Ultrasound Does Not Detect Acute Changes in Glycogen in Vastus Lateralis of Man.

Abstract

PURPOSE: To examine the validity of ultrasound (via cloud based software that measures pixilation intensity according to a scale of 0-100) to non-invasively assess muscle glycogen in human skeletal muscle. METHODS: In Study 1, 14 professional male rugby league players competed in an 80-minute competitive rugby league game. In Study 2 (in a randomized repeated measures design), 16 recreationally active males completed an exhaustive cycling protocol to deplete muscle glycogen followed by 36 hours of HIGH or LOW carbohydrate intake (8 v 3 g.kg body mass). In both studies, muscle biopsies and ultrasound scans were obtained from the vastus lateralis (at 50% of the muscle length) before and after match play in Study 1 and at 36 h after glycogen depletion in Study 2. RESULTS: Despite match play reducing (P0.05) were present between changes in muscle glycogen concentration and changes in ultrasound scores. CONCLUSION: Data demonstrate that ultrasound (as based on measures of pixilation intensity) is not valid to measure muscle glycogen status within the physiological range (i.e. 200-500 mmol.kg dw) that is applicable to exercise-induced muscle glycogen utilization and post-exercise muscle glycogen re-synthesis