Abstract

A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future lepton collider experiments. A prototype of 21.5 X0X_0 depth and 180×180180 \times 180 mm2^2 transverse dimensions was constructed, consisting of 2160 individually read out 10×45×310 \times 45 \times 3 mm3^3 scintillator strips. This prototype was tested using electrons of 2--32 GeV at the Fermilab Test Beam Facility in 2009. Deviations from linear energy response were less than 1.1\%, and the intrinsic energy resolution was determined to be (12.6±0.1(stat.)±0.4(syst.))%/E[GeV](1.1±0.1(stat.)0.7+0.6(syst.))%(12.6 \pm 0.1 (\mathrm{stat.}) \pm0.4 (\mathrm{syst.}))\%/\sqrt{E[\mathrm{GeV}]}\oplus (1.1 \pm 0.1(\mathrm{stat.})^{+0.6}_{-0.7}(\mathrm{syst.}))\%, where the uncertainties correspond to statistical and systematic sources, respectively