Abstract

The purpose of this study was to compare refractions measured with an autorefractor and retinoscopy in cycloplegic and non-cycloplegic eyes. The objective refractions were performed in 199 right eyes from 199 healthy young adults with a mean age of 21.6 ±2.66 years. The measurements were performed first without cycloplegia and repeated 30 minutes later with cycloplegia. Data were analyzed using Fourier decomposition of the power profile. More negative values of component M and J0 were give by non-cycloplegic autorefraction compared to cycloplegic autorefraction (p<0.001). However more positive values were given by non-cycloplegic autorefraciton regarding to the J45 vector, althought this differences were not statistically significant (p=0.233). Regarding retinoscopy, more negative values of component M where obtained with non-cycloplegic retinoscopy (p<0.001); for the cylindrical vectors J0 and J45 the retinoscopy without cycloplegic yields more negative values (p= 0.234; p= 0.112, respectively). Accepting that differences between cycloplegic and non-cycloplegic retinoscopy are only due to accommodative response, present results confirm that when performed by an experienced clinician, retinoscopy is a more reliable method to obtain objective start point for refraction under non-cycloplegic conditions

    Similar works