Prediction of Appropriate Shocks Using 24-Hour Holter Variables and T-Wave Alternans After First Implantable Cardioverter-Defibrillator Implantation in Patients With Ischemic or Nonischemic Cardiomyopathy

Abstract

In patients treated with implantable cardioverter defibrillator (ICD), prediction of both overall survival and occurrence of shocks is important if improved patient selection is desired. We prospectively studied the predictive value of biomarkers and indexes of cardiac and renal function and spectral microvolt T-wave alternans testing and 24-hour Holier variables in a population who underwent first ICD implantation. Consecutive patients in sinus rhythm with ischemic or dilated cardiomyopathy scheduled for primary or secondary prophylactic ICD implantation were enrolled. Exercise microvolt T-wave alternans and 24-hour Holler for number of ventricular premature contractions (VPCs), deceleration capacity, heart rate variability, and heart rate turbulence were done. Death of any cause and first appropriate ICD shock were defined as end points. Over 33 +/- 15 months of follow-up, 36 of 253 patients (14%) received appropriate shocks and 39 of 253 patients (15%) died. Only 3 of 253 patients (1%) died after receiving at least 1 appropriate shock. In univariate analyses, New York Heart Association class, ejection fraction, N-terminal pro brain-type natriuretic peptide (NT-proBNP), renal function, ICD indication, deceleration capacity, heart rate variability, and heart rate turbulence were predictive of all-cause mortality and VPC number and deceleration capacity predicted first appropriate shock. NT-proBNP (>= 1,600 pg/ml) was identified as the only independent predictor of all-cause mortality (hazard ratio 3.0, confidence interval 1.3 to 7.3, p = 0.014). In contrast, VPC number predicted appropriate shocks (hazard ratio 2.3, confidence interval 1.0 to 5.5, p = 0.047) as the only independent risk marker. In conclusion, NT-proBNP is a strong independent predictor of mortality in a typical prospective cohort of newly implanted patients with ICD, among many electrocardiographic and clinical variables studied. Number of VPCs was identified as a predictor of appropriate shocks (clinicaltrials.gov: NCT02010515). (C) 2016 The Authors. Published by Elsevier Inc. This is an open access article under the CC BY NC -ND license (http://creativecommons.orgflicenses/by-nc-nd/4.00. (Am J Cardiol 2016;118:86-94

Similar works

Full text

thumbnail-image

University of Regensburg Publication Server

redirect
Last time updated on 28/03/2020

This paper was published in University of Regensburg Publication Server.

Having an issue?

Is data on this page outdated, violates copyrights or anything else? Report the problem now and we will take corresponding actions after reviewing your request.