CORE
🇺🇦
make metadata, not war
Services
Services overview
Explore all CORE services
Access to raw data
API
Dataset
FastSync
Content discovery
Recommender
Discovery
OAI identifiers
OAI Resolver
Managing content
Dashboard
Bespoke contracts
Consultancy services
Support us
Support us
Membership
Sponsorship
Community governance
Advisory Board
Board of supporters
Research network
About
About us
Our mission
Team
Blog
FAQs
Contact us
Short-term ventricular restraint attenuates post-infarction remodeling in rats
Authors
,
S Agathopoulos
+11 more
K Dimos
TM Kolettis
ES Lampri
V Malamou-Mitsi
P Mantzouratou
I Mourouzis
DL Oikonomidis
C Pantos
A Papalois
N Tsitou
AD Vilaeti
Publication date
10 May 2013
Publisher
Abstract
Background/objectives: Left ventricular restraint attenuates post-infarction remodeling, but may be associated with unfavorable long-term histological response. We hypothesized that beneficial effects can be obtained with short-term restraint during the early post-infarction period; for this purpose, we evaluated a biodegradable scaffold in the in vivo rat model and compared it with epicardial hydrogel application. Methods: A total of 230 Wistar rats (358 ± 7 g) were studied. Implantation was performed with and without prior myocardial infarction, induced by permanent coronary artery ligation. Diastolic filling was evaluated by left ventricular pressure recordings after scaffold implantation. Degradation rates and inflammatory/foreign body response were studied at 3, 7 and 15 days post-ligation. Remodeling indices were evaluated by echocardiography 15 days post-ligation. Results: No differences were found in diastolic pressure. Biodegradability was ~ 50% by 7 days and 100% by 15 days for both materials. Likewise, inflammatory/foreign body response peaked at 3 days post-implant, with subsequent remission, but fibroblastic reaction was more pronounced after scaffold than after hydrogel implantation. Post-ligation, ejection fraction was higher in the scaffold (40.0 ± 1.5%) or hydrogel groups (37.0 ± 1.3%), compared to controls (30.6 ± 1.9%). Wall tension index was lower with either biomaterial, but left ventricular end-diastolic diameter was shorter (p = 0.044) and sphericity was attenuated (p = 0.029) after scaffold, compared to hydrogel implantation. Conclusions: Both biomaterials showed a favorable histological response and attenuated remodeling, but epicardial restraint produced better results compared to hydrogel alone. The latter approach merits further investigation due to the ease of implantation. © 2012 Elsevier Ireland Ltd
Similar works
Full text
Available Versions
CUED - Cambridge University Engineering Department
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:generic.eprints.org:890938...
Last time updated on 15/07/2020