International audienceIn order to develop our knowledge of the relations between the high degree of protectiveness of passive layers and their composition, corroded archaeological bronzes of Bronze Age (1500-950 BC) have been characterised by different methods of analysis. Results reveal that the passive layers have a bilayer structure and are due to the selective dissolution of copper from the copper solid solution of the alloy to the electrolyte. For all of the objects, the ratio [(Sn/Cu)p / (Sn/ Cu)a], with p for the outermost passive layer and a the alloy, has about the same value. Sn concentration within outermost passive layers is discussed in relation with the theoretical implications of the Kirchheim model