We have implemented a novel scheme of signal readout for resonant
gravitational wave detectors. For the first time, a capacitive resonant
transducer has been matched to the signal amplifier by means of a tuned high Q
electrical resonator. The resulting 3-mode detection scheme widens
significantly the bandwidth of the detector. We present here the results
achieved by this signal readout equipped with a two-stage SQUID amplifier. Once
installed on the AURIGA detector, the one-sided spectral sensitivity obtained
with the detector operated at 4.5 K is better than 10^-20 Hz^-1/2 over 110 Hz
and in good agreement with the expectations.Comment: 17 pages, 4 figure