Characterization of the diffusion coefficient of blood.
Authors
Atlas SW
Barth M
Goethe JW
McGeown JG
Publication date
1 May 2018
Publisher
'Wiley'
Doi
Cite
Abstract
PurposeTo characterize the diffusion coefficient of human blood for accurate results in intravoxel incoherent motion imaging.MethodsDiffusion-weighted MRI of blood samples from 10 healthy volunteers was acquired with a single-shot echo-planar-imaging sequence at body temperature. Effects of gradient profile (monopolar or flow-compensated), diffusion time (40-100 ms), and echo time (60-200 ms) were investigated.ResultsAlthough measured apparent diffusion coefficients of blood were larger for flow-compensated than for monopolar gradients, no dependence of the apparent diffusion coefficient on the diffusion time was found. Large differences between individual samples were observed, with results ranging from 1.26 to 1.66 µm2 /ms for flow-compensated and 0.94 to 1.52 µm2 /ms for monopolar gradients. Statistical analysis indicates correlations of the flow-compensated apparent diffusion coefficient with hematocrit (P = 0.007) and hemoglobin (P = 0.017), but not with mean corpuscular volume (P = 0.64). Results of Monte-Carlo simulations support the experimental observations.ConclusionsMeasured blood apparent diffusion coefficient values depend on hematocrit/hemoglobin concentration and applied gradient profile due to non-Gaussian diffusion. Because in vivo measurement is delicate, an estimation based on blood count results could be an alternative. For intravoxel incoherent motion modeling, the use of a blood self-diffusion constant Db = 1.54 ± 0.12 µm2 /ms for flow-compensated and Db = 1.30 ± 0.18 µm2 /ms for monopolar encoding is suggested. Magn Reson Med 79:2752-2758, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited
Similar works
Full text
Open in the Core reader
Download PDF
Available Versions
Institute of Cancer Research Repository
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:https://repository.icr.ac....
Last time updated on 10/10/2024
Crossref
See this paper in CORE
Go to the repository landing page
Download from data provider
info:doi/10.1002%2Fmrm.26919
Last time updated on 11/12/2019