This article analyzes the application of dynamic compaction, vibroflotation and vibroreplacement (stone columns) to liquefaction prevention. The ground types to which they can be applied, the depths that can be reached and the degree of improvement that can be obtained are all studied. Finally, and on the basis of the above, basic guidelines are given for the design of ground improvement with these techniques and for the aforementioned purpose