Variations of wettability and protein adsorption on solid siliceous carriers grafted with poly(N-isopropylacrylamide)

Abstract

Poly(N-isopropylacrylamide), a thermally responsive polymer, was end-grafted to mercaptopropyl derivatives of silica gel, plane glass sheets and glass capillary tubing by free radical polymerization of the monomer in 1,4-dioxane at 100 degrees C. The polymer monolayer attached to the glass carriers provided them with thermally controlled wettability registered by two independent methods: direct measurements of the water contact angle and capillary rise. The water Contact angle changed from 54 +/- 3 degrees to 68 +/- 3 degrees in the temperature range from 20 to 50 degrees C. The polymer grafting to silica gel (pore diameter 100 A, particle size 5 pm) resulted in 15-30-fold reduction in protein adsorption on the carrier at 35 degrees C. Adsorption isotherms of myoglobin indicate completely different characters of the protein adsorption to silica gel and its polyNIPAM-grafted derivative. Cooling of the grafted carrier containing adsorbed myoglobin to 9 degrees C led to a partial release of the protein to the contacting solution, whereas heating of the system to 35 degrees C resulted in reversible binding of the protein. Adsorption of myoglobin on polyNIPAM-coated silica was ca. 2-fold higher at 35 than at 9 degrees C, most probably (c) 2005 Elsevier Inc. All rights reserved

Similar works

Full text

thumbnail-image

Lund University Publications

redirect
Last time updated on 18/06/2017

This paper was published in Lund University Publications.

Having an issue?

Is data on this page outdated, violates copyrights or anything else? Report the problem now and we will take corresponding actions after reviewing your request.