1,612 research outputs found
Thyroid Segmentation and Volume Estimation Using CT Images
ABSTRACT: Pathology of thyroid gland is determined by physicians with its volume as a significant indicator.For this thyroid area segmentation and volume estimation are necessary steps. Most physicians use CT images even if the volume of thyroid gland is determined using Ultrasound images, for precise evaluation of volume of thyroid gland. In this paper a Linear Vector Quantization neural network (LVQNN) with a pre-processing procedure and initial segmentation using cellular automata(CA) is proposed for thyroid segmentation and volume estimation using computerized tomography (CT) images
Tracked 3D ultrasound and deep neural network-based thyroid segmentation reduce interobserver variability in thyroid volumetry
Thyroid volumetry is crucial in the diagnosis, treatment, and monitoring of thyroid diseases. However, conventional thyroid volumetry with 2D ultrasound is highly operator-dependent. This study compares 2D and tracked 3D ultrasound with an automatic thyroid segmentation based on a deep neural network regarding inter- and intraobserver variability, time, and accuracy. Volume reference was MRI. 28 healthy volunteers (24—50 a) were scanned with 2D and 3D ultrasound (and by MRI) by three physicians (MD 1, 2, 3) with different experience levels (6, 4, and 1 a). In the 2D scans, the thyroid lobe volumes were calculated with the ellipsoid formula. A convolutional deep neural network (CNN) automatically segmented the 3D thyroid lobes. 26, 6, and 6 random lobe scans were used for training, validation, and testing, respectively. On MRI (T1 VIBE sequence) the thyroid was manually segmented by an experienced MD. MRI thyroid volumes ranged from 2.8 to 16.7ml (mean 7.4, SD 3.05). The CNN was trained to obtain an average Dice score of 0.94. The interobserver variability comparing two MDs showed mean differences for 2D and 3D respectively of 0.58 to 0.52ml (MD1 vs. 2), −1.33 to −0.17ml (MD1 vs. 3) and −1.89 to −0.70ml (MD2 vs. 3). Paired samples t-tests showed significant differences for 2D (p = .140, p = .002 and p = .002) and none for 3D (p = .176, p = .722 and p = .057). Intraobsever variability was similar for 2D and 3D ultrasound. Comparison of ultrasound volumes and MRI volumes showed a significant difference for the 2D volumetry of all MDs (p = .002, p = .009, p <.001), and no significant difference for 3D ultrasound (p = .292, p = .686, p = 0.091). Acquisition time was significantly shorter for 3D ultrasound. Tracked 3D ultrasound combined with a CNN segmentation significantly reduces interobserver variability in thyroid volumetry and increases the accuracy of the measurements with shorter acquisition times
A Survey on Deep Learning in Medical Image Analysis
Deep learning algorithms, in particular convolutional networks, have rapidly
become a methodology of choice for analyzing medical images. This paper reviews
the major deep learning concepts pertinent to medical image analysis and
summarizes over 300 contributions to the field, most of which appeared in the
last year. We survey the use of deep learning for image classification, object
detection, segmentation, registration, and other tasks and provide concise
overviews of studies per application area. Open challenges and directions for
future research are discussed.Comment: Revised survey includes expanded discussion section and reworked
introductory section on common deep architectures. Added missed papers from
before Feb 1st 201
Recent Advances in Machine Learning Applied to Ultrasound Imaging
Machine learning (ML) methods are pervading an increasing number of fields of application because of their capacity to effectively solve a wide variety of challenging problems. The employment of ML techniques in ultrasound imaging applications started several years ago but the scientific interest in this issue has increased exponentially in the last few years. The present work reviews the most recent (2019 onwards) implementations of machine learning techniques for two of the most popular ultrasound imaging fields, medical diagnostics and non-destructive evaluation. The former, which covers the major part of the review, was analyzed by classifying studies according to the human organ investigated and the methodology (e.g., detection, segmentation, and/or classification) adopted, while for the latter, some solutions to the detection/classification of material defects or particular patterns are reported. Finally, the main merits of machine learning that emerged from the study analysis are summarized and discussed. © 2022 by the authors. Licensee MDPI, Basel, Switzerland
Machine Learning in Robotic Ultrasound Imaging: Challenges and Perspectives
This article reviews the recent advances in intelligent robotic ultrasound
(US) imaging systems. We commence by presenting the commonly employed robotic
mechanisms and control techniques in robotic US imaging, along with their
clinical applications. Subsequently, we focus on the deployment of machine
learning techniques in the development of robotic sonographers, emphasizing
crucial developments aimed at enhancing the intelligence of these systems. The
methods for achieving autonomous action reasoning are categorized into two sets
of approaches: those relying on implicit environmental data interpretation and
those using explicit interpretation. Throughout this exploration, we also
discuss practical challenges, including those related to the scarcity of
medical data, the need for a deeper understanding of the physical aspects
involved, and effective data representation approaches. Moreover, we conclude
by highlighting the open problems in the field and analyzing different possible
perspectives on how the community could move forward in this research area.Comment: Accepted by Annual Review of Control, Robotics, and Autonomous