CORE
🇺🇦
make metadata, not war
Services
Services overview
Explore all CORE services
Access to raw data
API
Dataset
FastSync
Content discovery
Recommender
Discovery
OAI identifiers
OAI Resolver
Managing content
Dashboard
Bespoke contracts
Consultancy services
Support us
Support us
Membership
Sponsorship
Community governance
Advisory Board
Board of supporters
Research network
About
About us
Our mission
Team
Blog
FAQs
Contact us
research
Sodium (Na) ultra-short echo time imaging in the human brain using a 3D-Cones trajectory
Authors
M Clemence
X Golay
+4 more
F Riemer
BS Solanky
C Stehning
CAM Wheeler-Kingshott
Publication date
1 February 2014
Publisher
Abstract
Object: Sodium magnetic resonance imaging (Na-MRI) of the brain has shown changes in Na signal as a hallmark of various neurological diseases such as stroke, Alzheimer's disease, Multiple Sclerosis and Huntington's disease. To improve scan times and image quality, we have implemented the 3D-Cones (CN) sequence for in vivo Na brain MRI. Materials and methods: Using signal-to-noise (SNR) as a measurement of sequence performance, CN is compared against more established 3D-radial k-space sampling schemes featuring cylindrical stack-of-stars (SOS) and 3D-spokes kooshball (KB) trajectories, on five healthy volunteers in a clinical setting. Resolution was evaluated by simulating the point-spread-functions (PSFs) and experimental measures on a phantom. Results: All sequences were shown to have a similar SNR arbitrary units (AU) of 6-6.5 in brain white matter, 7-9 in gray matter and 17-18 AU in cerebrospinal fluid. SNR between white and gray matter were significantly different for KB and CN (p = 0.046 and <0.001 respectively), but not for SOS (p = 0.1). Group mean standard deviations were significantly smaller for CN (p = 0.016). Theoretical full-width at half-maximum linewidth of the PSF for CN is broadened by only 0.1, compared to 0.3 and 0.8 pixels for SOS and KB respectively. Actual image resolution is estimated as 8, 9 and 6.3 mm for SOS, KB and CN respectively. Conclusion: The CN sequence provides stronger tissue contrast than both SOS and KB, with more reproducible SNR measurements compared to KB. For CN, a higher true resolution in the same amount of time with no significant trade-off in SNR is achieved. CN is therefore more suitable for Na-MRI in the brain. © 2013 The Author(s)
Similar works
Full text
Open in the Core reader
Download PDF
Available Versions
UCL Discovery
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:eprints.ucl.ac.uk.OAI2:142...
Last time updated on 21/03/2014