CORE
CO
nnecting
RE
positories
Services
Services overview
Explore all CORE services
Access to raw data
API
Dataset
FastSync
Content discovery
Recommender
Discovery
OAI identifiers
OAI Resolver
Managing content
Dashboard
Bespoke contracts
Consultancy services
Support us
Support us
Membership
Sponsorship
Research partnership
About
About
About us
Our mission
Team
Blog
FAQs
Contact us
Community governance
Governance
Advisory Board
Board of supporters
Research network
Innovations
Our research
Labs
Learning from data: Recognizing glaucomatous defect patterns and detecting progression from visual field measurements
Authors
M Balasubramanian
C Bowd
+7 more
CA Girkin
MH Goldbaum
JM Liebmann
FA Medeiros
RN Weinreb
S Yousefi
LM Zangwill
Publication date
1 January 2014
Publisher
eScholarship, University of California
Doi
Abstract
A hierarchical approach to learn from visual field data was adopted to identify glaucomatous visual field defect patterns and to detect glaucomatous progression. The analysis pipeline included three stages, namely, clustering, glaucoma boundary limit detection, and glaucoma progression detection testing. First, cross-sectional visual field tests collected from each subject were clustered using a mixture of Gaussians and model parameters were estimated using expectation maximization. The visual field clusters were further estimated to recognize glaucomatous visual field defect patterns by decomposing each cluster into several axes. The glaucoma visual field defect patterns along each axis then were identified. To derive a definition of progression, the longitudinal visual fields of stable glaucoma eyes on the abnormal cluster axes were projected and the slope was approximated using linear regression (LR) to determine the confidence limit of each axis. For glaucoma progression detection, the longitudinal visual fields of each eye on the abnormal cluster axes were projected and the slope was approximated by LR. Progression was assigned if the progression rate was greater than the boundary limit of the stable eyes; otherwise, stability was assumed. The proposed method was compared to a recently developed progression detection method and to clinically available glaucoma progression detection software. The clinical accuracy of the proposed pipeline was as good as or better than the currently available methods. © 1964-2012 IEEE
Similar works
Full text
Open in the Core reader
Download PDF
Available Versions
DIALNET
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:dialnet.unirioja.es:ART000...
Last time updated on 20/08/2019
Universidad Nacional de Trujillo: Publicaciones Científicas
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:ojs.revistas.unitru.edu.pe...
Last time updated on 15/12/2019
Crossref
See this paper in CORE
Go to the repository landing page
Download from data provider
info:doi/10.1109%2Ftbme.2014.2...
Last time updated on 01/04/2019