Abstract

PurposeThe National Cancer Institute Common Terminology Criteria for Adverse Events (CTCAE) v5.0 is the standard for oncology toxicity encoding and grading, despite limited validation. We assessed interrater reliability (IRR) in multireviewer toxicity identification.Methods and materialsTwo reviewers independently reviewed 100 randomly selected notes for weekly on-treatment visits during radiation therapy from the electronic health record. Discrepancies were adjudicated by a third reviewer for consensus. Term harmonization was performed to account for overlapping symptoms in CTCAE. IRR was assessed based on unweighted and weighted Cohen's kappa coefficients.ResultsBetween reviewers, the unweighted kappa was 0.68 (95% confidence interval, 0.65-0.71) and the weighted kappa was 0.59 (0.22-1.00). IRR was consistent between symptoms noted as present or absent with a kappa of 0.6 (0.66-0.71) and 0.6 (0.65-0.69), respectively.ConclusionsSignificant discordance suggests toxicity identification, particularly retrospectively, is a complex and error-prone task. Strategies to minimize IRR, including training and simplification of the CTCAE criteria, should be considered in trial design and future terminologies