research

Stone masonry buildings: shaking table testing and advanced methods of analysis

Abstract

The paper presents the main results of experimental tests concerning the reduction of the seismic vulnerability of stone masonry buildings with flexible floors. Two mock-ups (original condition and repaired) were tested in a 3D shaking table. The results show that the adopted measures are efficient. A set of non-linear static analyses (pushover) were considered, together with time integration analysis. The non-linear dynamic analyses reproduced the seismic behavior observed in the seismic tests. However, the pushover analyses did not simulate correctly all the failure mode of the structure and should be used with caution.This work was partly funded by project FP7-ENV-2009-1-244123-NIKER of the 7th Framework Programme of the European Commission Project

    Similar works