Abstract

The Electron Counting Capacitance Standard currently pursued at PTB aims to close the Quantum Metrological Triangle with a final precision of a few parts in 10^7. This paper reports the considerable progress recently achieved with a new generation of single-electron tunnelling devices. A five-junction R-pump was operated with a relative charge transfer error of five electrons in 10^7, and was used to successfully perform single-electron charging of a cryogenic capacitor. The preliminary result for the single-electron charge quantum has an uncertainty of less than two parts in 10^6 and is consistent with the value of the elementary charge.Comment: 16 pages, 9 figures, 1 tabl

    Similar works

    Full text

    thumbnail-image

    Available Versions