International audienceThe Jiangmen Underground Neutrino Observatory (JUNO) in southern China is designed to study neutrinos from nuclear reactors and natural sources to address fundamental questions in neutrino physics. Achieving its goals requires continuous operation over a 20-year period. The small photomultiplier tube (small PMT or SPMT) system is a subsystem within the experiment composed of 25600 3-inch PMTs and their associated readout electronics. The High Voltage Splitter (HVS) is the first board on the readout chain of the SPMT system and services the PMTs by providing high voltage for biasing and by decoupling the generated physics signal from the high-voltage bias for readout, which is then fed to the front-end board. The necessity to handle high voltage, manage a large channel count, and operate stably for 20 years imposes significant constraints on the physical design of the HVS. This paper serves as a comprehensive documentation of the HVS board: its role in the SPMT readout system, the challenges in its design, performance and reliability metrics, and the methods employed for production and quality control