We observe individual tunnel events of a single electron between a quantum
dot and a reservoir, using a nearby quantum point contact (QPC) as a charge
meter. The QPC is capacitively coupled to the dot, and the QPC conductance
changes by about 1% if the number of electrons on the dot changes by one. The
QPC is voltage biased and the current is monitored with an IV-convertor at room
temperature. We can resolve tunnel events separated by only 8 μs, limited
by noise from the IV-convertor. Shot noise in the QPC sets a 25 ns lower bound
on the accessible timescales.Comment: 3 pages, 3 figures, submitte