We have recently completed a 64-night spectroscopic monitoring campaign at
the Lick Observatory 3-m Shane telescope with the aim of measuring the masses
of the black holes in 12 nearby (z < 0.05) Seyfert 1 galaxies with expected
masses in the range ~10^6-10^7M_sun and also the well-studied nearby active
galactic nucleus (AGN) NGC 5548. Nine of the objects in the sample (including
NGC 5548) showed optical variability of sufficient strength during the
monitoring campaign to allow for a time lag to be measured between the
continuum fluctuations and the response to these fluctuations in the broad
Hbeta emission, which we have previously reported. We present here the light
curves for the Halpha, Hgamma, HeII 4686, and HeI 5876 emission lines and the
time lags for the emission-line responses relative to changes in the continuum
flux. Combining each emission-line time lag with the measured width of the line
in the variable part of the spectrum, we determine a virial mass of the central
supermassive black hole from several independent emission lines. We find that
the masses are generally consistent within the uncertainties. The time-lag
response as a function of velocity across the Balmer line profiles is examined
for six of the AGNs. Finally we compare several trends seen in the dataset
against the predictions from photoionization calculations as presented by
Korista & Goad. We confirm several of their predictions, including an increase
in responsivity and a decrease in the mean time lag as the excitation and
ionization level for the species increases. Further confirmation of
photoionization predictions for broad-line gas behavior will require additional
monitoring programs for these AGNs while they are in different luminosity
states. [abridged]Comment: 37 pages, 18 figures and 15 tables, accepted for publication in the
Astrophysical Journa