์ˆ˜ํ–‰๋˜์—ˆ๋‹ค. ์ง€๊ทธ๋น„ ํ†ต์‹ ์˜ ์‹ ํ˜ธ ๋Œ€ ์žก์Œ๋น„๊ฐ€ ์ธก์ •๋˜์—ˆ์œผ๋ฉฐ, ํ•ด๋‹น ํ†ต์‹ ์˜ ๋™์ž‘๊ฑฐ๋ฆฌ ๋ฐ ๋ฐ์ดํ„ฐ ์ŠคํŠธ๋ฆฌ๋ฐ ์„ฑ๋Šฅ์ด ๊ฒ€์‚ฌ๋˜์—ˆ๊ณ , ์žฅ์น˜์˜ ์ถฉ์ „์ด ์ˆ˜ํ–‰๋  ๋•Œ ์ฝ”์ผ๊ฐ„์˜ ๊ฑฐ๋ฆฌ์— ๋”ฐ๋ผ ์ „์†ก๋˜๋Š” ์ „๋ ฅ์˜ ํฌ๊ธฐ๊ฐ€ ์ธก์ •๋˜์—ˆ๋‹ค. ์žฅ์น˜์˜ ํ‰๊ฐ€ ์ดํ›„, ์‹ ๊ฒฝ์ž๊ทน๊ธฐ๋Š” ์ฅ์— ์ด์‹๋˜์—ˆ์œผ๋ฉฐ, ํ•ด๋‹น ๋™๋ฌผ์€ ์ด์‹๋œ ์žฅ์น˜๋ฅผ ์ด์šฉํ•ด ๋ฐฉํ–ฅ ์‹ ํ˜ธ์— ๋”ฐ๋ผ ์ขŒ์šฐ๋กœ ์ด๋™ํ•˜๋„๋ก ํ›ˆ๋ จ๋˜์—ˆ๋‹ค. ๋˜ํ•œ, 3์ฐจ์› ๋ฏธ๋กœ ๊ตฌ์กฐ์—์„œ ์ฅ์˜ ์ด๋™๋ฐฉํ–ฅ์„ ์œ ๋„ํ•˜๋Š” ์‹คํ—˜์„ ํ†ตํ•˜์—ฌ ์žฅ์น˜์˜ ๊ธฐ๋Šฅ์„ฑ์„ ์ถ”๊ฐ€์ ์œผ๋กœ ๊ฒ€์ฆํ•˜์˜€๋‹ค. ๋งˆ์ง€๋ง‰์œผ๋กœ, ์ œ์ž‘๋œ ์žฅ์น˜์˜ ํŠน์ง•์ด ์—ฌ๋Ÿฌ ์ธก๋ฉด์—์„œ ์‹ฌ์ธต์ ์œผ๋กœ ๋…ผ์˜๋˜์—ˆ๋‹ค.Chapter 1 : Introduction 1 1.1. Neural Interface 2 1.1.1. Concept 2 1.1.2. Major Approaches 3 1.2. Neural Stimulator for Animal Brain Stimulation 5 1.2.1. Concept 5 1.2.2. Neural Stimulator for Freely Moving Small Animal 7 1.3. Suggested Approaches 8 1.3.1. Wireless Communication 8 1.3.2. Power Management 9 1.3.2.1. Wireless Power Transmission 10 1.3.2.2. Energy Harvesting 11 1.3.3. Full implantation 14 1.3.3.1. Polymer Packaging 14 1.3.3.2. Modular Configuration 16 1.4. Objectives of This Dissertation 16 Chapter 2 : Methods 18 2.1. Overview 19 2.1.1. Circuit Description 20 2.1.1.1. Pulse Generator ASIC 21 2.1.1.2. ZigBee Transceiver 23 2.1.1.3. Inductive Link 24 2.1.1.4. Energy Harvester 25 2.1.1.5. Surrounding Circuitries 26 2.1.2. Software Description 27 2.2. Antenna Design 29 2.2.1. RF Antenna 30 2.2.1.1. Design of Monopole Antenna 31 2.2.1.2. FEM Simulation 31 2.2.2. Inductive Link 36 2.2.2.1. Design of Coil Antenna 36 2.2.2.2. FEM Simulation 38 2.3. Device Fabrication 41 2.3.1. Circuit Assembly 41 2.3.2. Packaging 42 2.3.3. Electrode, Feedthrough, Cable, and Connector 43 2.4. Evaluations 45 2.4.1. Wireless Operation Test 46 2.4.1.1. Signal-to-Noise Ratio (SNR) Measurement 46 2.4.1.2. Communication Range Test 47 2.4.1.3. Device Operation Monitoring Test 48 2.4.2. Wireless Power Transmission 49 2.4.3. Electrochemical Measurements In Vitro 50 2.4.4. Animal Testing In Vivo 52 Chapter 3 : Results 57 3.1. Fabricated System 58 3.2. Wireless Operation Test 59 3.2.1. Signal-to-Noise Ratio Measurement 59 3.2.2. Communication Range Test 61 3.2.3. Device Operation Monitoring Test 62 3.3. Wireless Power Transmission 64 3.4. Electrochemical Measurements In Vitro 65 3.5. Animal Testing In Vivo 67 Chapter 4 : Discussion 73 4.1. Comparison with Conventional Devices 74 4.2. Safety of Device Operation 76 4.2.1. Safe Electrical Stimulation 76 4.2.2. Safe Wireless Power Transmission 80 4.3. Potential Applications 84 4.4. Opportunities for Further Improvements 86 4.4.1. Weight and Size 86 4.4.2. Long-Term Reliability 93 Chapter 5 : Conclusion 96 Reference 98 Appendix - Liquid Crystal Polymer (LCP) -Based Spinal Cord Stimulator 107 ๊ตญ๋ฌธ ์ดˆ๋ก 138 ๊ฐ์‚ฌ์˜ ๊ธ€ 140Docto

    A Versatile Hermetically Sealed Microelectronic Implant for Peripheral Nerve Stimulation Applications

    Get PDF
    This article presents a versatile neurostimulation platform featuring a fully implantable multi-channel neural stimulator for chronic experimental studies with freely moving large animal models involving peripheral nerves. The implant is hermetically sealed in a ceramic enclosure and encapsulated in medical grade silicone rubber, and then underwent active tests at accelerated aging conditions at 100ยฐC for 15 consecutive days. The stimulator microelectronics are implemented in a 0.6-ฮผm CMOS technology, with a crosstalk reduction scheme to minimize cross-channel interference, and high-speed power and data telemetry for battery-less operation. A wearable transmitter equipped with a Bluetooth Low Energy radio link, and a custom graphical user interface provide real-time, remotely controlled stimulation. Three parallel stimulators provide independent stimulation on three channels, where each stimulator supports six stimulating sites and two return sites through multiplexing, hence the implant can facilitate stimulation at up to 36 different electrode pairs. The design of the electronics, method of hermetic packaging and electrical performance as well as in vitro testing with electrodes in saline are presented
    • โ€ฆ
    corecore