This paper reports the results of extensive wideband
channel measurements conducted on in-house outlets
at 10~30MHz. Two kinds of measurements were
performed: impulse response measurements and noise
measurements. Impulse responses were obtained in
two different time scales: 50 impulse responses taken
for 1 minute to see short term variation and for 6
milliseconds to see very short term variation. Noise
measurements were carried out to measure
background noise, appliance noise and periodic noise.
These measurements at a specific outlet are repeated
in every other hour over 24 hours. The measured data
were carefully reduced and analyzed to extract
relevant information to obtain time-varying channel
and noise characteristic for in-house power line
communication