Muscle models and animal observations suggest that physical damping is
beneficial for stabilization. Still, only a few implementations of mechanical
damping exist in compliant robotic legged locomotion. It remains unclear how
physical damping can be exploited for locomotion tasks, while its advantages as
sensor-free, adaptive force- and negative work-producing actuators are
promising. In a simplified numerical leg model, we studied the energy
dissipation from viscous and Coulomb damping during vertical drops with
ground-level perturbations. A parallel spring-damper is engaged between
touch-down and mid-stance, and its damper auto-disengages during mid-stance and
takeoff. Our simulations indicate that an adjustable and viscous damper is
desired. In hardware we explored effective viscous damping and adjustability
and quantified the dissipated energy. We tested two mechanical, leg-mounted
damping mechanisms; a commercial hydraulic damper, and a custom-made pneumatic
damper. The pneumatic damper exploits a rolling diaphragm with an adjustable
orifice, minimizing Coulomb damping effects while permitting adjustable
resistance. Experimental results show that the leg-mounted, hydraulic damper
exhibits the most effective viscous damping. Adjusting the orifice setting did
not result in substantial changes of dissipated energy per drop, unlike
adjusting damping parameters in the numerical model. Consequently, we also
emphasize the importance of characterizing physical dampers during real legged
impacts to evaluate their effectiveness for compliant legged locomotion