DESINFECÇÃO DE EFLUENTE SECUNDÁRIO DO SISTEMA UASB + WETLAND

Abstract

This work assessed the applicability of UV/TiO2/O3 processes in photo reactors column type for disinfection of secondary effluents of ETE pilot UASB + Wetland of UNISC. The reactors were tested with the same detention times of 0 to 60 minutes, both fed with the studied secondary effluents in pH=7. The tests were carried out with a recirculation time of 1 hour, flow of 180 L h-1, germicide lamps of 30W. The obtained results showed the applicability of the reactors type column for disinfection of treated sewage, obtained total disinfection in HDT’s of 12 minutes, from the inactivation of thermo-tolerant coliforms. Also, the experiments using the UV/TiO2/O3 process had demonstrated to greater capacity of oxidation in function of the reductions of total alkalinity and turbidity, indicating major potentialities for the disinfection.Este trabalho avaliou a aplicabilidade do processo UV/TiO2/O3 em reator tipo coluna para desinfecção de efluentes secundários da ETE piloto UASB + Wetland da UNISC. O reator foi testado de 0 a 60 minutos, alimentado com os efluentes secundários estudados em pH=7,0. Os ensaios foram realizados com tempo de recirculação de 1 hora, vazão de 180 L h –1 e lâmpadas germicidas de 30 W. Os resultados obtidos demonstraram a aplicabilidade do reator tipo coluna para desinfecção de esgotos tratados, sendo obtida desinfecção total em tempos de detenção hidráulica de 12 minutos, a partir das inativações de coliformes termotolerantes. Também, os experimentos utilizando o processo UV/TiO2/O3 demonstraram maior capacidade de oxidação em função das reduções da alcalinidade total e turbidez, indicando maiores potencialidades para a desinfecção

    Similar works