Thermal analysis of a plastic helical coil heat exchanger for a domestic water storage tank

Abstract

In the present study, the heat transfer coefficients of helically coiled corrugated plastic tube heat exchanger inside of the solar boiler vessel were investigated experimentally. The metal coil of the conventional solar boiler for domestic usage was replaced by a plastic tube and the results were compared with the numerical simulation and the technical documentation of the initial solar boiler. All the required parameters like inlet and outlet temperatures of tubeside and stratified temperatures, flow rate of fluids, etc. were measured using appropriate instruments. The test runs were performed for different temperatures inside the tank ranging from 30-60°C and different flow rates from which the heat transfer coefficients were calculated