A Simple Control to Reduce the Voltage Stress of Non-Conducting Switches in Three-Level ANPC Converter

Abstract

With the development of wide band-gap (WBG) technology, the switching speed of power semiconductor devices is increased, which makes circuits more sensitive to parasitics. For three-level active neutral point clamped (3L-ANPC) converters, the over-voltage of non-conducting switches can be an issue. This paper analyzes the multiple commutation loops in 3L-ANPC converter and summarizes the impact factors of the over-voltage for the non-conducting switch. It is found that the nonlinearity of the output capacitance of the device can significantly influence the over-voltage. A simple control without introducing any additional hardware circuit is proposed to attenuate the impact of the nonlinearity. With the proposed control, the peak over-voltage of the non-conducting switch can be reduced significantly. Multi-pulse test is conducted for a 3L- ANPC converter built with silicon carbide (SiC) MOSFETs. The testing results show that the peak over-voltage decreases from 892 V to 624 V with the proposed control. More detailed analysis and experimental results will be provided in the final paper

    Similar works