370-376In the
present study, AISI 8620, 52100 and 440C steels were plasma paste boronized (PPB)
by using 100% borax paste. PPB process was carried out in a dc plasma system at temperature of 700 and 800<span style="font-family:Symbol;
mso-ascii-font-family:" times="" new="" roman";mso-hansi-font-family:"times="" roman";="" mso-ansi-language:en-us;mso-char-type:symbol;mso-symbol-font-family:symbol"="" lang="EN-US">°C
for 3 and 5 h in a gas mixture of 70%H2-30%Ar under a constant
pressure of 4 mbar.
Wear tests of the bearing steels were performed using a ball-on-disc test
device. The applied loads on the ball were 5 and 20 N and the sliding time was
60 min for each test. Wear tests were carried out in the unlubricated and
lubrication conditions at room temperature in air. Wear volume of the disc
specimen was determined from the cross-sectional area of the wear track,
obtained perpendicularly to the sliding direction. Worn surfaces of the samples
were PPB characterized by scanning electron microscopy and the results were
compared with those obtained for plasma paste boronized specimens.
</span